Off-design performance analysis of organic Rankine cycle using real operation data from a heat source plant

被引:39
作者
Kim, In Seop [1 ]
Kim, Tong Seop [2 ]
Lee, Jong Jun [3 ]
机构
[1] Inha Univ, Grad Sch, Incheon, South Korea
[2] Inha Univ, Dept Mech Engn, Incheon 402751, South Korea
[3] Korea Dist Heating Corp, Seoul, South Korea
关键词
Organic Rankine cycle (ORC); Performance analysis; Off-design modeling; Power output; Heat source; Combined cycle cogeneration plant; ORC POWER-PLANT; THERMODYNAMIC ANALYSIS; GAS-TURBINE;
D O I
10.1016/j.enconman.2016.12.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
There has been increasing demand for cogeneration power plants, which provides high energy utilization. Research on upgrading power plant performance is also being actively pursued. The organic Rankine cycle (ORC) can operate with mid- and low-temperature heat sources and is suitable for enhancing performance of existing power plants. In this study, an off-design analysis model for the ORC was developed, which is driven by waste heat or residual heat from a combined cycle cogeneration plant. The applied heat sources are the exhaust gas from the heat recovery steam generator (Case 1) and waste heat from a heat storage unit (Case 2). Optimal design points of the ORC were selected based on the design heat source condition of each case. Then, the available ORC power output for each case was predicted using actual long-term plant operation data and a validated off-design analysis model. The ORC capacity of Case 2 was almost two times larger than that of Case 1. The predicted average electricity generation of both cases was less than the design output. The results of this paper reveal the importance of both the prediction of electricity generation using actual plant operation data and the need for optimal ORC system sizing. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:284 / 291
页数:8
相关论文
共 23 条
[1]  
Aspen Technology, 1995, HYSYS VER 7 3
[2]  
Beith R, 2011, WOODHEAD PUBL SER EN, P1
[3]  
Bejan A., 1993, HEAT TRANSFER
[4]   ORC power plant for electricity production from forest and agriculture biomass [J].
Borsukiewicz-Gozdur, A. ;
Wisniewski, S. ;
Mocarski, S. ;
Bankowski, M. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 87 :1180-1185
[5]   Thermoeconomic analysis and off-design performance of an organic Rankine cycle powered by medium-temperature heat sources [J].
Calise, Francesco ;
Capuozzo, Claudio ;
Carotenuto, Alberto ;
Vanoli, Laura .
SOLAR ENERGY, 2014, 103 :595-609
[6]  
Calm J.M., 2007, HPAC Eng (Heat Pip Air Cond), P50
[7]  
Cooke D., 1983, EN INC PEPSE US GROU
[8]   ON PREDICTION OF OFF-DESIGN MULTISTAGE TURBINE PRESSURES BY STODOLA ELLIPSE [J].
COOKE, DH .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1985, 107 (03) :596-606
[9]   An innovative ORC power plant layout for heat and power generation from medium- to low-temperature geothermal resources [J].
Fiaschi, Daniele ;
Lifshitz, Adi ;
Manfrida, Giampaolo ;
Tempesti, Duccio .
ENERGY CONVERSION AND MANAGEMENT, 2014, 88 :883-893