Standard Versus Low-Dose Computed Tomography for Assessment of Acetabular Fracture Reduction

被引:4
作者
Gibbs, Stephen [1 ]
Carney, John [2 ]
Erdman, Mary K. [2 ]
Telis, Alexander [3 ]
Lee, Adam K. [2 ]
Fleming, Mark E. [2 ]
Lee, Jackson [2 ]
White, Eric [4 ]
Marecek, Geoffrey S. [2 ]
机构
[1] Atrium Hlth, Dept Orthopaed Surg, Charlotte, NC USA
[2] Univ Southern Calif, Keck Sch Med, Dept Orthopaed Surg, 1520 San Pablo St,Suite 2000, Los Angeles, CA 90033 USA
[3] Providence Med Grp, Spokane, WA USA
[4] Univ Southern Calif, Keck Sch Med, Dept Radiol, Los Angeles, CA 90007 USA
关键词
acetabulum; posterior wall; low-dose CT; cadaveric; INTERNAL-FIXATION; POSTOPERATIVE CT; HIP; SCAN; RISK;
D O I
10.1097/BOT.0000000000001778
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: First, to assess the impact of varying computed tomography (CT) radiation dose on surgeon assessment of postfixation acetabular fracture reduction and malpositioned implants. Second, to quantify the accuracy of CT assessments compared with the experimentally set displacement in cadaver specimens. We hypothesized that a CT dose would not affect the assessments and that CT assessments would show a high concordance with known displacement. Methods: We created posterior wall acetabular fractures in 8 fresh-frozen cadaver hips and reduced them with varying combinations of step and gap displacement. The insertion of an intra-articular screw was randomized. Each specimen had a CT with standard (120 kV), intermediate (100 kV), and low-dose (80 kV) protocols, with and without metal artifact reduction postprocessing. Reviewers quantified gap and step displacement, overall reduction, quality of the scan, and identified intra-articular implants. Results: There were no significant differences between the CT dose protocols for assessment of gap, step, overall displacement, or the presence of intra-articular screws. Reviewers correctly categorized displacement as anatomic (0-1 mm), imperfect (2-3 mm), or poor (>3 mm) in 27.5%-57.5% of specimens. When the anatomic and imperfect categories were condensed into a single category, these scores improved to 52.5%-82.5%. Intra-articular screws were correctly identified in 56.3% of cases. Interobserver reliability was poor or moderate for all items. Reviewers rated the quality of most scans as "sufficient" (60.0%-72.5%); reviewers more frequently rated the low-dose CT as "inferior" (30.0%) and the standard dose CT as "excellent" (25%). Conclusion: A CT dose did not affect assessment of displacement, intra-articular screw penetration, or subjective rating of scan quality in the setting of a fixed posterior wall fracture.
引用
收藏
页码:462 / 468
页数:7
相关论文
共 50 条
  • [31] Computed Tomography in Cystic Fibrosis: Combining Low-Dose Techniques and Iterative Reconstruction
    Kahn, Johannes
    Kaul, David
    Grupp, Ulrich
    Boening, Georg
    Renz, Diane
    Staab, Doris
    Schreiter, Vera
    Streitparth, Florian
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 668 - 674
  • [32] Low-Dose Computed Tomography Screening in Relatives With a Family History of Lung Cancer
    Wang, Chi-Liang
    Hsu, Kuo-Hsuan
    Chang, Ya-Hsuan
    Ho, Chao-Chi
    Chiang, Chun-Ju
    Chen, Kun-Chieh
    Cheung, Yun-Chung
    Huang, Pei-Ching
    Chen, Yu-Ruei
    Chen, Chih-Yi
    Hsu, Chung-Ping
    Hsia, Jiun-Yi
    Chen, Hsuan-Yu
    Yang, Shi-Yi
    Li, Yao-Jen
    Yang, Tsung-Ying
    Tseng, Jeng-Sen
    Chuang, Cheng-Yen
    Hsiung, Chao A.
    Chen, Yuh-Min
    Huang, Ming-Shyan
    Yu, Chong-Jen
    Chen, Kuan-Yu
    Su, Wu-Chou
    Chen, Jeremy J. W.
    Yu, Sung-Liang
    Chen, Chien-Jen
    Yang, Pan-Chyr
    Tsai, Ying-Huang
    Chang, Gee-Chen
    JOURNAL OF THORACIC ONCOLOGY, 2023, 18 (11) : 1492 - 1503
  • [33] Low-Dose Chest Computed Tomography as a Screening Tool: Findings in 536 Aircrews
    Bang, Dong-Ho
    Lim, Daekeon
    Jeong, Ok-Man
    Hwang, Wi-Sub
    Jung, Ju-Yeon
    Lim, Jeongku
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2012, 83 (09): : 896 - 898
  • [34] Lung Cancer Field Cancerization: Implications for Screening by Low-Dose Computed Tomography
    Robles, Ana I.
    Harris, Curtis C.
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2017, 109 (07):
  • [35] Surveillance Low-Dose Chest Computed Tomography for Head and Neck Cancer Patients
    Bornstein, Sophia
    Wax, Mark
    Holland, John
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2012, 147 (03) : 401 - 403
  • [36] Lung Cancer Screening With Low-dose Computed Tomography An Analysis of the MEDCAC Decision
    Parker, Mark S.
    Groves, Robert C.
    Fowler, Alpha A., III
    Shepherd, Ray W.
    Cassano, Anthony D.
    Cafaro, Patricia L.
    Chestnut, Geoffrey T.
    JOURNAL OF THORACIC IMAGING, 2015, 30 (01) : 15 - 23
  • [37] Assessing the benefits and harms of low-dose computed tomography screening for lung cancer
    Pinsky, Paul F.
    LUNG CANCER MANAGEMENT, 2014, 3 (06) : 491 - 498
  • [38] Auto-Optimized Paralleled Sinogram Noise Reduction Method Based on Relative Quality Assessment for Low-Dose X-ray Computed Tomography
    Zhu, Yifan
    Ding, Yong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (01) : 278 - 282
  • [39] Metal artefact reduction in low-dose computed tomography: Benefits of tin prefiltration versus postprocessing of dual-energy datasets over conventional CT imaging
    Huflage, H.
    Grunz, J-P
    Hackenbroch, C.
    Halt, D.
    Luetkens, K. S.
    Schmidt, A. M. Alfred
    Patzer, T. S.
    Ergun, S.
    Bley, T. A.
    Kunz, A. S.
    RADIOGRAPHY, 2022, 28 (03) : 690 - 696
  • [40] Advances in Imaging (Intraop Cone-Beam Computed Tomography, Synthetic Computed Tomography, Bone Scan, Low-Dose Protocols)
    Jankowski, Pawel P.
    Chan, Justin P.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2024, 35 (02) : 161 - 172