Liquid chromatographic mass spectrometric (LC/MS/MS) determination of plasma hydroxocobalamin and cyanocobalamin concentrations after hydroxocobalamin antidote treatment for cyanide poisoning

被引:25
|
作者
Schwertner, Harvey A. [1 ]
Valtier, Sandra [1 ]
Bebarta, Vikhyat S. [1 ]
机构
[1] Wilford Hall Ambulatory Surg Ctr, Div Clin Res, Lackland AFB, TX 78236 USA
关键词
Hydroxocobalamin; Cyanocobalamin; LC/MS/MS analysis; Cyanide poisoning antidote; Pharmacokinetics; Porcine models; SODIUM THIOSULFATE; PHARMACOKINETICS; COBALAMINS; TOXICITY; EFFICACY;
D O I
10.1016/j.jchromb.2012.07.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cyanide poisoning occurs in individuals after fire smoke inhalation and after oral ingestion of cyanide. Hydroxocobalamin (HOCbl), a hydroxylated form of vitamin B-12, is often used as an antidote to treat cyanide toxicity. It has a high affinity for cyanide and rapidly removes cyanide from tissue by forming cyanocobalamin (CNCbl). Little information is available on the pharmacokinetics of HOCbl and CNCbl largely because of the lack of analytical methods for analyzing HOCbl and CNCbl. In this study, we developed a new liquid chromatographic mass spectrometric (LC/MS/MS) method for the quantitative analysis of plasma HOCbl and CNCbl in the porcine (Sus scrofa) model. The method uses on-column extraction, reversed phase gradient chromatography, and multiple reaction monitoring (MRM) for quantitation. MRM transitions monitored were 664.7 -> 147.3 and 664.7 -> 359.2 for HOCbl and 678.8 -> 147.3, 678.8 -> 359.1 678.8 -> 457.1 for CNCbl. The limit of detection (LOD) and the lower limit of quantitation (LLOQ) were 1.0 and 1.0 mu mole/L, respectively, for plasma HOCbl and 0.1 and 0.5 mu mole/L for plasma CNCbl. The within-day and between-day CVs were 4.3 and 6.4% for plasma HOCbl at 500.0 mu mole/L and 5.5 and 5.7% for CNCbl at 100.0 mu mole/L (n = 6). The plasma HOCbl and CNCbl calibrations curves were linear from 100.0 to 2000.0 and 50.0 to 500.0 mu mole/L, respectively. Based on 6 separate calibration curves the average linear regression coefficient (R-2) for both HOCbl and CNCbl was 0.992. The LC/M/MS method was found to be accurate and precise and has been validated by determining the plasma HOCbl and CNCbl concentrations in 11 pigs that were treated with HOCbl for cyanide poisoning. Published by Elsevier B.V.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination of cantharidin in biological specimens and application to postmortem interval estimation in cantharidin poisoning
    Youyou Zhang
    Liang Liu
    Liang Ren
    Scientific Reports, 10
  • [42] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination of cantharidin in biological specimens and application to postmortem interval estimation in cantharidin poisoning
    Zhang, Youyou
    Liu, Liang
    Ren, Liang
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [43] Online capillary solid phase extraction and liquid chromatographic separation with quantitative tandem mass spectrometric detection (SPE-LC-MS/MS) of ximelagatran and its metabolites in a complex matrix
    Arvidsson, Bjorn
    Allard, Erik
    Sjogren, Erik
    Lennernas, Hans
    Sjoberg, Per Johan Ragnar
    Bergquist, Jonas
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 291 - 297
  • [44] A liquid chromatographic-mass spectrometric (LC-MS) method for the analysis of the bis-pyridinium oxime ICD-585 in plasma: Application in a guinea pig model
    Capacio, B. R.
    Dusick, B.
    Smith, J. R.
    McDonough, J. H.
    Shih, T-M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (17-18): : 1420 - 1425
  • [45] Determination of pazopanib (GW-786034) in mouse plasma and brain tissue by liquid chromatography-tandem mass spectrometry (LC/MS-MS)
    Minocha, Mukul
    Khurana, Varun
    Mitra, Ashim K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 901 : 85 - 92
  • [46] Determination of plasma Levetiracetam level by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS-MS) and its application in pharmacokinetics studies in neonates
    Jenjirattithigarn, Nuttawut
    Worachat, Nattha
    Horsuwan, Suchawadee
    Puangpetch, Apichaya
    Prempunpong, Chatchay
    Khongkhatithum, Chaiyos
    Thampratankul, Lunliya
    Prommas, Santirat
    Visudtibhan, Anannit
    Sukasem, Chonlaphat
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1085 : 13 - 20
  • [47] Liquid chromatography-electrospray mass spectrometry (LC-MS) method for determination of esmolol concentration in human plasma
    Zuppa, AF
    Shi, H
    Adamson, PC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02): : 293 - 301
  • [48] Simultaneous determination of Avanafil and Dapoxetine in human plasma using liquid chromatography/tandem mass spectrometry (LC-MS/MS) based on a protein precipitation technique
    Abou-Omar, Mona N.
    Annadi, Abdelaziz M.
    El Zahar, Noha M.
    Youssef, Ahmed O.
    Amin, Mohammed A.
    Attia, Mohamed S.
    Mohamed, Ekram H.
    RSC ADVANCES, 2021, 11 (47) : 29797 - 29806
  • [49] Determination of dehydroandrographolide succinate in human plasma by liquid chromatography tandem mass spectrometry (LC-MS/MS): Method development, validation and clinical pharmacokinetic study
    Li, Shuijun
    Yang, Ding
    Zhang, Mengqi
    Zhou, Juzhen
    Li, Rui
    Lu, Chuan
    Liu, Yun
    Liu, Yanmei
    Wang, Yiping
    Yu, Chen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24): : 2274 - 2279
  • [50] Experimental research for determination of bisoprolol fumarate in human plasma samples using liquid chromatography- tandem mass spectrometry (LC-MS/MS) technique
    Peste, Gabriela
    Oniscu, Corneliu
    Vlase, Aurel
    ROMANIAN BIOTECHNOLOGICAL LETTERS, 2010, 15 (02): : 5140 - 5145