Concentration of dipotassium ethylenediaminetetraacetic acid but not lithium heparin affects total protein determination in equine synovial fluid

被引:1
作者
Rihuete, Pablo Jimenez [1 ]
Villarino, Nicolas [2 ]
Pelisiak, Alicja [3 ]
Rubio-Martinez, Luis M. [1 ,4 ]
机构
[1] Univ Liverpool, Dept Equine Clin Sci, Inst Vet Sci, Liverpool, Merseyside, England
[2] Washington State Univ, Program Individualized Med, Pullman, WA 99164 USA
[3] RSPCA Stapeley Grange, Wildlife Ctr, Nantwich, England
[4] Sussex Equine Hosp, Ashington RH20 3BB, England
关键词
TOTAL SERUM-PROTEINS; PASSIVE TRANSFER; ANTICOAGULANTS; REFRACTOMETER; CANINE; EDTA;
D O I
10.1136/vr.105567
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Refractometric determination of total protein (TP) in synovial fluid (SF) is commonly used for diagnosis and monitoring of synovial sepsis in horses. Previous studies have shown that elevated concentrations of certain anticoagulants may overestimate refractometric determination of TP concentration. Objectives The aim of the study was to evaluate the effect of different concentrations of dipotassium EDTA (K(2)EDTA) and lithium heparin (LH) on TP determination by using a hand-held refractometer in equine synovial fluid. Study design Cross-section observational study. Methods Thirty samples of synovial fluid obtained from 22 horses with different synovial conditions were collected. Synovial fluid samples were separated into different aliquots and placed in commercially available collection tubes containing K(2)EDTA or LH at four different concentrations (1.76, 3.52, 7.04 and 17.6 mg/ml for K(2)EDTA; 16, 32, 64 and 160 IU/ml for LH). Refractometric TP determination was performed on untreated and K(2)EDTA and LH aliquots with a hand-held refractometer and by spectophotometric Biuret method as the gold standard. Results Refractometric TP determination was overestimated in SF samples containing 10 times the recommended K2EDTA concentrations. Lower concentrations of K(2)EDTA and LH concentrations did not affect refractometric TP determinations. Main limitations Limited number of samples mostly obtained from large synovial structures. Conclusion To avoid incorrect TP determination, the use of LH containing collection tubes may be an appropriate alternative when the SF volume available is not enough to fill the K(2)EDTA collection tube.
引用
收藏
页数:5
相关论文
共 29 条
[1]  
Ahmed Imtiaz, 2014, Journal of Ecophysiology and Occupational Health, V14, P117, DOI 10.15512/joeoh/2014/v14i3&4/59996
[2]   Refractometry as an alternative to the biuret method for measuring total serum proteins in Podocnemis expansa (Podocnemididae) and Phrynops geoffroanus (Chelidae) [J].
Bezerra Pessoa, Lourdes Marina ;
da Mota Lima, Maira Goncalves ;
Carneiro, Filipe Tavares ;
Zanani, Nathalia Salgado ;
Scalon, Marcela Correa ;
Silva, Thamiris Figueiredo ;
Lima, Mariana Accioly ;
Abrahim, Maia Araujo ;
Paludo, Giane Regina .
ACTA AMAZONICA, 2017, 47 (01) :83-85
[3]  
Carlson G P, 1977, Vet Clin Pathol, V6, P18, DOI 10.1111/j.1939-165X.1977.tb00771.x
[4]  
CHIARAVIGLIO EC, 1963, AM J CLIN PATHOL, V39, P42
[5]  
Denton J., 2012, Diagnostic Histopathol, V18, P159
[6]   DETERMINATION OF TOTAL SERUM PROTEIN BY MEANS OF REFRACTIVE INDEX OF SERUM [J].
DRICKMAN, A ;
MCKEON, FA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1962, 38 (04) :392-&
[7]  
DUBIN S, 1978, LAB ANIM SCI, V28, P541
[8]   The influence of anticoagulants on the measurement of total protein concentration in equine peritoneal fluid [J].
Estepa, JC ;
Lopez, I ;
Mayer-Valor, R ;
Rodriguez, M ;
Aguilera-Tejero, E .
RESEARCH IN VETERINARY SCIENCE, 2006, 80 (01) :5-10
[9]   EVALUATION OF 5 COMMONLY USED ANTICOAGULANTS, IN RELATION TO ACCURACY OF HEMATOLOGICAL TESTS FOR BOVINE, OVINE, EQUINE AND CANINE BLOOD [J].
FALCONER, GJ ;
CHAPMAN, PN .
NEW ZEALAND VETERINARY JOURNAL, 1977, 25 (04) :86-89
[10]   The usefulness and limitations of hand-held refractometers in veterinary laboratory medicine: An historical and technical review [J].
George, JW .
VETERINARY CLINICAL PATHOLOGY, 2001, 30 (04) :201-210