Time-Varying Coherence Function for Atrial Fibrillation Detection

被引:75
|
作者
Lee, Jinseok [1 ]
Nam, Yunyoung [2 ]
McManus, David D. [3 ,4 ]
Chon, Ki H. [2 ]
机构
[1] Wonkwang Univ, Dept Biomed Engn, Sch Med, Iksan, Jeonbuk, South Korea
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Ctr, Div Cardiol, Dept Med, Worcester, MA 01605 USA
[4] Univ Massachusetts, Med Ctr, Dept Quantitat Hlth Sci, Worcester, MA 01605 USA
关键词
Atrial fibrillation (AF); cardiac arrhythmia; ECG; parametric time-frequency spectra; Shannon entropy (SE); short physiological time series; time-varying coherence function; time-varying transfer function; SIGNAL-AVERAGED ELECTROCARDIOGRAM; RR INTERVALS; PREVALENCE; ALGORITHM; RISK; IDENTIFICATION; SYSTEM; RHYTHM; ECG;
D O I
10.1109/TBME.2013.2264721
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We introduce a novel method for the automatic detection of atrial fibrillation (AF) using time-varying coherence functions (TVCF). The TVCF is estimated by the multiplication of two time-varying transfer functions (TVTFs). The two TVTFs are obtained using two adjacent data segments with one data segment as the input signal and the other data segment as the output to produce the first TVTF; the second TVTF is produced by reversing the input and output signals. We found that the resultant TVCF between two adjacent normal sinus rhythm (NSR) segments shows high coherence values (near 1) throughout the entire frequency range. However, if either or both segments partially or fully contain AF, the resultant TVCF is significantly lower than 1. When TVCF was combined with Shannon entropy (SE), we obtained even more accurate AF detection rate of 97.9% for the MIT-BIH atrial fibrillation (AF) database (n = 23) with 128 beat segments. The detection algorithm was tested on four databases using 128 beat segments: the MIT-BIH AF database, the MIT-BIH NSR database (n = 18), the MIT-BIH Arrhythmia database (n = 48), and a clinical 24-h Holter AF database (n = 25). Using the receiver operating characteristic curves from the combination of TVCF and SE, we obtained a sensitivity of 98.2% and specificity of 97.7% for the MIT-BIH AF database. For the MIT-BIH NSR database, we found a specificity of 99.7%. For the MIT-BIH Arrhythmia database, the sensitivity and specificity were 91.1% and 89.7%, respectively. For the clinical database (24-h Holter data), the sensitivity and specificity were 92.3% and 93.6%, respectively. We also found that a short segment (12 beats) also provided accurate AF detection for all databases: sensitivity of 94.7% and specificity of 90.4% for the MIT-BIH AF, specificity of 94.4% for the MIT-BIH-NSR, the sensitivity of 92.4% and specificity of 84.1% for the MIT-BIH arrhythmia, and sensitivity of 93.9% and specificity of 84.4% for the clinical database. The advantage of using a short segment is more accurate AF burden calculation as the timing of transitions between NSR and AF are more accurately detected.
引用
收藏
页码:2783 / 2793
页数:11
相关论文
共 50 条
  • [41] CAPTURING DYNAMICS OF TIME-VARYING DATA VIA TOPOLOGY
    Xian, Lu
    Adams, Henry
    Topaz, Chad M.
    Ziegelmeier, Lori
    FOUNDATIONS OF DATA SCIENCE, 2022, 4 (01): : 1 - 36
  • [42] ECG Modeling for Simulation of Arrhythmias in Time-Varying Conditions
    Bachi, Lorenzo
    Halvaei, Hesam
    Perez, Cristina
    Martin-Yebra, Alba
    Petrenas, Andrius
    Solosenko, Andrius
    Johnson, Linda
    Marozas, Vaidotas
    Martinez, Juan Pablo
    Pueyo, Esther
    Stridh, Martin
    Laguna, Pablo
    Sornmo, Leif
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (12) : 3449 - 3460
  • [43] Business cycles synchronization in East Asian economy: Evidences from time-varying coherence study
    Allegret, Jean-Pierre
    Essaadi, Essahbi
    ECONOMIC MODELLING, 2011, 28 (1-2) : 351 - 365
  • [44] Atrial Fibrillation Detection on Electrocardiogram
    Mabrouki, Rebeh
    Khaddoumi, Balkine
    Sayadi, Mounir
    2016 2ND INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP), 2016, : 365 - 369
  • [45] Influence of atrial fibrillation detection time on outcome after endovascular thrombectomy
    Leker, R. R.
    Farraj, A.
    Filioglo, A.
    Sacagiu, T.
    Honig, A.
    Gomori, J. M.
    Cohen, J. E.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2020, 419
  • [46] A deep learning approach for real-time detection of atrial fibrillation
    Andersen, Rasmus S.
    Peimankar, Abdolrahman
    Puthusserypady, Sadasivan
    EXPERT SYSTEMS WITH APPLICATIONS, 2019, 115 : 465 - 473
  • [47] Atrial Fibrillation Detection and Atrial Fibrillation Burden Estimation via Wearables
    Zhu, Li
    Nathan, Viswam
    Kuang, Jilong
    Kim, Jacob
    Avram, Robert
    Olgin, Jeffrey
    Gao, Jun
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2063 - 2074
  • [48] Prolonged Cardiac Monitoring for Detection of Paroxysmal Atrial Fibrillation After Cerebral Ischemia
    Rabinstein, Alejandro A.
    STROKE, 2014, 45 (04) : 1208 - 1214
  • [49] Diagnostic Accuracy of a Novel Mobile Phone Application for the Detection and Monitoring of Atrial Fibrillation
    Rozen, Guy
    Vaid, Jeena
    Hosseini, Seyed Mohammadreza
    Kaadan, M. Ihsan
    Rafael, Allon
    Roka, Attila
    Poh, Yukkee C.
    Poh, Ming-Zher
    Heist, Edwin Kevin
    Ruskin, Jeremy Neil
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 121 (10) : 1187 - 1191
  • [50] A time-varying autoregressive model for groundwater depth prediction
    Guo, Tianli
    Song, Songbai
    Yan, Yating
    JOURNAL OF HYDROLOGY, 2022, 613