Verification of IMRT dose distributions using a water beam imaging system

被引:0
作者
Li, JS [1 ]
Boyer, AL [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
IMRT; quality assurance (QA); dosimetry Monte Carlo; water beam imaging system (WBIS);
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation image was captured by the camera. The pixel value in this image indicated the dose value in the scintillation screen. Images of radiation fields of known spatial distributions were used to calibrate the device. The verification was performed by comparing the image acquired from the measurement with a dose distribution from the IMRT plan. Because of light scattering in the scintillator screen, the image was blurred. A correction for this was developed by recognizing that the blur function could be fitted to a multiple Gaussian. The blur function was computed using the measured image of a 10 cm x 10 cm x-ray beam and the result of the dose distribution calculated using the Monte Carlo method. Based on the blur function derived using this method, an iterative reconstruction algorithm was applied to recover the dose distribution for an IMRT plan from the measured WBIS image. The reconstructed dose distribution was compared with Monte Carlo simulation result. Reasonable agreement was obtained from the comparison. The proposed approach makes it possible to carry out a real-time comparison of the dose distribution in a transverse plane between the measurement and the reference when we do an IMRT dose verification. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2466 / 2474
页数:9
相关论文
共 13 条
[1]   REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS [J].
BORTFELD, T ;
BOYER, AL ;
SCHLEGEL, W ;
KAHLER, DL ;
WALDRON, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :899-908
[2]  
BOYER AL, 1993, P 3D RAD TREATM PLAN
[3]   Verification of segmented beam delivery using a commercial electronic portal imaging device [J].
Curtin-Savard, AJ ;
Podgorsak, EB .
MEDICAL PHYSICS, 1999, 26 (05) :737-742
[4]   Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters [J].
Ibbott, GS ;
Maryanski, MJ ;
Eastman, P ;
Holcomb, SD ;
Zhang, YS ;
Avison, RG ;
Sanders, M ;
Gore, JC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05) :1097-1103
[5]   Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning [J].
Li, JS ;
Pawlicki, T ;
Deng, J ;
Jiang, SB ;
Mok, E ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :2969-2985
[6]   Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system [J].
Ma, CM ;
Pawlicki, T ;
Jiang, SB ;
Li, JS ;
Deng, J ;
Mok, E ;
Kapur, A ;
Xing, L ;
Ma, L ;
Boyer, AL .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2483-2495
[7]  
Ma CM, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P123
[8]  
MA CM, 1999, MED PHYS, V26, P1148
[9]   Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system [J].
Ma, LJ ;
Geis, PB ;
Boyer, AL .
MEDICAL PHYSICS, 1997, 24 (08) :1213-1220
[10]  
Nelson R, 1985, SLAC265