Analysis of inline-filter blockage with trastuzumab formulation using scanning-electron microscopy

被引:1
|
作者
Ogawa, Chiaki [1 ,3 ]
Inoue, Motoki [2 ]
Yatabe, Megumi [1 ]
Nagayama, Yoshiyuki [1 ]
Gomi, Hiroko [1 ]
Nakadate, Kazuhiko [2 ]
Adachi, Shigeru [2 ]
Yachi, Yutaka [1 ]
Itoh, Tomoo [3 ]
机构
[1] Tokyo Med Ctr, Dept Pharm, Natl Hosp Org, Meguro Ku, 2-5-1 Higashigaoka, Tokyo 1528902, Japan
[2] Meiji Pharmaceut Univ, 2-522-1 Noshio, Kiyose, Tokyo 2048588, Japan
[3] Kitasato Univ, Lab Pharmaceut, Sch Pharm, Minato Ku, 5-9-1 Shirokane, Tokyo 1088641, Japan
关键词
Inline-filter; Blockage; Trastuzumab; Scanning-electron microscopy; CHEMOTHERAPY PLUS RITUXIMAB; PHARMACOKINETICS; CHOP;
D O I
10.1016/j.biopha.2019.108711
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The instability of pharmaceutical monoclonal antibodies are affected by physical stimuli including, temperature, denaturant, surfactant, stirring, solid phase adsorption, oxidation, and ultraviolet rays. Clinically, we frequently experience precipitation during preparation of several pharmaceutical monoclonal antibodies for cancer. Although it is possible to remove precipitates in the injection solution during the preparation procedure, potential filter blockade during administration remains a problem with adverse effects on the quality of life of patients. Therefore we sought to investigate factors contributing to this phenomenon. To closely observed the mechanisms involved in blockade of filters during trastuzumab preparation, we prepared samples under the same conditions used in clinical practice and observed them comprehensively. The precipitates that caused filter blockade were observed when the samples were vigorously shaken and left for several hours after dissolving. The precipitates were identified as proteins. The vigorous shaking caused contact between the protein and air, which induced protein precipitation caused by the surfactants derived from the foam formation. We discovered that the external stimulation may cause the instability of monoclonal antibody preparations and, so, it is important for procedures to be as rapid to avoid precipitate formation as much as possible.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] MORPHOLOGICAL ANALYSIS AND LOCALIZATION OF BACTERIAL SPECIES THAT COHABIT WITH Arthrospira sp USING SCANNING ELECTRON MICROSCOPY
    Sena D'Anna, L.
    De Sisto, A.
    Duque, Z.
    Rojas, D.
    Naranjo, L.
    ACTA MICROSCOPICA, 2013, 22 (02): : 195 - 204
  • [32] Morphometric analysis of the corneal endothelium of Yacare caiman (Caiman yacare) using scanning electron microscopy
    Pigatto, JAT
    Andrade, MC
    Laus, JL
    Santos, JM
    Brooks, DE
    Guedes, PM
    Barros, PSM
    VETERINARY OPHTHALMOLOGY, 2004, 7 (03) : 205 - 208
  • [33] A scanning electron microscopy analysis of a spontaneous hemodialysis catheter fracture
    Weijmer, MC
    Kars, SM
    ter Wee, PM
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (04) : 858 - 861
  • [34] Local depth monitoring using scanning electron microscopy and its verification using atomic force microscopy
    Park, Inseok
    Ahn, JaeHyung
    Lee, Donghyun
    Kim, Souk
    Rim, Minho
    Sohn, Younghoon
    METROLOGY, INSPECTION, AND PROCESS CONTROL XXXVII, 2023, 12496
  • [35] Correlative analysis of immunoreactivity in confocal laser-scanning microscopy and scanning electron microscopy with focused ion beam milling
    Sonomura, Takahiro
    Furuta, Takahiro
    Nakatani, Ikuko
    Yamamoto, Yo
    Unzai, Tomo
    Matsuda, Wakoto
    Iwai, Haruki
    Yamanaka, Atsushi
    Uemura, Masanori
    Kaneko, Takeshi
    FRONTIERS IN NEURAL CIRCUITS, 2013, 7
  • [36] Study of aging products of transformer oil using scanning electron microscopy
    Lyadov, N. M.
    Turanova, O. A.
    Kozlov, V. K.
    Turanov, A. N.
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 2013, 49 (04) : 362 - 367
  • [38] Double staining method for array tomography using scanning electron microscopy
    Kim E.
    Lee J.
    Noh S.
    Kwon O.
    Mun J.Y.
    Applied Microscopy, 2020, 50 (01)
  • [39] Study of aging products of transformer oil using scanning electron microscopy
    N. M. Lyadov
    O. A. Turanova
    V. K. Kozlov
    A. N. Turanov
    Chemistry and Technology of Fuels and Oils, 2013, 49 : 362 - 367
  • [40] Location of fines in mechanical pulp handsheets using scanning electron microscopy
    DeSilveira, G
    Zhang, X
    Berry, R
    Wood, JR
    JOURNAL OF PULP AND PAPER SCIENCE, 1996, 22 (09): : J315 - J320