Comparison of cardiac output derived from FloTrac/Vigileo and impedance cardiography during major abdominal surgery

被引:11
作者
Kim, Ji-Yeon [1 ]
Kim, Bo-Ram [1 ]
Lee, Kang-Hun [1 ]
Kim, Kyung-Woo [1 ]
Kim, Jun-Hyun [1 ]
Lee, Sang-Il [1 ]
Kim, Kyung-Tae [1 ]
Choe, Won-Joo [1 ]
Park, Jang-Su [1 ]
Kim, Jung-Won [1 ]
机构
[1] Inje Univ, Ilsan Paik Hosp, Dept Anaesthesiol & Pain Med, Goyang, South Korea
关键词
Cardiac output; impedance cardiography; niccomo; continuous haemodynamic monitoring; FloTrac; Vigileo; THORACIC ELECTRICAL BIOIMPEDANCE; PRESSURE WAVE-FORM; NONINVASIVE ASSESSMENT; CLINICAL MEASUREMENT; ASSESSING AGREEMENT; HEART-FAILURE; THERMODILUTION; EQUIVALENCE; INDEX;
D O I
10.1177/0300060513487649
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives Impedance cardiography (ICG) is a noninvasive technique that provides reasonably accurate measurements of cardiac output, but the usefulness of ICG in patients undergoing open abdominal surgery has not been validated. Methods Cardiac output was measured while patients underwent open gastrectomy using an ICG monitor (niccomo; ICG-CO); the results were compared with those measured using a FloTrac/Vigileo monitor (Flo-CO), which measures cardiac output by analysing the arterial waveform. Data collection commenced at the beginning of anaesthetic induction and continued until the patient was awake. Data were compared using the Bland-Altman analysis, and the clinical significance of the difference between the two methods was evaluated by calculating the percentage error (%). Results Eleven patients were monitored during surgery. The bias of the Flo-CO and ICG-CO values was -0.45l/min. The upper and lower limits of agreement were 0.96l/min and -1.85l/min, respectively. The percentage error was 28.5%. Electrocautery induced interference that transiently impaired the performance of the ICG monitor. Conclusions ICG provided useful information in evaluating the cardiac output of patients during abdominal surgery.
引用
收藏
页码:1342 / 1349
页数:8
相关论文
共 22 条
[11]   Noninvasive Assessment of Cardiac Index in Healthy Volunteers: A Comparison Between Thoracic Impedance Cardiography and Doppler Echocardiography [J].
Fellahi, Jean-Luc ;
Caille, Vincent ;
Charron, Cyril ;
Deschamps-Berger, Pierre-Herve ;
Vieillard-Baron, Antoine .
ANESTHESIA AND ANALGESIA, 2009, 108 (05) :1553-1559
[12]   Cardiac output derived from arterial pressure waveform [J].
Mayer, Jochen ;
Suttner, Stefan .
CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (06) :804-808
[13]   Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications [J].
Moshkovitz, Y ;
Kaluski, E ;
Milo, O ;
Vered, Z ;
Cotter, G .
CURRENT OPINION IN CARDIOLOGY, 2004, 19 (03) :229-237
[14]  
Osypka M J, 1999, AACN Clin Issues, V10, P385, DOI 10.1097/00044067-199908000-00008
[15]  
Perrino A C Jr, 1994, J Cardiothorac Vasc Anesth, V8, P24, DOI 10.1016/1053-0770(94)90007-8
[16]   Increased risk associated with pulmonary artery catheterization in the medical intensive care unit [J].
Peters, SG ;
Afessa, B ;
Decker, PA ;
Schroeder, DR ;
Offord, KP ;
Scott, JP .
JOURNAL OF CRITICAL CARE, 2003, 18 (03) :166-171
[17]   Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery [J].
Sageman, WS ;
Riffenburgh, RH ;
Spiess, BD .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (01) :8-14
[18]  
SHOEMAKER WC, 1994, CRIT CARE MED, V22, P1907
[19]   RETRACTED: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery:: a comparison with pulmonary artery thermodilution (Retracted article. See vol. 37, pg. 1232, 2011) [J].
Suttner, Stefan ;
Schoellhorn, Thilo ;
Boldt, Joachim ;
Mayer, Jochen ;
Roehm, Kerstin D. ;
Lang, Katrin ;
Piper, Swen N. .
INTENSIVE CARE MEDICINE, 2006, 32 (12) :2053-2058
[20]   Cardiac Output Derived From Arterial Pressure Waveform Analysis: Validation of the Third-Generation Software in Patients Undergoing Orthotopic Liver Transplantation [J].
Tsai, Y. -F. ;
Su, B. -C. ;
Lin, C. -C. ;
Liu, F. -C. ;
Lee, W. -C. ;
Yu, H. -P. .
TRANSPLANTATION PROCEEDINGS, 2012, 44 (02) :433-437