Is Distal Locking Necessary? A Biomechanical Investigation of Intramedullary Nailing Constructs for Intertrochanteric Fractures

被引:29
作者
Gallagher, David [1 ]
Adams, Brock [1 ]
El-Gendi, Hebah [1 ]
Patel, Ashish [1 ]
Grossman, Lauren [1 ]
Berdia, Jay [1 ]
Korshunov, Yevgeniy [1 ]
Goldman, Ariel [1 ]
机构
[1] Suny Downstate Med Ctr, Dept Orthopaed Surg & Rehabil Med, Brooklyn, NY 11203 USA
关键词
distal locking; intertrochanteric fracture; rotational loads;
D O I
10.1097/BOT.0b013e31827cd5bd
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Unstable intertrochanteric fractures in the elderly occur frequently. Several studies have evaluated the biomechanical impact of distally locking long cephalomedullary nails under axial loading; however, the impact of torsional loading has not been investigated. The purpose of this study is to determine the rotational load to failure of unstable intertrochanteric fractures treated with long cephalomedullary nails, with and without distal interlocking. Methods: Eleven paired cadaveric femora treated with long cephalomedullary nails were randomized into 2 groups. Group 1 was left unlocked, whereas group 2 was distally locked. Osteotomies were completed to create unstable 4-part fractures. The femora were anatomically fixed proximally and distally and secured to the biomechanical testing machine to undergo internal rotation. Torque and rotational angle were measured until failure. Results: The locked group had a mean maximal torsional load of 57.9 +/- 19.0 N center dot m and a mean rotational stiffness of 119.4 +/- 35.7 N center dot m/rad. The femora treated with unlocked nails had a mean maximal torsional load of 29.1 +/- 12.2 N center dot m and a mean rotational stiffness of 77.2 +/- 31.3 N center dot m/rad. Distal locking resulted in a significant increase in maximal rotational load (P = 0.001) and rotational stiffness (P = 0.004) before failure. No significant difference was found in mean rotational angle at failure between groups (26.0 +/- 9.6 degrees, P = 0.263). Conclusions: Maximal torsional load to failure for the unlocked group is within the functional range of rotational loads experienced at the hip for an average adult. The results show that distal locking significantly increases rotational load to failure. The authors highly recommend routine use of distal interlocking screws during cephalomedullary nail placement in unstable intertrochanteric fractures.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 22 条
[1]   Intertrochanteric-subtrochanteric fractures:: Treatment with the long gamma nail [J].
Barquet, A ;
Francescoli, L ;
Rienzi, D ;
López, L .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (05) :324-328
[2]   THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[3]   A BIOMECHANICAL EVALUATION OF THE LONG STEM INTRAMEDULLARY HIP SCREW [J].
BOSTROM, MPG ;
LYDEN, JP ;
ERNBERG, JJ ;
MISSRI, AAE ;
BERBERIAN, WS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) :45-52
[4]  
Brumback RJ, 1996, CLIN ORTHOP RELAT R, P292
[5]   Influence of formalin fixation on the biomechanical properties of human diaphyseal bone [J].
Burkhart, Klaus J. ;
Nowak, Tobias E. ;
Blum, Jochen ;
Kuhn, Sebastian ;
Welker, Marcel ;
Sternstein, Werner ;
Mueller, Lars P. ;
Rommens, Pol M. .
BIOMEDIZINISCHE TECHNIK, 2010, 55 (06) :361-365
[6]   Geographic variation in device use for intertrochanteric hip fractures [J].
Forte, Mary L. ;
Virnig, Beth A. ;
Kane, Robert L. ;
Durham, Sara ;
Bhandari, Mohit ;
Feldman, Roger ;
Swiontkowski, Marc F. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :691-699
[7]  
Fry AC, 2003, J STRENGTH COND RES, V17, P629
[8]  
Haidukewych GJ, 2009, J BONE JOINT SURG AM, V91A, P712
[9]   Reverse obliquity fractures of the intertrochanteric region of the femur [J].
Haidukewych, GT ;
Israel, TA ;
Berry, DJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (05) :643-650
[10]   Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures - A prospective, randomized study of one hundred patients [J].
Hardy, DCR ;
Descamps, PY ;
Krallis, P ;
Fabeck, L ;
Smets, P ;
Bertens, CL ;
Delince, PE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :618-630