Plasma limiter for protecting against high power microwave

被引:0
作者
Yang, Geng [1 ]
Tan, Ji-chun [1 ]
Shem, Ding-yi [1 ]
Yang, Yu-chuan [1 ]
机构
[1] Natl Univ Def Technol, Coll Sci, Tech Phys Res Inst, Changsha, Hunan, Peoples R China
来源
JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH | 2008年 / 67卷 / 09期
关键词
electronic systems; high power microwave; plasma limiter;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Breakdown parameters of plasma limiter are calculated to find new measure to protect electronic systems against high Power microwave (HPM). Limiter filled with Xe of 1 torr can be charged by incident HPM in approximate 14 ns, providing protection to electronic systems.