Is Distal Locking Necessary? A Biomechanical Investigation of Intramedullary Nailing Constructs for Intertrochanteric Fractures

被引:29
作者
Gallagher, David [1 ]
Adams, Brock [1 ]
El-Gendi, Hebah [1 ]
Patel, Ashish [1 ]
Grossman, Lauren [1 ]
Berdia, Jay [1 ]
Korshunov, Yevgeniy [1 ]
Goldman, Ariel [1 ]
机构
[1] Suny Downstate Med Ctr, Dept Orthopaed Surg & Rehabil Med, Brooklyn, NY 11203 USA
关键词
distal locking; intertrochanteric fracture; rotational loads;
D O I
10.1097/BOT.0b013e31827cd5bd
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Unstable intertrochanteric fractures in the elderly occur frequently. Several studies have evaluated the biomechanical impact of distally locking long cephalomedullary nails under axial loading; however, the impact of torsional loading has not been investigated. The purpose of this study is to determine the rotational load to failure of unstable intertrochanteric fractures treated with long cephalomedullary nails, with and without distal interlocking. Methods: Eleven paired cadaveric femora treated with long cephalomedullary nails were randomized into 2 groups. Group 1 was left unlocked, whereas group 2 was distally locked. Osteotomies were completed to create unstable 4-part fractures. The femora were anatomically fixed proximally and distally and secured to the biomechanical testing machine to undergo internal rotation. Torque and rotational angle were measured until failure. Results: The locked group had a mean maximal torsional load of 57.9 +/- 19.0 N center dot m and a mean rotational stiffness of 119.4 +/- 35.7 N center dot m/rad. The femora treated with unlocked nails had a mean maximal torsional load of 29.1 +/- 12.2 N center dot m and a mean rotational stiffness of 77.2 +/- 31.3 N center dot m/rad. Distal locking resulted in a significant increase in maximal rotational load (P = 0.001) and rotational stiffness (P = 0.004) before failure. No significant difference was found in mean rotational angle at failure between groups (26.0 +/- 9.6 degrees, P = 0.263). Conclusions: Maximal torsional load to failure for the unlocked group is within the functional range of rotational loads experienced at the hip for an average adult. The results show that distal locking significantly increases rotational load to failure. The authors highly recommend routine use of distal interlocking screws during cephalomedullary nail placement in unstable intertrochanteric fractures.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 22 条
[11]   Surgical Management of Hip Fractures: An Evidence-based Review of the Literature. II: Intertrochanteric Fractures [J].
Kaplan, Kevin ;
Miyamoto, Ryan ;
Levine, Brett R. ;
Egol, Kenneth A. ;
Zuckerman, Joseph D. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (11) :665-673
[12]   Does timing of surgery matter in fragility hip fractures? [J].
Leung, F. ;
Lau, T. W. ;
Kwan, K. ;
Chow, S. P. ;
Kung, A. W. C. .
OSTEOPOROSIS INTERNATIONAL, 2010, 21 :S529-S534
[13]   Distal unlocked proximal femoral intramedullary nailing for intertrochanteric femur fractures [J].
Ozkan, Korhan ;
Unay, Koray ;
Demircay, Can ;
Cakir, Mustafa ;
Eceviz, Engin .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) :1397-1400
[14]   Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail - A randomised study comparing post-operative rehabilitation [J].
Pajarinen, J ;
Lindahl, J ;
Michelsson, O ;
Savolainen, V ;
Hirvensalo, E .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (01) :76-81
[15]   Integrity of the lateral femoral wall in intertrochanteric hip fractures: An important predictor of a reoperation [J].
Palm, Henrik ;
Jacobsen, Steffen ;
Sonne-Holm, Stig ;
Gebuhr, Peter .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03) :470-475
[16]   The biomechanics of human femurs in axial and torsional loading: Comparison of finite element analysis, human cadaveric femurs, and synthetic femurs [J].
Papini, M. ;
Zdero, R. ;
Schemitsch, E. H. ;
Zalzal, P. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (01) :12-19
[17]   Implant-related fractures of the femur following hip fracture surgery [J].
Robinson, CM ;
Adams, CI ;
Craig, M ;
Doward, W ;
Clarke, MCC ;
Auld, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (07) :1116-1122
[18]   A BIOMECHANICAL EVALUATION OF THE GAMMA-NAIL [J].
ROSENBLUM, SF ;
ZUCKERMAN, JD ;
KUMMER, FJ ;
TAM, BS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :352-357
[19]   Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate -: A prospective, randomized study [J].
Sadowski, C ;
Lübbeke, A ;
Saudan, M ;
Riand, N ;
Stern, R ;
Hoffmeyer, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (03) :372-381
[20]   The forces in the distal femur and the knee during walking and other activities measured by telemetry [J].
Taylor, SJG ;
Walker, PS ;
Perry, JS ;
Cannon, SR ;
Woledge, R .
JOURNAL OF ARTHROPLASTY, 1998, 13 (04) :428-437