Mass attenuation coefficient of saccharides for X-rays in the energy range from 8 keV to 32 keV

被引:17
|
作者
Kerur, B. R. [1 ]
Manjula, V. T. [1 ]
Lagare, M. T. [1 ]
Kumar, S. Anil [2 ]
机构
[1] Gulbarga Univ, Dept Phys, Gulbarga 585106, Karnataka, India
[2] Bhabha Atom Res Ctr, Radiat Safety Syst Div, Bombay 400085, Maharashtra, India
关键词
Mass attenuation coefficients; Saccharides; Photoelectric; X-rays; Photon cross sections; Bragg's additivity law; CROSS-SECTIONS;
D O I
10.1016/j.radmeas.2008.11.003
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Mass attenuation coefficients have been measured for mono and disaccharides at photon energies 8.136, 13.596, 17.781, 22.581 and 32.890 keV. The measured values are compared with the computed values obtained using personal computer software package WinXCOM. The agreement between the two is within -5.3% to 3%. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 47 条
  • [1] Measurement of mass attenuation coefficients for four mixtures using X-rays from 13 keV up to 40 keV
    Angelone, M
    Esposito, A
    Chiti, M
    Gentile, A
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 547 - 548
  • [2] Measurement of the mass attenuation coefficient for elemental materials in the range 6 ≤, Z ≤ 82 using X-rays from 13 up to 50 kev
    Angelone, M
    Bubba, T
    Esposito, A
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 505 - 511
  • [3] Nonabelian dark matter models for 3.5 keV X-rays
    Cline, James M.
    Frey, Andrew R.
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2014, (10):
  • [4] Measurement of the x-ray mass attenuation coefficients of gold in the 38-50-keV energy range
    Islam, M. T.
    Rae, N. A.
    Glover, J. L.
    Barnea, Z.
    de Jonge, M. D.
    Tran, C. Q.
    Wang, J.
    Chantler, C. T.
    PHYSICAL REVIEW A, 2010, 81 (02):
  • [5] Nonthermal X-rays from low-energy cosmic rays: application to the 6.4 keV line emission from the Arches cluster region
    Tatischeff, V.
    Decourchelle, A.
    Maurin, G.
    ASTRONOMY & ASTROPHYSICS, 2012, 546
  • [6] Measurement of X-ray mass attenuation coefficients in biological and geological samples in the energy range of 7-12 keV
    Trunova, Valentina
    Sidorina, Anna
    Kriventsov, Vladimir
    APPLIED RADIATION AND ISOTOPES, 2015, 95 : 48 - 52
  • [7] Gamma ray attenuation parameters of inorganic nonlinear optical materials in the energy range 122 keV to 1330 keV
    Awasarmol, Vishal Vishwanath
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2017, 55 (01) : 65 - 72
  • [8] Measurement of the X-ray mass attenuation coefficients of silver in the 5-20 keV range
    Islam, M. Tauhidul
    Tantau, Lachlan J.
    Rae, Nicholas A.
    Barnea, Zwi
    Tran, Chanh Q.
    Chantler, Christopher T.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 413 - 423
  • [9] On amplitude beam splitting of tender X-rays (2-8 keV photon energy) using conical diffraction from reflection gratings with laminar profile
    Jark, Werner
    Eichert, Diane
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 91 - 97
  • [10] High accuracy experimental determination of copper and zinc mass attenuation coefficients in the 100 eV to 30 keV photon energy range
    Menesguen, Y.
    Gerlach, M.
    Pollakowski, B.
    Unterumsberger, R.
    Haschke, M.
    Beckhoff, B.
    Lepy, M-C
    METROLOGIA, 2016, 53 (01) : 7 - 17