Alarm Fatigue in the Intensive Care Unit: Relevance and Response Time

被引:2
作者
Andrade-Mendez, B. [1 ,2 ]
Arias-Torres, D. O. [3 ,4 ]
Gomez-Tovar, L. O. [5 ,6 ]
机构
[1] Univ Surcolombiana, Programa Enfermeria, Huila, Colombia
[2] Univ Surcolombiana, Ciencias Salud, Huila, Colombia
[3] Univ Fed Estado Rio de Janeiro, Rio De Janeiro, Brazil
[4] Univ Surcolombiana, Grp Invest Cuidar, Huila, Colombia
[5] Univ Surcolombian, Programa Enfermeria, Huila, Colombia
[6] Univ Surcolombian, Enfermeria, Huila, Colombia
来源
ENFERMERIA INTENSIVA | 2020年 / 31卷 / 03期
关键词
Alert Fatigue Health Personnel; Clinical Alarms; Critical Care; Physiological monitoring; PATIENT; SAFETY;
D O I
10.1016/j.enfi.2019.11.007
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To establish the presence of alarm fatigue, the clinical relevance of alarms and the stimulus-response time of the health team in an Adult Intensive Care Unit. Method: Descriptive, quantitative, observational study, developed in the Multipurpose Adult Intensive Care Unit. Population made up of health personnel and the ICU teams. The method used was non-participant observation. Follow-up was carried out over 120 hours in three months. The variables studied were number of alarms activated, time elapsed between the alert sound of the blood pressure parameter, heart rate and oximetry and the response of the health personnel who attended the alarm. A descriptive statistical analysis was carried out. Results: 5,147 alarms were detected, on average 43 alarms / hour, of these 52.8% corresponded to multiparameter monitors and the rest to other equipment. Of those generated by multiparameter monitors, 37.3% were blood pressure, 33.4% oximetry and 29.3% heart rate. The clinical relevance was low in 42.7%, medium in 49.8% and high in 7.5%. The stimulus response time was between 0 and 60 seconds for 37% of the alarms; however, 42.5% had no response, which is why they are considered fatigued. A statistically significant relationship was found between the response time and the clinical relevance of the alarms (p=.000). Conclusions: The presence of alarm fatigue was evident; with predominance of clinical relevance in the middle and low ranges. The health personnel responded within the time established for timely attention to the non-fatigued alarms. (C) 2020 Sociedad Espanola de Enfermeria Intensiva y Unidades Coronarias (SEEIUC). Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 25 条
  • [1] Aguilar C, 2017, MED CRIT, V81, P171
  • [2] American Heart Association, 2015, ASP DEST ACT GUIAS A, V123, P34
  • [3] Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system
    Ancker, Jessica S.
    Edwards, Alison
    Nosal, Sarah
    Hauser, Diane
    Mauer, Elizabeth
    Kaushal, Rainu
    [J]. BMC MEDICAL INFORMATICS AND DECISION MAKING, 2017, 17
  • [4] FATIGUE ALARMS IN INTENSIVE CARE: DESCRIBING THE PHENOMENON THROUGH INTEGRATIVE LITERATURE REVIEW
    Bridi, Adriana Carla
    Lyra da Silva, Roberto Carlos
    Monteiro, Jorge Leandro do S.
    [J]. REVISTA DE PESQUISA-CUIDADO E FUNDAMENTAL ONLINE, 2013, 5 (03): : 27 - 41
  • [5] Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients
    Bridi, Adriana Carla
    Louro, Thiago Quinellato
    Lyra da Silva, Roberto Carlos
    [J]. REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2014, 22 (06): : 1034 - 1040
  • [6] Alarm fatigue and the implications for patient safety
    Carcereri de Oliveira, Adriana Elisa
    Machado, Adrielle Barbosa
    dos Santos, Edson Duque
    de Almeida, Erika Bicalho
    [J]. REVISTA BRASILEIRA DE ENFERMAGEM, 2018, 71 (06) : 3035 - 3040
  • [7] Alarm setting for the critically ill patient: A descriptive pilot survey of nurses' perceptions of current practice in an Australian Regional Critical Care Unit
    Christensen, Martin
    Dodds, Andrew
    Sauer, Josh
    Watts, Nigel
    [J]. INTENSIVE AND CRITICAL CARE NURSING, 2014, 30 (04) : 204 - 210
  • [8] Cvach M., 2017, BIOMED INSTRUM TECHN, V46, P268, DOI [10.2345/0899-8205-46.4.268?url_ver=Z39.88-2003Etrfrid=ori:rid:crossref.orgEtrfr_dat=cr_pub'/o3Dpubmed, DOI 10.2345/0899-8205-46.4.268?URL_VER=Z39.88-2003ETRFRID=ORI:RID:CROSSREF.ORGETRFR_DAT=CR_PUB'/O3DPUBMED]
  • [9] Devices H, 2014, TOP 10 HLTH TECHNOLO
  • [10] Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients
    Drew, Barbara J.
    Harris, Patricia
    Zegre-Hemsey, Jessica K.
    Mammone, Tina
    Schindler, Daniel
    Salas-Boni, Rebeca
    Bai, Yong
    Tinoco, Adelita
    Ding, Quan
    Hu, Xiao
    [J]. PLOS ONE, 2014, 9 (10):