One of the greatest challenges in the development of very sensitive radiation detectors is the fabrication of a large detector array. Within this context we have started the development of Kinetic Inductance Detectors. The heart of each detector consists of a high-Q superconducting quarter wavelength microwave resonator. As a result, it is easy to multiplex the readout by frequency division multiplexing. We describe our initial experiments with these resonators, made oil 20 x 4 mm high-purity Si chips using 100 nm Nb films. We measure the Q factors of several resonators using a vector network analyzer and find Q factors up to 90.000, limited by the intrinsic quality of the Nb resonator. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:567 / 569
页数:3
相关论文
共 5 条
[1]   A broadband superconducting detector suitable for use in large arrays [J].
Day, PK ;
LeDuc, HG ;
Mazin, BA ;
Vayonakis, A ;
Zmuidzinas, J .
NATURE, 2003, 425 (6960) :817-821
[2]  
Mazin B. A., 2004, THESIS CALTECH
[3]   Calculation of the characteristics of coplanar resonators for kinetic inductance detectors [J].
Porch, A ;
Mauskopf, P ;
Doyle, S ;
Dunscombe, C .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :552-555
[4]  
WADEFALK N, 2005, IN PRESS IEEE IMS 20
[5]  
2002, COMMUNITY PLAN FAR I