Counting White Blood Cells from a Blood Smear Using Fourier Ptychographic Microscopy

被引:72
作者
Chung, Jaebum [1 ]
Ou, Xiaoze [1 ]
Kulkarni, Rajan P. [2 ]
Yang, Changhuei [1 ,3 ]
机构
[1] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
[2] Univ Calif Los Angeles, Div Dermatol, Los Angeles, CA 90024 USA
[3] CALTECH, Dept Bioengn, Pasadena, CA 91125 USA
关键词
HEART-DISEASE; MORTALITY; CORONARY; FLOW;
D O I
10.1371/journal.pone.0133489
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
White blood cell (WBC) count is a valuable metric for assisting with diagnosis or prognosis of various diseases such as coronary heart disease, type 2 diabetes, or infection. Counting WBCs can be done either manually or automatically. Automatic methods are capable of counting a large number of cells to give a statistically more accurate reading of the WBC count of a sample, but the specialized equipment tends to be expensive. Manual methods are inexpensive since they only involve a conventional light microscope setup. However, it is more laborious and error-prone because the small field-of-view (FOV) of the microscope necessitates mechanical scanning of a specimen for counting an adequate number of WBCs. Here, we investigate the use of Fourier ptychographic microscopy (FPM) to bypass these issues of the manual methods. With a 2x objective, FPM can provide a FOV of 120 mm(2) with enhanced resolution comparable to that of a 20x objective, which is adequate for non-differentially counting WBCs in just one FOV. A specialist was able to count the WBCs in FPM images with 100% accuracy compared to the count as determined from conventional microscope images. An automatic counting algorithm was also developed to identify WBCs from FPM's captured images with 95% accuracy, paving the way for a cost-effective WBC counting setup with the advantages of both the automatic and manual counting methods.
引用
收藏
页数:10
相关论文
共 23 条
[1]  
[Anonymous], BASIC MED HISTOLOGY
[2]   Association between white blood cell count, epicardial blood flow, myocardial perfusion, and clinical outcomes in the setting of acute myocardial infarction - A Thrombolysis in Myocardial Infarction 10 substudy [J].
Barron, HV ;
Cannon, CP ;
Murphy, SA ;
Braunwald, E ;
Gibson, CM .
CIRCULATION, 2000, 102 (19) :2329-2334
[3]  
Bellwood B, 2013, VET TECHNICIANS HDB
[4]   Mobile Phone Based Clinical Microscopy for Global Health Applications [J].
Breslauer, David N. ;
Maamari, Robi N. ;
Switz, Neil A. ;
Lam, Wilbur A. ;
Fletcher, Daniel A. .
PLOS ONE, 2009, 4 (07)
[5]   White blood cell count: An independent predictor of coronary heart disease mortality among a national cohort [J].
Brown, DW ;
Giles, WH ;
Croft, JB .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2001, 54 (03) :316-322
[6]  
Fritsma GA, 2008, HEMATOLOGY CLIN PRIN
[7]   Digital Imaging in Pathology: Whole-Slide Imaging and Beyond [J].
Ghaznavi, Farzad ;
Evans, Andrew ;
Madabhushi, Anant ;
Feldman, Michael .
ANNUAL REVIEW OF PATHOLOGY: MECHANISMS OF DISEASE, VOL 8, 2013, 8 :331-359
[8]   PROGNOSTIC IMPORTANCE OF THE WHITE BLOOD-CELL COUNT FOR CORONARY, CANCER, AND ALL-CAUSE MORTALITY [J].
GRIMM, RH ;
NEATON, JD ;
LUDWIG, W .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 254 (14) :1932-1937
[9]   A phase space model of Fourier ptychographic microscopy [J].
Horstmeyer, Roarke ;
Yang, Changhuei .
OPTICS EXPRESS, 2014, 22 (01) :338-358
[10]   Microfluidics for flow cytometric analysis of cells and particles [J].
Huh, D ;
Gu, W ;
Kamotani, Y ;
Grotberg, JB ;
Takayama, S .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (03) :R73-R98