Effect of Different Irrigants on the Adhesive Interface and Influence on the Push Out Strength of Fiber Posts

被引:2
|
作者
Belizario, L. G. [1 ,2 ]
Piragine, T. L. [1 ,2 ]
Girotto, A. C. [1 ,2 ]
Gelio, M. B. [1 ,2 ]
Fernandez, E. [4 ,5 ,6 ]
Pereira, J. R. [3 ]
Kuga, M. C. [1 ,2 ]
机构
[1] UNESP, Araraquara Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
[2] 1680 Ctr, BR-14801903 Araraquara, SP, Brazil
[3] Sch Dent Chile, Dept Restorat Dent, Santiago, Chile
[4] Univ Chile, Fac Odontol, Dept Odontol Restauradora, Santiago, Chile
[5] Univ Autonoma Chile, Inst Ciencias Biomed, Providencia, Chile
[6] Olivos 943 Independence Santiago, Santiago, Chile
关键词
SMEAR LAYER REMOVAL; BOND STRENGTH; SODIUM-HYPOCHLORITE; SPACE PREPARATION; FINAL IRRIGATION; RESIN CEMENTS; BORIC-ACID; DENTIN; CHLORHEXIDINE; DEBRIS;
D O I
10.2341/21-038-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to evaluate the effects of a new irrigant solution on the post space cleaning and the adhesive resistance of fiber posts. Methods and Materials: Eighty roots of bovine teeth were randomly allocated into eight groups (n=10 for each group). Evaluations were performed in two different time points for each irrigant. The irrigants included a control group with distilled water (DW), 2.5% NaOCl and 17% EDTA (SH), 1% peracetic acid (PA), and 5% boric acid and 1% citric acid (EX). The time points were 24 hours (I-immediate) and 6 months (D-delayed). The push-out test was performed using a universal testing machine with a 5 kN load cell operating at a crosshead speed of 0.5 mm/minute. The dentinal cementation system was analyzed using a laser confocal microscope (LSM5, Zeiss, Jena, Germany), and incidence of residue on radicular dentin was evaluated by scanning electron microscopy (SEM). The incidence of residue was evaluated by the Kruskal-Wallis test and push-out bond strength and dentin penetrability were evaluated via a one-way analysis of variance (ANOVA) and Tukey tests (alpha=0.05). Results: The EX irrigation protocol demonstrated the lowest incidence of residue on the dentin surface (p<0.05), independently of the evaluated third. In the cervical and the middle post thirds, EXI, EXD, SHI, and SHD groups exhibited similar push-out bond strength values (p>0.05). EXI, EXD, PAI, and PAD exhibited the greatest dentinal penetrability of the cementation system in all the post thirds (p<0.05). Conclusions: A solution containing 5% boric acid and 1% citric acid can be a promising irrigant for radicular post space cleaning. It has adequate potential for cleaning the dentin surface without interfering with the adhesive interface between the dentin and the cementation system.
引用
收藏
页码:E211 / E221
页数:11
相关论文
共 50 条
  • [1] Effect of Dentin Irrigants on Push-Out Bond Strength in Resin Cementation Protocols for Fiber Posts in Endodontically Treated Teeth: An In Vitro Study
    Garcia-Varela, Sandra
    Ramos, Joao Carlos
    Ginzo-Villamayor, Maria Jose
    Castelo-Baz, Pablo
    Mendez-Diaz, Ramon
    Anache-D'Abate, Marcos Anibal
    Gancedo-Gancedo, Tania
    Ruiz-Pinon, Manuel
    Mareque-Bueno, Soledad
    Martin-Biedma, Benjamin Jose
    MATERIALS, 2024, 17 (06)
  • [2] The effect of different adhesive system applications on push-out bond strengths of glass fiber posts
    Kivanc, Bagdagul Helvacioglu
    Arisu, Hacer Deniz
    Uctasli, Mine Betul
    Okay, Tufan Can
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03) : 305 - 311
  • [3] The effect of luting cement thicknesses on the push-out bond strength of the fiber posts
    Ozcan, Erhan
    Cetin, Ali Riza
    Tuncdemir, Ali Riza
    Ulker, Mustafa
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (3-4) : 703 - 709
  • [4] Effect of different adhesion strategies on push-out bond strength of fiber reinforced composite posts
    Oskoee, Parnian Alizadeh
    Navimipour, Elmira Jafari
    Oskoee, Siavash Savadi
    Bahari, Mahmoud
    Pournaghiazar, Fatemeh
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (76): : 17593 - 17598
  • [5] Effect of different endodontic sealers and time of cementation on push-out bond strength of fiber posts
    Vilas-Boas, Danielle Araujo
    Grazziotin-Soares, Renata
    Ardenghi, Diego Machado
    Bauer, Jose
    de Souza, Patricia Oliveira
    de Miranda Candeiro, George Taccio
    Maia-Filho, Etevaldo Matos
    Carvalho, Ceci Nunes
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) : 1403 - 1409
  • [6] Effect of endodontic sealers on push-out bond strength of cemented fiber posts
    Al-Dwairi, Ziad Nawaf
    Aleisa, Khalil
    Lynch, Edward
    QUINTESSENCE INTERNATIONAL, 2015, 46 (04): : 299 - 307
  • [7] Influence of chemical irrigants on the tensile bond strength of an adhesive system used to cement glass fiber posts to root dentin
    Pelegrine, Rina Andrea
    De Martin, Alexandre Sigrist
    Cunha, Rodrigo Sanches
    Pelegrine, Andre Antonio
    da Silveira Bueno, Carlos Eduardo
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (05): : E73 - E76
  • [8] Effect of different root canal irrigants on push-out bond strength of two novel root-end filling materials
    Omar, Nada
    Abdelraouf, Rasha M.
    Hamdy, Tamer M.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [9] The effect of sodium hypochlorite and resin cement systems on push-out bond strength of cemented fiber posts
    Alkhudhairy, Fahad I.
    Bin-Shuwaish, Mohammed S.
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (04) : 905 - 910
  • [10] Influence of endodontic irrigants on bond strength of a self-etching adhesive
    Farina, Ana P.
    Cecchin, Doglas
    Barbizam, Joao V. B.
    Carlini-Junior, Bruno
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (01) : 26 - 30