Multiscale design of surface morphological gradient for osseointegration

被引:54
作者
Chen, Junning [1 ]
Rungsiyakull, Chaiy [1 ,2 ]
Li, Wei [1 ]
Chen, Yuhang [1 ,3 ]
Swain, Michael [4 ]
Li, Qing [1 ]
机构
[1] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Sydney, NSW 2006, Australia
[2] Chiang Mai Univ, Dept Mech Engn, Muang 50200, Thailand
[3] Heriot Watt Univ, Sch Engn & Phys Sci, Edinburgh EH14 4AS, Midlothian, Scotland
[4] Univ Sydney, Fac Dent, Sydney, NSW 2006, Australia
基金
澳大利亚研究理事会;
关键词
Osseointegration; Porous implant; Topography optimization; Multiscale modeling; Bone remodeling; Material design optimization; Finite element; FINITE-ELEMENT-ANALYSIS; POROUS TITANIUM; NUMERICAL-ANALYSIS; DENTAL IMPLANTS; BONE INGROWTH; OPTIMIZATION; MICROSTRUCTURE; OSTEOBLAST; ROUGHNESS; COATINGS;
D O I
10.1016/j.jmbbm.2012.08.019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rapid and stable osseointegration signifies a major concern in design of implantable prostheses, which stimulates continuous development of new implant materials and structures. This study aims to develop a graded configuration of a bead/particle coated porous surface for implants by exploring how its micromechanical features determine osseointegration through multiscale modeling and remodeling techniques. A typical dental implantation setting was exemplified for investigation by using the remodeling parameters determined from a systematic review of bone-implant-contact (BIG) ratio published in literature. The global responses of a macroscale model were obtained through 48 month remodeling simulation, which forms the basis for the 27 microscopic models created with different particle gradients ranging from 30 to 70 mu m. The osseointegration responses are evaluated in terms of the BIG ratio and the averaged 10% peak Tresca shear stress (PTS). Within the sampling designs considered, the configuration with 50-30-30 mu m particle sizes provides the best outcome, counting 20% more BIG ratio and 0.17 MPa less PTS compared with the worst case scenario, also outperforming the best uniform morphology of 70 gm particles. Furthermore, the response surface method (RSM) was utilized to formulate the bone remodeling responses in terms of gradient parameters across three layers. Gradient 30.0-30.0-32.1 is found an optimal gradient for BIG ratio, and 70-45.4-40.8 the best for the minimum PTS. The multiobjective optimization was finally performed to simultaneously maximize BIG ratio and minimize PTS for achieving the best possible overall outcome. Due to strong competition between these two design objectives, a Pareto front is generated. To make a proper trade-off, the minimum distance selection criterion is considered and the gradient of 37.1-70.0-67.7 appears an optimal solution. This study provides a novel surface configuration and design methodology for individual patient that allow optimizing topographical gradient for a desirable patient-specific biomechanical environment to promote osseointegration. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:387 / 397
页数:11
相关论文
共 63 条
[1]   Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model [J].
Abron, A ;
Hopfensperger, M ;
Thompson, J ;
Cooper, LF .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01) :40-46
[2]   Framework for optimal design of porous scaffold microstructure by computational simulation of bone regeneration [J].
Adachi, T ;
Osako, Y ;
Tanaka, M ;
Hojo, M ;
Hollister, SJ .
BIOMATERIALS, 2006, 27 (21) :3964-3972
[3]  
ANDERSON RC, 1984, CLIN ORTHOP RELAT R, P242
[4]  
Anil S, 2011, IMPLANT DENTISTRY - A RAPIDLY EVOLVING PRACTICE, P83
[5]  
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P263
[6]  
Bradley N, 2007, RESPONSE SURFACE MET, P36
[7]   Bone Remodelling in BioShape [J].
Buti, F. ;
Cacciagrano, D. ;
Corradini, F. ;
Merelli, E. ;
Tesei, L. ;
Pani, M. .
ELECTRONIC NOTES IN THEORETICAL COMPUTER SCIENCE, 2010, 268 :17-29
[8]   FIBRIN STRUCTURE AND CONCENTRATION ALTER CLOT ELASTIC-MODULUS BUT DO NOT ALTER PLATELET-MEDIATED FORCE DEVELOPMENT [J].
CARR, ME ;
CARR, SL .
BLOOD COAGULATION & FIBRINOLYSIS, 1995, 6 (01) :79-86
[9]   Characterization of functionally graded hydroxyapatite/titanium composite coatings plasma-sprayed on Ti alloys [J].
Chen, Chun-Cheng ;
Huang, Tsui-Hsien ;
Kao, Chia-Tze ;
Ding, Shinn-Jyh .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) :146-152
[10]   Microstructure design of biodegradable scaffold and its effect on tissue regeneration [J].
Chen, Yuhang ;
Zhou, Shiwei ;
Li, Qing .
BIOMATERIALS, 2011, 32 (22) :5003-5014