Dual chamber pacing with a single-lead DDD pacing system

被引:4
作者
Naegeli, B [1 ]
Straumann, E
Gerber, A
Schuiki, E
Kunz, M
Niederhäuser, U
Bertel, O
机构
[1] Stadtspital Triemli, Dept Internal Med, Cardiac Unit, CH-8063 Zurich, Switzerland
[2] Stadtspital Triemli, Dept Cardiac Surg, CH-8063 Zurich, Switzerland
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 07期
关键词
DDD pacing; single lead;
D O I
10.1111/j.1540-8159.1999.tb00565.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The successful application of single-lead VDD pacing during the last few years hers generated the idea of single-lead DDD pacing: Preliminary data from several single-lead VDD studies attempting to pace the atrium by a floating atrial dipole are unsatisfactory, causing an unacceptably high current drain of the device. We studied thefeasibility as well as the short- and long-term stability of atrioventricular sequential pacing, using a new single-pass, tined DDD lead. In eight consecutive patients (age 73 +/- 16 years) with symptomatic higher degree A V block and intact sinus node function, this new single-pass DDD lead was implanted in combination with a. DDDR pacemaker. Correct VDD and DDD function wets studied at implantation; at discharge; and at 1, 3, and 6 months of follow-up. At implant, the atrial stimulation threshold was 0.6 +/- 0.2 V/0.5 ms. During follow-up, the atrial pacing thresholds in different everyday positions averaged 2.1 +/- 0.5 V at discharge, 2.9 +/- 0.5 V at 2 month, 3.8 +/- 0.4 V at 3 months, and 3.4 +/- 0.4 V at 6 months (pulse width always 0.5 ms). The measured P wave amplitude at implantation was 4.5 +/- 2.2 mV; during follow-up the telemetered atrial sensitivity thresholds averaged 2.2 +/- 0.3 mV. Phrenic nerve stimulation at high output pacing (5.0 V/0.5 ms) was observed in three (38%) patients at discharge and in one (13%) patient during follow-up; an intermittent unmeasurable atrial lead impedance at 3 and 6 months follow-up was documented in one (13%) patient. This study confirms the possibility of short- and long-term DDD pacing using a single-pass DDD lead. Since atrial stimulation thresholds are still relatively high compared to conventional dual-lead DDD pacing, further improvements of the atrial electrodes are desirable, enabling lower pacing thresholds and optimizing energy requirements as well as minimizing the potential disadvantage of phrenic nerve stimulation.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 19 条
  • [1] ITALIAN MULTICENTER STUDY ON A SINGLE LEAD VDD PACING SYSTEM USING A NARROW ATRIAL DIPOLE SPACING
    ANTONIOLI, GE
    ANSANI, L
    BARBIERI, D
    GUARDIGLI, G
    PERCOCO, GF
    TOSELLI, T
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1890 - 1893
  • [2] ANTONIOLI GE, 1993, NEW PERSPECTIVES CAR, P359
  • [3] ATRIAL STIMULATION BY MEANS OF FLOATING ELECTRODES - A MULTICENTER EXPERIENCE
    BONGIORNI, MG
    BEDENDI, N
    BACCA, F
    BINAGHI, G
    BONGIORNI, MG
    BOSSI, M
    CALCATERRA, V
    DIBIASE, M
    FERRI, F
    IACONO, M
    ORLANDI, M
    PASCOTTO, P
    ROTIROTI, D
    SANDRI, R
    VERGASSOLA, R
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1977 - 1981
  • [4] BONGIORNI MG, 1990, NEW TRENDS ARRHYTHMI, V4, P107
  • [5] EUROPEAN MULTICENTER PROSPECTIVE FOLLOW-UP-STUDY OF 1,002 IMPLANTS OF A SINGLE LEAD VDD PACING SYSTEM
    CRICK, JCP
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1742 - 1744
  • [6] A MULTICENTER EVALUATION OF A SINGLE-PASS LEAD VDD PACING SYSTEM
    CURZIO, G
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (03): : 434 - 442
  • [7] SINUS NODE DYSFUNCTION
    DHINGRA, RC
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (05): : 1062 - 1069
  • [8] HARTUNG WM, 1994, CIRCULATION, V90, P69
  • [9] HARTUNG WM, 1995, CIRCULATION, V92, P533
  • [10] HARTUNG WM, 1996, PACING CLIN ELECTROP, V19, P601