The Change in Retentive Values of Locator Attachments and Hader Clips over Time

被引:87
作者
Evtimovska, Elizabeta
Masri, Radi [1 ]
Driscoll, Carl F. [2 ]
Romberg, Elaine [3 ]
机构
[1] Univ Maryland, Baltimore Coll Dent Surg, Dept Endodont Prosthodont & Operat Dent, Baltimore, MD 21201 USA
[2] Univ Maryland, Baltimore Coll Dent Surg, Postgrad Prosthodont Program, Baltimore, MD 21201 USA
[3] Univ Maryland, Baltimore Coll Dent Surg, Dept Hlth Promot & Policy, Baltimore, MD 21201 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2009年 / 18卷 / 06期
关键词
Implant-retained overdenture; attachments; retention;
D O I
10.1111/j.1532-849X.2009.00474.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to examine early changes in retentive values of implant overdenture attachments during multiple pulls. Materials and Methods: Two implant attachment systems (Hader bar and clip, Locator system) were used in this study. The experimental groups were divided into yellow Hader clips, white Locator attachments, and green Locator attachments. Each group consisted of 21 matrix attachments. The attachments were placed into a custom-made acrylic resin block seated passively on another acrylic block containing a Hader bar or two Locator abutments with different angulations. Each attachment was subjected to 20 consecutive pulls using a universal testing machine. The peak load-to-dislodgement of the attachments after each pull was documented, and the percent reduction of the peak load-to-dislodgement was calculated. One-way ANOVA and Tukey's honestly significant difference test were used for data analyses. A p <= 0.05 was considered significant. Results: There was a significant difference in the percent reduction in peak load-to-dislodgement between the attachments after the first pull (p = 0.005) and after the final pull (p = 0.0001). The yellow Hader clips exhibited the least percent reduction in peak load-to-dislodgement (6.50 +/- 3.59%) after the first pull, followed by the white Locator attachments (8.60 +/- 4.42%); the green Locator attachments exhibited the greatest reduction (11.05 +/- 4.94%). Conclusion: The results of this in vitro study demonstrate that retentive values of the Locator attachments are reduced significantly after multiple pulls. Although this reduction might not be noticeable to the patient, it is recommended that the clinician place and remove the overdenture multiple times before delivery.
引用
收藏
页码:479 / 483
页数:5
相关论文
共 13 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   The effect of simulated function on the retention of bar-clip retained removable prostheses [J].
Breeding, LC ;
Dixon, DL ;
Schmitt, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (05) :570-573
[3]  
Chung Kwok-Hung, 2004, J Prosthodont, V13, P221
[4]   ALVEOLAR BONE LOSS IN OVERDENTURES - 5-YEAR STUDY [J].
CRUM, RJ ;
ROONEY, GE .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (06) :610-613
[5]  
Feine J S, 2002, Int J Prosthodont, V15, P413
[6]  
Jemt T, 1996, Int J Oral Maxillofac Implants, V11, P291
[7]   BONE-RESORPTION AROUND FIXTURES IN EDENTULOUS PATIENTS TREATED WITH MANDIBULAR FIXED TISSUE-INTEGRATED PROSTHESES [J].
LINDQUIST, LW ;
ROCKLER, B ;
CARLSSON, GE .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (01) :59-63
[8]   A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy - Part I: peri-implant outcome [J].
Naert, I ;
Gizani, S ;
Vuylsteke, M ;
van Steenberghe, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (03) :170-177
[9]   PERIODONTAL ASPECTS OF OSSEOINTEGRATED FIXTURES SUPPORTING A PARTIAL BRIDGE - AN UP TO 6-YEARS RETROSPECTIVE STUDY [J].
QUIRYNEN, M ;
NAERT, I ;
VANSTEENBERGHE, D ;
DEKEYSER, C ;
CALLENS, A .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (02) :118-126
[10]  
SADOWSKY SJ, 2000, J PROSTHET DENT, V15, P383