Standard Versus Low-Dose Computed Tomography for Assessment of Acetabular Fracture Reduction

被引:4
作者
Gibbs, Stephen [1 ]
Carney, John [2 ]
Erdman, Mary K. [2 ]
Telis, Alexander [3 ]
Lee, Adam K. [2 ]
Fleming, Mark E. [2 ]
Lee, Jackson [2 ]
White, Eric [4 ]
Marecek, Geoffrey S. [2 ]
机构
[1] Atrium Hlth, Dept Orthopaed Surg, Charlotte, NC USA
[2] Univ Southern Calif, Keck Sch Med, Dept Orthopaed Surg, 1520 San Pablo St,Suite 2000, Los Angeles, CA 90033 USA
[3] Providence Med Grp, Spokane, WA USA
[4] Univ Southern Calif, Keck Sch Med, Dept Radiol, Los Angeles, CA 90007 USA
关键词
acetabulum; posterior wall; low-dose CT; cadaveric; INTERNAL-FIXATION; POSTOPERATIVE CT; HIP; SCAN; RISK;
D O I
10.1097/BOT.0000000000001778
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: First, to assess the impact of varying computed tomography (CT) radiation dose on surgeon assessment of postfixation acetabular fracture reduction and malpositioned implants. Second, to quantify the accuracy of CT assessments compared with the experimentally set displacement in cadaver specimens. We hypothesized that a CT dose would not affect the assessments and that CT assessments would show a high concordance with known displacement. Methods: We created posterior wall acetabular fractures in 8 fresh-frozen cadaver hips and reduced them with varying combinations of step and gap displacement. The insertion of an intra-articular screw was randomized. Each specimen had a CT with standard (120 kV), intermediate (100 kV), and low-dose (80 kV) protocols, with and without metal artifact reduction postprocessing. Reviewers quantified gap and step displacement, overall reduction, quality of the scan, and identified intra-articular implants. Results: There were no significant differences between the CT dose protocols for assessment of gap, step, overall displacement, or the presence of intra-articular screws. Reviewers correctly categorized displacement as anatomic (0-1 mm), imperfect (2-3 mm), or poor (>3 mm) in 27.5%-57.5% of specimens. When the anatomic and imperfect categories were condensed into a single category, these scores improved to 52.5%-82.5%. Intra-articular screws were correctly identified in 56.3% of cases. Interobserver reliability was poor or moderate for all items. Reviewers rated the quality of most scans as "sufficient" (60.0%-72.5%); reviewers more frequently rated the low-dose CT as "inferior" (30.0%) and the standard dose CT as "excellent" (25%). Conclusion: A CT dose did not affect assessment of displacement, intra-articular screw penetration, or subjective rating of scan quality in the setting of a fixed posterior wall fracture.
引用
收藏
页码:462 / 468
页数:7
相关论文
共 50 条
  • [1] Standard versus low-dose computed tomography for assessment of acetabular fracture reduction using novel step and gap measurement technique
    Robles, Abrianna S.
    Piple, Amit S.
    DeSanto, Donald J.
    Lamb, Ashley
    Gibbs, Stephen J.
    Heckmann, Nathanael D.
    Marecek, Geoffrey S.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (08) : 3703 - 3709
  • [2] Standard versus low-dose computed tomography for assessment of acetabular fracture reduction using novel step and gap measurement technique
    Abrianna S. Robles
    Amit S. Piple
    Donald J. DeSanto
    Ashley Lamb
    Stephen J. Gibbs
    Nathanael D. Heckmann
    Geoffrey S. Marecek
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 3703 - 3709
  • [3] Computed tomography versus plain radiography assessment of acetabular fracture reduction is more predictive for native hip survivorship
    Verbeek, Diederik O.
    van der List, Jelle P.
    Helfet, David L.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (12) : 1667 - 1672
  • [4] Noise Simulation for Low-dose Computed Tomography
    Fan, Yi
    Zamyatin, Alexander A.
    Nakanishi, Satoru
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3641 - 3643
  • [5] Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
    Duarte, Marcio Luis
    dos Santos, Lucas Ribeiro
    Bulle Oliveira, Acary Souza
    Iared, Wagner
    Peccin, Maria Stella
    SAO PAULO MEDICAL JOURNAL, 2021, 139 (04): : 388 - 397
  • [6] Noise reduction for low-dose X-ray computed tomography with fuzzy filter
    Gui, Zhi-guo
    Liu, Yi
    OPTIK, 2012, 123 (13): : 1207 - 1211
  • [7] Low-dose chest computed tomography screening of subjects exposed to asbestos
    Kato, Katsuya
    Gemba, Kenichi
    Ashizawa, Kazuto
    Arakawa, Hiroaki
    Honda, Satoshi
    Noguchi, Naomi
    Honda, Sumihisa
    Fujimoto, Nobukazu
    Kishimoto, Takumi
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 124 - 128
  • [8] Diagnostic Usefulness of Low-Dose Nonenhanced Computed Tomography With Coronal Reformations in Patients With Suspected Acute Appendicitis: A Comparison With Standard-Dose Computed Tomography
    Yun, Seong Jong
    Kim, Hyun Cheol
    Yang, Dal Mo
    Kim, Sang Won
    Rhee, Sun Jung
    Shin, Jong Soo
    Ahn, Sung Eun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (03) : 485 - 492
  • [9] A sinogram denoising algorithm for low-dose computed tomography
    Karimi, Davood
    Deman, Pierre
    Ward, Rabab
    Ford, Nancy
    BMC MEDICAL IMAGING, 2016, 16
  • [10] A sinogram denoising algorithm for low-dose computed tomography
    Davood Karimi
    Pierre Deman
    Rabab Ward
    Nancy Ford
    BMC Medical Imaging, 16