Batch injection analysis with electrochemical detection for the simultaneous determination of the diuretics furosemide and hydrochlorothiazide in synthetic urine and pharmaceutical samples

被引:26
作者
Silva, Eduardo Fonseca [1 ]
Tanaka, Auro Atsushi [2 ]
Fernandes, Ridvan Nunes [2 ]
Munoz, Rodrigo Alejandro Abarza [3 ,4 ]
Silva, Iranaldo Santos da [1 ]
机构
[1] Univ Fed Maranhao, Ctr Ciencias Exatas & Tecnol, Dept Tecnol Quim, BR-65080805 Sao Luis, MA, Brazil
[2] Univ Fed Maranhao, Ctr Ciencias Exatas & Tecnol, Dept Quim, BR-65080805 Sao Luis, MA, Brazil
[3] Inst Nacl Ciencia & Tecnol Bioanalit, Caixa Postal 6154, BR-13083970 Campinas, SP, Brazil
[4] Univ Fed Uberlandia, Inst Quim, BR-38400902 Uberlandia, MG, Brazil
关键词
Furosemide; Hydrochlorothiazide; Boron-doped diamond; Flow analysis; Anti-doping; BORON-DOPED DIAMOND; PULSE AMPEROMETRIC DETECTION; VOLTAMMETRIC DETERMINATION; FLOW-INJECTION; ELECTRODE; PHARMACOKINETICS; FORMULATIONS; AMLODIPINE; OXIDATION; GRAPHITE;
D O I
10.1016/j.microc.2020.105027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This works shows the combination of batch-injection analysis with multiple-pulse amperometric detection (BIAMPA) for the determination of the diuretics furosemide (FRD) and hydrochlorothiazide (HCT) in urine and pharmaceutical samples. Under optimized electrolyte conditions (0.04 mol L-1 Britton-Robinson buffer solution at pH 4.0) FRD was oxidized at + 1.10 V and both compounds were oxidized at + 1.30 V. The MPA detection involves the continuous application of two potential pulses as a function of time to determine FRD at the first potential and HCT at the second after subtracting the FRD current obtained at the second potential. A correction factor was needed because the current of FRD at both potentials was different. A boron-doped diamond working electrode was selected for the simultaneous determination as its surface is less susceptive to fouling. The compounds exhibited a linear response range of 2 to 100 mu mol L-1 for HCT (r = 0.9990) and 2 to 300 mu mol L-1 for FRD (r = 0.9993), satisfactory repeatability (RSD lower than 5% for n = 30), detection limits of 0.65 mu mol L-1 for FRD and 0.63 mu mol L-1 for HCT, and analytical frequency of 130 injections per hour. The proposed method was applied for the analysis of synthetic urine samples spiked with both compounds and proper recovery values were obtained (95-110%), confirming the potential application for anti-doping analyses. Moreover, the proposed method was compared to UV-Vis spectrophotometry for the analysis of pharmaceutical formulations and they were found to be statistically similar at the 95% confidence level.
引用
收藏
页数:8
相关论文
共 43 条
[1]   Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids [J].
Alghamdi, Ali F. .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (03) :363-369
[2]   Bar adsorptive microextraction technique - application for the determination of pharmaceuticals in real matrices [J].
Almeida, Carlos ;
Ahmad, Samir ;
Nogueira, Jose Manuel .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (08) :2093-2106
[3]  
[Anonymous], 2016, TALANTA, V146, P670, DOI [10.1016/j.talanta.2015.06.048., DOI 10.1016/J.TALANTA.2015.06.048]
[4]   Batch injection analysis with amperometric detection: application for simultaneous analysis using a single working electrode [J].
Bezerra da Silva, Rodrigo Amorim ;
Gimenes, Denise Tofanello ;
Tormin, Thiago Faria ;
Abarza Munoz, Rodrigo Alejandro ;
Richter, Eduardo Mathias .
ANALYTICAL METHODS, 2011, 3 (12) :2804-2808
[5]   Application of LC-ESI-MS-MS for detection of synthetic adulterants in herbal remedies [J].
Bogusz, MJ ;
Hassan, H ;
Ai-Enazi, E ;
Ibrahim, Z ;
Al-Tufail, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) :554-564
[6]  
Brasil, 2010, Farmacopeia Brasileira, 5a Edicao, V2, P1, DOI DOI 10.1590/S0102-33062006000100002
[7]   Electrochemical oxidation of loop diuretic furosemide in aqueous acid medium and its analytical application [J].
Bukkitgar, Shikandar D. ;
Shetti, Nagaraj P. .
COGENT CHEMISTRY, 2016, 2
[8]   3D printing for electroanalysis: From multiuse electrochemical cells to sensors [J].
Cardoso, Rafael M. ;
Mendonca, Dianderson M. H. ;
Silva, Weberson P. ;
Silva, Murilo N. T. ;
Nossol, Edson ;
da Silva, Rodrigo A. B. ;
Richter, Eduardo M. ;
Munoz, Rodrigo A. A. .
ANALYTICA CHIMICA ACTA, 2018, 1033 :49-57
[9]   Rapid analysis of furosemide in human urine by capillary electrophoresis with laser-induced fluorescence and electrospray ionization-ion trap mass spectrometric detection [J].
Caslavska, J ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2) :207-216
[10]   Determination of the catechin contents of bioactive plant extracts using disposable screen-printed carbon electrodes in a batch injection analysis (BIA) system [J].
Correa Ribeiro, Geyse Adriana ;
da Rocha, Claudia Quintino ;
Veloso, William Barros ;
Fernandes, Ridvan Nunes ;
da Silva, Iranaldo Santos ;
Tanaka, Auro Atsushi .
MICROCHEMICAL JOURNAL, 2019, 146 :1249-1254