The Effect of the CT Number for Each CT on Photon Dose Calculation
被引:0
作者:
Cho, Kwang Hwan
论文数: 0引用数: 0
h-index: 0
机构:
Soonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Kyonggi Univ, Dept Med Phys, Suwon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Cho, Kwang Hwan
[1
,2
]
Shin, Dongho
论文数: 0引用数: 0
h-index: 0
机构:
Natl Canc Ctr, Ctr Proton Therapy, Ilsan, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Shin, Dongho
[3
]
Cho, Sam Ju
论文数: 0引用数: 0
h-index: 0
机构:
Kyonggi Univ, Dept Med Phys, Suwon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Cho, Sam Ju
[2
]
Jang, Jisun
论文数: 0引用数: 0
h-index: 0
机构:
Kyonggi Univ, Dept Med Phys, Suwon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Jang, Jisun
[2
]
Lee, Sang Hoon
论文数: 0引用数: 0
h-index: 0
机构:
Kyonggi Univ, Dept Med Phys, Suwon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Lee, Sang Hoon
[2
]
Kim, Yong Ho
论文数: 0引用数: 0
h-index: 0
机构:
Soonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Kim, Yong Ho
[1
]
Choi, Doo Ho
论文数: 0引用数: 0
h-index: 0
机构:
Soonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Choi, Doo Ho
[1
]
Kim, Eun Seog
论文数: 0引用数: 0
h-index: 0
机构:
Soonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Kim, Eun Seog
[1
]
Kwon, Soo Il
论文数: 0引用数: 0
h-index: 0
机构:
Kyonggi Univ, Dept Med Phys, Suwon, South KoreaSoonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
Kwon, Soo Il
[2
]
机构:
[1] Soonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
[2] Kyonggi Univ, Dept Med Phys, Suwon, South Korea
[3] Natl Canc Ctr, Ctr Proton Therapy, Ilsan, South Korea
来源:
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6
|
2007年
/
14卷
关键词:
Electron density;
CT number;
Dose calculation;
D O I:
暂无
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
The CT numbers obtained from computed tomography (CT) are potentially useful for inhomogeneity correction in CT based treatment planning. The purpose of this study is to evaluate the variation of CT number from each scanner and the effect of this variation on photon dose calculations. Five kinds of CT scanners were used to obtain images of electron density calibration phantom (Gammex RMI 467). The images were transferred to treatment planning system (Pinnacle, USA) and drawing contour of each materials for obtaining the CT number. We obtained relationship between the CT numbers and electron densities from each CT scanner. In order to investigate the influence of CT number to dose calculation, patients' thoracic CT images were used. Difference of dose was evaluated with organ (Heart, Esophagus, Tumor, Lung, Liver, Vertebra body). The differences between CT numbers for each scanner were +/-2% in homogeneous medium and 9.5% in high density medium. The maximum dose difference was 0.48% for each organ. It acquired the phantom images inserted high density material in the water phantom. Comparing the doses calculated with CT images from each CT scanner, the maximum dose difference was 2.1% in 20 cm. There was not significant difference of CT number and dose in general condition but it was different in high density medium. The exact density to CT number conversion according to CT scanner is required to minimize the uncertainty of dose depends on CT number. Especially the each hospital with various CT scanners has to discriminate CT numbers for each CT scanner. Moreover a periodic quality assurance is required for reproducibility of CT number.