SURVEILLANCE OF DEVICE-ASSOCIATED INFECTION RATES AND MORTALITY IN 3 GREEK INTENSIVE CARE UNITS

被引:17
|
作者
Apostolopoulou, Eleni [1 ]
Raftopoulos, Vasilios [2 ]
Filntisis, Georgios [1 ]
Kithreotis, Prokopis [3 ]
Stefanidis, Evagelos [3 ]
Galanis, Petros
Veldekis, Dimitrios [3 ]
机构
[1] Univ Athens, Dept Nursing, Athens, Greece
[2] Cyprus Univ Technol, Dept Nursing, CY-2029 Nicosia, Cyprus
[3] SOTIRIA Gen Hosp, Intens Care Unit, Athens, Greece
关键词
BLOOD-STREAM INFECTIONS; VENTILATOR-ASSOCIATED PNEUMONIA; NETWORK NHSN REPORT; NOSOCOMIAL INFECTIONS; SAFETY NETWORK; ACINETOBACTER-BAUMANNII; HOSPITALS; RISK; RESISTANCE; PROGRAMS;
D O I
10.4037/ajcc2013324
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Several studies suggest that device-associated, health care-associated infections (DA-HAIs) affect the quality of care in intensive care units, increasing patients' morbidity and mortality and the costs of patient care. Objectives To assess the DA-HAIs rates, microbiological profile, antimicrobial resistance, and crude excess mortality in 3 intensive care units in Athens, Greece. Methods A prospective cohort, active DA-HAI surveillance study was conducted in 3 Greek intensive care units from July 2009 to June 2010. The rates of mechanical ventilator-associated pneumonia (VAP), central catheter-associated bloodstream infection (CLABSI), and catheter-associated urinary tract infection (CAUTI) were calculated along with microbiological profile, antimicrobial resistance, and crude excess mortality. Results During 6004 days in intensive care, 152 of 294 patients acquired 205 DA-HAIs, an overall rate of 51.7% of patients or 34.1 DA-HAIs per 1000 days (95% CI, 29.3-38.6). The VAP rate was 20 (95% CI, 16.3-23.7) per 1000 ventilator-days, the CLABSI rate was 11.8 (95% CI: 9.2-14.8) per 1000 catheter-days, and the CAUTI rate was 4.2 (95% CI, 2.5-5.9) per 1000 catheter-days. The most frequently isolated pathogen was Acinetobacter baumannii among patients with CLABSI (37.8%) and Candida species among patients with CAUTI (66.7%). Excess mortality was 20.3% for VAP and CLABSI and 32.2% for carbapenem-resistant A baumannii CLABSI. Conclusion High rates of DA-HAIs, device utilization, and anti microbial resistance emphasize the need for antimicrobial stewardship, the establishment of an active surveillance program of DA-HAIs, and the implementation of evidence-based preventive strategies.
引用
收藏
页码:E12 / E20
页数:9
相关论文
共 50 条
  • [1] Device-associated nosocomial infection rates in intensive care units in Greece
    Dima, Sofia
    Kritsotakis, Evangelos I.
    Roumbelaki, Maria
    Metalidis, Simeon
    Karabinis, Andreas
    Maguina, Nina
    Klouva, Fyllis
    Levidiotou, Stamatina
    Zakynthinos, Epaminondas
    Kioumis, John
    Gikas, Achilleas
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2007, 28 (05): : 602 - 605
  • [2] Device-associated nosocomial infection rates in intensive care units of Argentina
    Rosenthal, VD
    Guzmán, S
    Crnich, C
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2004, 25 (03): : 251 - 255
  • [3] Surveillance of Device-Associated Infections in Intensive Care Units in South Brazil
    Michelon Toledo, Paula Virginia
    Costa Oliveira, Juliane Cristina
    Luhm, Karin Regina
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2012, 33 (03): : 309 - 311
  • [4] Surveillance of device-associated infections in intensive care units of a tertiary care hospital
    Rizwan, M.
    Ikram, A.
    Zaman, G.
    Satti, L.
    Ahmed, P.
    JOURNAL OF HOSPITAL INFECTION, 2017, 95 (01) : 101 - 102
  • [5] Device-associated infection rates and mortality in intensive care units of Peruvian hospitals: findings of the International Nosocomial Infection Control Consortium
    Cuellar, Luis E.
    Fernandez-Maldonado, Eduardo
    Rosenthal, Victor D.
    Castaneda-Sabogal, Alex
    Rosales, Rosa
    Mayorga-Espichan, Manuel J.
    Camacho-Cosavalente, Luis A.
    Castillo-Bravo, Luis
    REVISTA PANAMERICANA DE SALUD PUBLICA-PAN AMERICAN JOURNAL OF PUBLIC HEALTH, 2008, 24 (01): : 16 - 24
  • [6] Device-associated infection and mortality in a Tunisian intensive care unit
    N Bouafia
    M Mahjoub
    I Chouchéne
    A Bencheikh
    O Ezzi
    S Bouchoucha
    M Njah
    Antimicrobial Resistance and Infection Control, 4 (Suppl 1)
  • [7] Device-associated infection rates and bacterial resistance in the intensive care units of a Turkish referral hospital
    Tutuncu, Emin E.
    Gurbuz, Yunus
    Sencan, Irfan
    Ozturk, Baris
    Senturk, Gonul C.
    Kilic, Aysegul U.
    SAUDI MEDICAL JOURNAL, 2011, 32 (05) : 489 - 494
  • [8] Device-associated nosocomial infection rates in intensive care units in four Mexican public hospitals
    Ramirez Barba, Ector Jaime
    Rosenthal, Victor Daniel
    Higuera, Francisco
    Sobreyra Oropeza, Martha
    Torres Hernandez, Hector
    Sanchez Lopez, Martha
    Lona, Elia Lara
    Duarte, Pablo
    Ruiz, Javier
    Rojas Hernandez, Raul
    Chavez, Amalia
    Perez Cerrato, Irma
    Ramirez Ramirez, Gloria Elena
    Safdar, Nasia
    AMERICAN JOURNAL OF INFECTION CONTROL, 2006, 34 (04) : 244 - 247
  • [9] Device-associated nosocomial infection rates in Turkish medical-surgical intensive care units
    Inan, Dilara
    Saba, Rabin
    Yalcin, Ata Nevzat
    Yilmaz, Murat
    Ongut, Gozde
    Ramazanoglu, Atilla
    Mamikoglu, Latife
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (04): : 343 - 348
  • [10] Device-associated infection rates in pediatric and neonatal intensive care units in El Salvador: Findings of the INICC
    Duenas, Lourdes
    Bran de Casares, Ana C.
    Rosenthal, Victor D.
    Jesus Machuca, Lilian