Analysis of Key Interference Sources Affecting CCD Measurement Accuracy

被引:0
|
作者
Chen Donggen [1 ]
Xu Jiangtao [2 ]
Liu Hongwei [3 ]
Cui Kaibo [1 ]
机构
[1] Mech Engn Coll, Shijiazhuang, Hebei, Peoples R China
[2] Unit 63981, Wuhan, Hubei, Peoples R China
[3] Unit 63983, Wuxi, Jiangsu, Peoples R China
来源
2016 IEEE INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC) | 2016年
关键词
linear CCD; accuracy; interference sources; stray light;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In actual field test environments, unstable CCD measuring spot center position, the total appears slight shaking, so that measurements and calculated spot position and displacement there is a big error. This paper studies the field environments offline Array CCD measurement technology characteristics, analyzes the key sources of interference affecting the measurement accuracy linear CCD, combined with the test environment design solutions.
引用
收藏
页码:1018 / 1021
页数:4
相关论文
共 36 条
  • [31] Analysis of rotational velocity measurement accuracy and signal-to-noise ratio of balanced detection based on vortex beam (Invited)
    Sha Q.
    Wang W.
    Liu T.
    Liu Z.
    Qiu S.
    Ren Y.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (09):
  • [32] Analysis of factors affecting the accuracy of low-dose insulin dosage using syringes and vials: a cross-sectional study in a Japanese regional hospital
    Kondo, Manabu
    Saji, Rika
    Yamada, Yuka
    Hayashi, Mari
    Shirai, Tomoko
    DIABETOLOGY INTERNATIONAL, 2024, 15 (03) : 544 - 549
  • [33] A novel approach to multi-path ultrasonic transit time flow meter based on measurement model analysis to improve accuracy
    Ton, V.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2023, 91
  • [34] Accuracy of Spleen Stiffness Measurement in Detection of Esophageal Varices in Patients With Chronic Liver Disease: Systematic Review and Meta-analysis
    Singh, Siddharth
    Eaton, John E.
    Murad, Mohammad H.
    Tanaka, Hironori
    Iijima, Hiroko
    Talwalkar, Jayant A.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2014, 12 (06) : 935 - +
  • [35] Analysis of Measurement System Accuracy Based on 2D Laser Triangulation Scanner When Measuring Soiled Pipe Thread Pitch and Height
    Lavrinov, D. S.
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, ICIE 2019, VOL II, 2020, : 521 - 529
  • [36] Analysis of a Unique Postmarket Surveillance Dataset That a Glucose Test-Strip Demonstrates no Evidence of Interference and Robust Clinical Accuracy Irrespective of the Prescription Medication Status of a Large Cohort of Patients With Diabetes
    Grady, Mike
    Cameron, Hilary
    Phillips, Stuart
    Smith, Gillian
    Setford, Steven
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (01): : 82 - 90