Sliding-Mode-Based Direct Power Control of Grid-Connected Wind-Turbine-Driven Doubly Fed Induction Generators Under Unbalanced Grid Voltage Conditions

被引:156
作者
Shang, Lei [1 ,2 ]
Hu, Jiabing [3 ]
机构
[1] Nari Relays Elect Co Ltd, Nanjing 211100, Jiangsu, Peoples R China
[2] Huazhong Univ Sci & Technol, Coll Elect & Elect Engn, Wuhan 430074, Peoples R China
[3] State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Direct power control (DPC); doubly fed induction generator (DFIG); power compensation; sliding mode control (SMC); unbalanced grid voltage; wind turbine; DIRECT TORQUE CONTROL; SWITCHING FREQUENCY; DFIG; CONVERTERS; MACHINE; SYSTEMS; RIPPLE;
D O I
10.1109/TEC.2011.2180389
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes an improved direct power control (DPC) strategy of grid-connected wind-turbine-driven doubly fed induction generators (DFIGs) when the grid voltage is unbalanced. The DPC scheme is based on the sliding mode control (SMC) approach, which directly regulates the instantaneous active and reactive powers in the stator stationary reference frame without the requirement of either synchronous coordinate transformation or phase angle tracking of grid voltage. The behavior of DFIGs by the conventional SMC-DPC, which takes no negative-sequence voltage into consideration, is analyzed under unbalanced grid voltage conditions. A novel power compensation method is proposed for the SMC-based DPC during network unbalance to achieve three selective control targets, i.e., obtaining sinusoidal and symmetrical stator current, removing stator interchanging reactive power ripples and canceling stator output active power oscillations, respectively. The active and reactive power compensation components are calculated via a simple method and the proposed three control targets can be achieved, respectively, without the need of extracting negative-sequence stator current components. Experimental results on a 2kW DFIG prototype are presented to verify the correctness and validity of the proposed control strategy and power compensation method.
引用
收藏
页码:362 / 373
页数:12
相关论文
共 50 条
  • [31] Control strategy for doubly-fed wind power system under unbalanced and harmonic distorted grid voltage conditions
    Yao, Jun
    Chen, Zhiqian
    Li, Qing
    Yu, Mengting
    Zhou, Te
    Zhao, Lei
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2014, 38 (18): : 6 - 12
  • [32] Improvement of dynamic performance of doubly fed induction generator-based wind turbine power system under an unbalanced grid voltage condition
    Mwasilu, F.
    Justo, J. J.
    Ro, K. -S.
    Jung, J. -W.
    IET RENEWABLE POWER GENERATION, 2012, 6 (06) : 424 - 434
  • [33] High-order sliding mode control method for doubly-fed wind power generator under unbalanced grid voltage
    Zhang H.-Y.
    Wang J.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2019, 23 (04): : 37 - 48
  • [34] Rotor power control in doubly fed induction generator wind turbine under grid faults
    Hachicha, Fatma
    Krichen, Lotfi
    ENERGY, 2012, 44 (01) : 853 - 861
  • [35] Current-based direct power control of a DFIG under unbalanced grid voltage
    Farshadnia, Mohammad
    Taher, Seyed Abbas
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 571 - 582
  • [36] Direct Active and Reactive Power Regulation of Grid-Connected DC/AC Converters Using Sliding Mode Control Approach
    Hu, Jiabing
    Shang, Lei
    He, Yikang
    Zhu, Z. Q.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) : 210 - 222
  • [37] High-order sliding mode control of DFIG under unbalanced grid voltage conditions
    Xiong, Linyun
    Li, Penghan
    Wang, Jie
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 117 (117)
  • [38] Negative Sequence Control Strategy for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Conditions
    Park, Yonggyun
    Han, Daesu
    Suh, Yongsug
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1118 - 1124
  • [39] A New Robust Decoupled Control of the Stator Active and Reactive Currents for Grid-Connected Doubly-Fed Induction Generators
    Ataji, Ahmad Bashar
    Miura, Yushi
    Ise, Toshifumi
    Tanaka, Hiroki
    ENERGIES, 2016, 9 (03):
  • [40] A Genetic Algorithm-Based Low Voltage Ride-Through Control Strategy for Grid Connected Doubly Fed Induction Wind Generators
    Vrionis, Theodoros D.
    Koutiva, Xanthi I.
    Vovos, Nicholas. A.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (03) : 1325 - 1334