Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry

被引:69
|
作者
Wang, JH [1 ]
Hansen, EH [1 ]
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
关键词
extraction-back extraction; sequential injection; electrothermal atomic absorption spectrometry; assay of certified reference materials; cadmium;
D O I
10.1016/S0003-2670(02)00026-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium pyrrolidinedithiocarbamate (APDC) in citrate buffer and the chelate is extracted into isobutyl methyl ketone (IBMK), which is separated from the aqueous phase by means of a newly designed dual-conical gravitational phase separator. A metered amount of the organic eluate is aspirated and stored in the PTFE holding coil (HC) of the SI-system. Afterwards, it is dispensed and mixed with an aqueous back extractant of dilute nitric acid containing Hg(II) ions as stripping agent, thereby facilitating a rapid metal-exchange reaction with the APDC ligand and transfer of the Cd into the aqueous phase. The aqueous phase is separated in a second dual-conical gravitational phase separator, and 30 mul of it is entrapped and metered in a sample loop (SL) and subsequently introduced via air segmentation into the graphite tube for analyte quantification. The ETAAS determination is performed in parallel with the separation/preconcentration process of the ensuing sample. An enrichment factor of 21.4, a detection limit of 2.7 ng l(-1), along with a sampling frequency of 13 h(-1) were obtained at a sample flow rate of 6.0 ml min(-1). The precision (R.S.D.) at the 0.4 mug l(-1) level was 1.8% as compared to 3.2% when quantifying the organic extractant directly. The applicability of the procedure is demonstrated for the determination of trace levels of cadmium in three certified reference materials. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 292
页数:10
相关论文
共 50 条
  • [1] A sequential injection on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry
    Xu, ZR
    Pan, HY
    Xu, SK
    Fang, ZL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (03) : 213 - 219
  • [2] On-line flow injection solvent extraction for electrothermal atomic absorption spectrometry: Determination of nickel in biological samples
    Tao, G
    Fang, Z
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (14) : 1747 - 1755
  • [3] Silk fibroin as a sorbent for on-line extraction and preconcentration of copper with detection by electrothermal atomic absorption spectrometry
    Chen, Xu-Wei
    Huang, Lin-Lin
    He, Rong-Huan
    TALANTA, 2009, 78 (01) : 71 - 75
  • [4] Development of on-line single-drop micro-extraction sequential injection system for electrothermal atomic absorption spectrometric determination of trace metals
    Anthemidis, Aristidis N.
    Adam, Ibrahim S. I.
    ANALYTICA CHIMICA ACTA, 2009, 632 (02) : 216 - 220
  • [5] Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples
    Giakisikli, Georgia
    Quezada, Alejandro Ayala
    Tanaka, Junpei
    Anthemidis, Aristidis N.
    Murakami, Hiroya
    Teshima, Norio
    Sakai, Tadao
    ANALYTICAL SCIENCES, 2015, 31 (05) : 383 - 389
  • [6] Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples
    Georgia Giakisikli
    Alejandro Ayala Quezada
    Junpei Tanaka
    Aristidis N. Anthemidis
    Hiroya Murakami
    Norio Teshima
    Tadao Sakai
    Analytical Sciences, 2015, 31 : 383 - 389
  • [7] Indirect determination of nitrate by electrothermal atomic absorption spectrometry using an on-line cadmium microcolumn
    Alonso, EV
    Cordero, MTS
    Torres, MPC
    de Torres, AG
    Pavón, JMC
    ANALYST, 1998, 123 (07) : 1561 - 1564
  • [8] Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry Using Single Drop Micro Extraction in Real Samples
    Chamsaz, M.
    Arbab-Zavar, M. H.
    Riazi, M. M.
    Takjoo, R.
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (02) : 547 - 550
  • [9] Flow injection on-line solid phase extraction for ultra-trace lead determination with hydride generation electrothermal atomic absorption spectrometry
    Sanchez Trujillo, Irene
    Alonso Castillo, Manuel L.
    Cano Pavon, Jose Manuel
    Vereda Alonso, Elisa I.
    Garcia de Torres, Amparo
    ANALYTICAL METHODS, 2013, 5 (10) : 2551 - 2557
  • [10] Determination of Trace Cadmium in Food Samples by Electrothermal Atomic Absorption Spectrometry After Cloud Point Extraction
    Xiang, G. Q.
    Wen, S. P.
    Wu, X. Y.
    Liu, Y. L.
    Jiang, X. M.
    He, L. J.