Time-Varying Coherence Function for Atrial Fibrillation Detection

被引:75
|
作者
Lee, Jinseok [1 ]
Nam, Yunyoung [2 ]
McManus, David D. [3 ,4 ]
Chon, Ki H. [2 ]
机构
[1] Wonkwang Univ, Dept Biomed Engn, Sch Med, Iksan, Jeonbuk, South Korea
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Ctr, Div Cardiol, Dept Med, Worcester, MA 01605 USA
[4] Univ Massachusetts, Med Ctr, Dept Quantitat Hlth Sci, Worcester, MA 01605 USA
关键词
Atrial fibrillation (AF); cardiac arrhythmia; ECG; parametric time-frequency spectra; Shannon entropy (SE); short physiological time series; time-varying coherence function; time-varying transfer function; SIGNAL-AVERAGED ELECTROCARDIOGRAM; RR INTERVALS; PREVALENCE; ALGORITHM; RISK; IDENTIFICATION; SYSTEM; RHYTHM; ECG;
D O I
10.1109/TBME.2013.2264721
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We introduce a novel method for the automatic detection of atrial fibrillation (AF) using time-varying coherence functions (TVCF). The TVCF is estimated by the multiplication of two time-varying transfer functions (TVTFs). The two TVTFs are obtained using two adjacent data segments with one data segment as the input signal and the other data segment as the output to produce the first TVTF; the second TVTF is produced by reversing the input and output signals. We found that the resultant TVCF between two adjacent normal sinus rhythm (NSR) segments shows high coherence values (near 1) throughout the entire frequency range. However, if either or both segments partially or fully contain AF, the resultant TVCF is significantly lower than 1. When TVCF was combined with Shannon entropy (SE), we obtained even more accurate AF detection rate of 97.9% for the MIT-BIH atrial fibrillation (AF) database (n = 23) with 128 beat segments. The detection algorithm was tested on four databases using 128 beat segments: the MIT-BIH AF database, the MIT-BIH NSR database (n = 18), the MIT-BIH Arrhythmia database (n = 48), and a clinical 24-h Holter AF database (n = 25). Using the receiver operating characteristic curves from the combination of TVCF and SE, we obtained a sensitivity of 98.2% and specificity of 97.7% for the MIT-BIH AF database. For the MIT-BIH NSR database, we found a specificity of 99.7%. For the MIT-BIH Arrhythmia database, the sensitivity and specificity were 91.1% and 89.7%, respectively. For the clinical database (24-h Holter data), the sensitivity and specificity were 92.3% and 93.6%, respectively. We also found that a short segment (12 beats) also provided accurate AF detection for all databases: sensitivity of 94.7% and specificity of 90.4% for the MIT-BIH AF, specificity of 94.4% for the MIT-BIH-NSR, the sensitivity of 92.4% and specificity of 84.1% for the MIT-BIH arrhythmia, and sensitivity of 93.9% and specificity of 84.4% for the clinical database. The advantage of using a short segment is more accurate AF burden calculation as the timing of transitions between NSR and AF are more accurately detected.
引用
收藏
页码:2783 / 2793
页数:11
相关论文
共 50 条
  • [1] Atrial Fibrillation Detection using Time-Varying Coherence Function and Shannon Entropy
    Lee, J.
    McManus, D.
    Chon, K.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4685 - 4688
  • [2] Automatic Real Time Detection of Atrial Fibrillation
    Dash, S.
    Chon, K. H.
    Lu, S.
    Raeder, E. A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (09) : 1701 - 1709
  • [3] Estimation of time-varying coherence function using time-varying transfer functions
    Zhao, H
    Lu, S
    Zou, R
    Ju, KW
    Chon, KH
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (11) : 1582 - 1594
  • [4] Estimation of Time-Varying Coherence Function Using Time-Varying Transfer Functions
    He Zhao
    Sheng Lu
    Rui Zou
    Kihwan Ju
    Ki H. Chon
    Annals of Biomedical Engineering, 2005, 33 : 1582 - 1594
  • [5] Automatic detection of atrial fibrillation using stationary wavelet transform and support vector machine
    Asgari, Shadnaz
    Mehrnia, Alireza
    Moussavi, Maryam
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 60 : 132 - 142
  • [6] Time-varying differences in stroke recurrence risk between types of atrial fibrillation based on screening methods and timing of detection
    Alvarado-Bolanos, Alonso
    Ayan, Diana
    Lodol, Facundo
    Khaw, Alexander V.
    Mai, Lauren M.
    Mandzia, Jennifer L.
    Mrkobrada, Marko
    Bres-Bullrich, Maria
    Fleming, Lorraine
    Lippert, Corbin
    Cecile, Meredith
    Bagur, Rodrigo
    Fridman, Sebastian
    Sposato, Luciano A.
    EUROPEAN STROKE JOURNAL, 2024,
  • [7] The Effects of Compression on the Detection of Atrial Fibrillation in ECG Signals
    Cervigon, Raquel
    McGinley, Brian
    Craven, Darren
    Glavin, Martin
    Jones, Edward
    APPLIED SCIENCES-BASEL, 2021, 11 (13):
  • [8] Detection, Classification, and Quantification of Nonlinear Distortions in Time-Varying Frequency Response Function Measurements
    Hallemans, Noel
    Pintelon, Rik
    Zhu, Xinhua
    Collet, Thomas
    Claessens, Raf
    Wouters, Benny
    Hubin, Annick
    Lataire, John
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [9] Automatic Real Time Detection of Atrial Fibrillation
    S. Dash
    K. H. Chon
    S. Lu
    E. A. Raeder
    Annals of Biomedical Engineering, 2009, 37 : 1701 - 1709
  • [10] Time-Varying EEG Correlations Improve Automated Neonatal Seizure Detection
    Tapani, Karoliina T.
    Vanhatalo, Sampsa
    Stevenson, Nathan J.
    INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2019, 29 (04)