Design and Haemodynamic Analysis of a Novel Anchoring System for Central Venous Pressure Measurement

被引:3
|
作者
Manavi, Tejaswini [1 ,2 ]
Ijaz, Masooma [1 ,2 ]
O'Grady, Helen [1 ,2 ]
Nagy, Michael [3 ]
Martina, Jerson [3 ]
Finucane, Ciaran [4 ]
Sharif, Faisal [1 ,2 ,5 ,6 ]
Zafar, Haroon [1 ,2 ,7 ]
机构
[1] Univ Galway, Cardiovasc Res & Innovat Ctr, Galway H91 TK33, Ireland
[2] Univ Galway, Sch Med, Lambe Inst Translat Res, Galway H91 TK33, Ireland
[3] Endotronix Inc, Lisle, IL 60532 USA
[4] St Jamess Hosp Dublin, Dept Med Phys & Bioengn, Mercers Inst Successful Ageing, Dublin D08 NHY1, Ireland
[5] Univ Hosp Galway, Dept Cardiol, Galway H91 YR71, Ireland
[6] BioInnovate, Galway H91 TK33, Ireland
[7] Univ Galway, Coll Sci & Engn, Galway H91 TK33, Ireland
基金
爱尔兰科学基金会;
关键词
central venous pressure; heart failure; remote patient management; wireless pressure sensor; inferior vena cava; anchoring system; haemodynamic analysis; bench testing; computational fluid dynamics; ACUTE HEART-FAILURE; VENA-CAVA FILTERS; CRITICALLY-ILL; STENT; HOSPITALIZATIONS; COMPLICATIONS; MECHANISMS; THROMBOSIS; CATHETERS; DISEASE;
D O I
10.3390/s22218552
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background/Objective: In recent years, treatment of heart failure patients has proved to benefit from implantation of pressure sensors in the pulmonary artery (PA). While longitudinal measurement of PA pressure profoundly improves a clinician's ability to manage HF, the full potential of central venous pressure as a clinical tool has yet to be unlocked. Central venous pressure serves as a surrogate for the right atrial pressure, and thus could potentially predict a wider range of heart failure conditions. However, it is unclear if current sensor anchoring methods, designed for the PA, are suitable to hold pressure sensors safely in the inferior vena cava. The purpose of this study was to design an anchoring system for accurate apposition in inferior vena cava and evaluate whether it is a potential site for central venous pressure measurement. Materials and Methods: A location inferior to the renal veins was selected as an optimal site based on a CT scan analysis. Three anchor designs, a 10-strut anchor, and 5-struts with and without loops, were tested on a custom-made silicone bench model of Vena Cava targeting the infra-renal vena cava. The model was connected to a pulsatile pump system and a heated water bath that constituted an in-vitro simulation unit. Delivery of the inferior vena cava implant was accomplished using a preloaded introducer and a dilator as a push rod to deploy the device at the target area. The anchors were subjected to manual compression tests to evaluate their stability against dislodgement. Computational Fluid Dynamics (CFD) analysis was completed to characterize blood flow in the anchor's environment using pressure-based transient solver. Any potential recirculation zones or disturbances in the blood flow caused by the struts were identified. Results: We demonstrated successful anchorage and deployment of the 10-strut anchor in the Vena Cava bench model. The 10-strut anchor remained stable during several compression attempts as compared with the other two 5-strut anchor designs. The 10-strut design provided the maximum number of contact points with the vessel in a circular layout and was less susceptible to movement or dislodgement during compression tests. Furthermore, the CFD simulation provided haemodynamic analysis of the optimum 10-strut anchor design. Conclusions: This study successfully demonstrated the design and deployment of an inferior vena cava anchoring system in a bench test model. The 10-strut anchor is an optimal design as compared with the two other 5-strut designs; however, substantial in-vivo experiments are required to validate the safety and accuracy of such implants. The CFD simulation enabled better understanding of the haemodynamic parameters and any disturbances in the blood flow due to the presence of the anchor. The ability to place a sensor technology in the vena cava could provide a simple and minimally invasive approach for heart failure patients.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] A technique for central venous pressure measurement in normal horses
    Wilsterman, Sonya
    Hackett, Eileen S.
    Rao, Sangeeta
    Hackett, Timothy B.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2009, 19 (03) : 241 - 246
  • [32] Relevance of type of catheters for central venous pressure measurement
    Santelices, S
    Sullivan, KJ
    Kissoon, N
    Duckworth, LJ
    Murphy, SP
    PEDIATRIC EMERGENCY CARE, 2004, 20 (07) : 448 - 452
  • [33] INACCURACIES IN MANOMETRIC CENTRAL VENOUS-PRESSURE MEASUREMENT
    CLAYTON, DG
    RESUSCITATION, 1988, 16 (03) : 221 - 230
  • [34] Central venous pressure: A useful but not so simple measurement
    Magder, Sheldon
    CRITICAL CARE MEDICINE, 2006, 34 (08) : 2224 - 2227
  • [35] CAVEATS ON ABDOMINAL CENTRAL VENOUS-PRESSURE MEASUREMENT
    TONG, TK
    PEDIATRICS, 1992, 90 (03) : 479 - 479
  • [36] IVC measurement for the noninvasive evaluation of central venous pressure
    Max Ruge
    Gregary D. Marhefka
    Journal of Echocardiography, 2022, 20 : 133 - 143
  • [37] RELIABLE PERCUTANEOUS CENTRAL VENOUS-PRESSURE MEASUREMENT
    VAUGHAN, RW
    WEYGANDT, GR
    ANESTHESIA AND ANALGESIA, 1973, 52 (05): : 709 - 716
  • [38] IVC measurement for the noninvasive evaluation of central venous pressure
    Ruge, Max
    Marhefka, Gregary D.
    JOURNAL OF ECHOCARDIOGRAPHY, 2022, 20 (03) : 133 - 143
  • [39] Non-Invasive Central Venous Pressure Measurement Using Enclosed-Zone Central Venous Pressure (ezCVP™)
    Hidaka, Takayuki
    Sumimoto, Yoji
    Dohi, Yoshihiro
    Morimoto, Haruka
    Susawa, Hitoshi
    Nitta, Kazuhiro
    Ishibashi, Ken
    Kurisu, Satoru
    Fukuda, Yukihiro
    Hashimoto, Haruki
    Matsui, Shogo
    Kishimoto, Shinji
    Kajikawa, Masato
    Maruhashi, Tatsuya
    Ukawa, Teiji
    Goto, Chikara
    Nakashima, Ayumu
    Noma, Kensuke
    Tsuji, Toshio
    Kihara, Yasuki
    Higashi, Yukihito
    CIRCULATION JOURNAL, 2020, 84 (07) : 1112 - 1117
  • [40] The design and analysis of a novel structural piezoresistive pressure sensor for low pressure measurement
    Chuang Li
    Francisco Cordovilla
    José L. Ocaña
    Microsystem Technologies, 2017, 23 : 5677 - 5687