Echo-doppler-flowmetric assessment of penile dorsal arteries and their role in the erectile mechanism

被引:5
作者
Barra, S
Iacono, F
机构
[1] Urologic Clinic School of Medicine, University of Naples, FEDERICO II, Naples
关键词
impotence; penile erection; ultrasonography; blood flow velocity;
D O I
10.1016/S0720-048X(96)01084-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-doppler-flowmetric investigation is the best non-invasive technique for evaluating vascular dynamics of the erection mechanism. Previous studies were carried out with the aim of obtaining some reference parameters for healthy subjects and for subjects affected by impotence with different etiology. All of these studies focused on the penile cavernous artery, neglecting the role played by the penile dorsal artery in the erection process. In this study we examined the flowmetric pattern of the penile dorsal artery before and after intracavernous injection of PGE1 10 mu g. A significant increase in the velocity of systolic and diastolic velocity was observed in dorsal arteries after intracavernous injection (P < 0.0001) in control subjects and in non-arteriogenic impotent patients. Moreover, the systolic velocity of dorsal arteries presents, after pharmacological stimulation, a statistically significant difference in comparison to the homolateral cavernous artery in non-arteriogenic impotent patients and in healthy subjects. In patients with arterial insufficiency, the absence of the dorsal artery was observed in 5 cases. Furthermore, the systolic velocity of dorsal arteries turns out to be significantly lower than the systolic velocity of dorsal arteries in normal subjects; it is, however, higher than the reference standard for arteriogenic impotent patients. II is likely that the penile dorsal artery, because of its extensive vascular connections with the cavernous artery, provides a hemodynamic support, which can counterbalance slight disorders of cavernous arteries. When the dorsal artery is absent (agenesis, aplasia), or diseased, even slight alterations can result in an early onset of erectile insufficiency. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 11 条
[1]  
ABOSEIF SR, 1988, UROL CLIN N AM, V15, P1
[2]   ASSESSMENT OF BLOOD-FLOW IN DIFFERENT SEGMENTS OF THE PENIS BY DUPLEX SONOGRAPHY IN SUBJECTS WITH NORMAL ERECTILE POTENCY [J].
BARRA, S ;
IACONO, F .
EUROPEAN JOURNAL OF RADIOLOGY, 1994, 19 (01) :60-64
[3]   APPLICATION OF COMPUTERIZED PENILE ARTERIAL WAVE-FORM ANALYSIS IN THE DIAGNOSIS OF ARTERIOGENIC IMPOTENCE - AN INITIAL STUDY IN POTENT AND IMPOTENT MEN [J].
DESAI, KM ;
GINGELL, JC ;
SKIDMORE, R ;
FOLLETT, DH .
BRITISH JOURNAL OF UROLOGY, 1987, 60 (05) :450-456
[4]  
GOLD I, 1987, NEW YORK TIMES BK R, P18
[5]   EVALUATION OF PENILE DEEP ARTERIES IN PSYCHOGENIC IMPOTENCE BY MEANS OF DUPLEX ULTRASONOGRAPHY [J].
IACONO, F ;
BARRA, S ;
LOTTI, T .
JOURNAL OF UROLOGY, 1993, 149 (05) :1262-1264
[6]  
KESSLER WO, 1988, UROL CLIN N AM, V15, P81
[7]   VASCULOGENIC IMPOTENCE EVALUATED BY HIGH-RESOLUTION ULTRASONOGRAPHY AND PULSED DOPPLER SPECTRUM ANALYSIS [J].
LUE, TF ;
HRICAK, H ;
MARICH, KW ;
TANAGHO, EA .
RADIOLOGY, 1985, 155 (03) :777-781
[8]  
LUE TF, 1988, CONT MANAGEMENT IMPO, P57
[9]   PREOPERATIVE ASSESSMENT OF PEYRONIES DISEASE USING COLOR DOPPLER SONOGRAPHY [J].
RALPH, DJ ;
HUGHES, T ;
LEES, WR ;
PRYOR, JP .
BRITISH JOURNAL OF UROLOGY, 1992, 69 (06) :629-632
[10]  
SEOUNG IG, 1990, INT J IMPOTENCE R S1, V2, P121