Value of Augmented Reality-Enhanced Transesophageal Echocardiography (TEE) for Determining Optimal Annuloplasty Ring Size During Mitral Valve Repair

被引:35
作者
Ender, Joerg [1 ]
Koncar-Zeh, Jasmina
Mukherjee, Chirojit
Jacobs, Stephan
Borger, Michael A.
Viola, Christoph
Gessat, Michael
Fassl, Jens
Mohr, Friedrich W.
Falk, Volkmar
机构
[1] Univ Leipzig, Dept Anesthesiol & Intens Care Med 2, Leipzig Heart Ctr, Innovat Ctr Comp Assisted Surg, D-04289 Leipzig, Germany
关键词
D O I
10.1016/j.athoracsur.2008.07.073
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Mitral valve (MV) annuloplasty is an integral part of MV repair, but sizing under direct vision is occasionally challenging. Furthermore, traditional sizing is not possible for percutaneous MV repair techniques. This study compared augmented reality-enhanced three-dimensional (3D) transesophageal echocardiography ( TEE) for determining MV annuloplasty size with conventional surgical sizing. Methods. In patients undergoing elective MV repair, a 3D MV reconstruction was performed using TEE. Modified 4D valve assessment software was used to create 3D computer-aided design models of standard annuloplasty rings ( 28 to 36 mm), which were stored in a digital database. These virtual 3D annuloplasty ring templates were superimposed on the preoperative 3D TEE reconstructions of the MV, and results were compared with conventional sizing under direct vision. A post hoc validation of the 3D models was performed using the implanted rings as a control. The echocardiographer was blinded to the implanted ring size. Results. The study included 50 patients. The correlation between the selected 3D annuloplasty ring template and the implanted annuloplasty ring size was 0.83. Thirty ring templates ( 60%) were the same size as the implanted annuloplasty ring, 19 templates ( 38%) differed by +/-2 mm in size, and 1 template differed by +4 mm. Postoperatively, the validation protocol revealed a correlation of 0.94 between the size of the ring templates and the implanted annuloplasty prostheses. Conclusions. Augmented reality-enhanced TEE for determining optimal annuloplasty ring size during MV repair correlates well with conventional surgical sizing and may facilitate future percutaneous MV repair techniques.
引用
收藏
页码:1473 / 1479
页数:8
相关论文
共 21 条
[1]  
Abdi H., 2007, ENCY MEASUREMENT STA, P304
[2]   Midterm results of the edge-to-edge technique for complex mitral valve repair [J].
Brinster, DR ;
Unic, D ;
D'Ambra, MN ;
Nathan, N ;
Cohn, LH .
ANNALS OF THORACIC SURGERY, 2006, 81 (05) :1612-1617
[3]  
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[4]   Echocardiographic assessment of the mechanisms of correction of bileaflet prolapse causing mitral regurgitation with only posterior leaflet repair surgery [J].
Cho, L ;
Gillinov, AM ;
Cosgrove, DM ;
Griffin, BP ;
Garcia, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (12) :1349-1351
[5]  
Choo SJ, 1998, J HEART VALVE DIS, V7, P593
[6]  
Cook RC, 2006, J HEART VALVE DIS, V15, P521
[7]   Value of Augmented Reality-Enhanced Transesophageal Echocardiography (TEE) for Determining Optimal Annuloplasty Ring Size During Mitral Valve Repair [J].
Ender, Joerg ;
Koncar-Zeh, Jasmina ;
Mukherjee, Chirojit ;
Jacobs, Stephan ;
Borger, Michael A. ;
Viola, Christoph ;
Gessat, Michael ;
Fassl, Jens ;
Mohr, Friedrich W. ;
Falk, Volkmar .
ANNALS OF THORACIC SURGERY, 2008, 86 (05) :1473-1479
[8]  
FELDMAN T, 2007, J INTERV CARDIOL, V20, P495
[9]   INTRAOPERATIVE EVALUATION OF MITRAL-VALVE REGURGITATION AND REPAIR BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - INCIDENCE AND SIGNIFICANCE OF SYSTOLIC ANTERIOR MOTION [J].
FREEMAN, WK ;
SCHAFF, HV ;
KHANDHERIA, BK ;
OH, JK ;
ORSZULAK, TA ;
ABEL, MD ;
SEWARD, JB ;
TAJIK, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) :599-609
[10]   Early results of posterior leaflet folding plasty for mitral valve reconstruction [J].
Grossi, EA ;
Galloway, AC ;
Kallenbach, K ;
Miller, JS ;
Esposito, R ;
Schwartz, DS ;
Colvin, SB .
ANNALS OF THORACIC SURGERY, 1998, 65 (04) :1057-1059