摘要
Rational and Objectives: Computed tomography (CT) is the clinical gold-standard for high-resolution 3D visualization of cortical bone structures. However, ionizing radiation is of concern, particularly for pediatric patients. This study evaluates the feasibility of producing 3D human skull renderings using a novel bone-selective magnetic resonance imaging technique. Materials and Methods: A dual-radiofrequency pulse, dual-echo, 3D ultrashort echo time sequence was applied for scanning of a cadaver skull and five healthy adult subjects. Scans were each completed within 6 minutes. Semiautomatic segmentation of bone voxels was performed using ITK-SNAP software, leading to 3D renderings of the skulls. For comparison, thin-slice head CT scans were performed. Mimics software was used to measure eight anatomic distances from 3D renderings. Lin's Concordance Correlation test was applied to assess agreement between measurements from MR-based and CT-based 3D skull renderings. Results: The 3D rendered MR images depict most craniofacial features (e.g., zygomatic arch), although some voxels were erroneously included or excluded in the renderings. MR-based measurements differed from CT-based measurements by mean percent difference ranging from 2.3%-5.0%. Lin's Concordance Correlation Coefficients for MR-based vs CT-based measurements ranged from 0.998-1.000. Conclusion: The proposed dual-radiofrequency dual-echo 3D ultrashort echo time imaging technique produces high-resolution bonespecific images within a clinically feasible imaging time, leading to clear visualization of craniofacial skeletal structures. Concordance coefficients suggest good reliability of the method compared to CT. The method is currently limited by time and manual input necessary for segmentation correction. Further investigation is needed for more accurate 3D renderings and for scanning of pediatric patients.
引用
收藏
页码:1515 / 1522
页数:8
相关论文
共 50 条
  • [1] Cranial bone imaging using ultrashort echo-time bone-selective MRI as an alternative to gradient-echo based "black-bone" techniques
    Kamona, Nada
    Jones, Brandon C.
    Lee, Hyunyeol
    Song, Hee Kwon
    Rajapakse, Chamith S.
    Wagner, Connor S.
    Bartlett, Scott P.
    Wehrli, Felix W.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (01) : 83 - 92
  • [2] Cranial bone imaging using ultrashort echo-time bone-selective MRI as an alternative to gradient-echo based “black-bone” techniques
    Nada Kamona
    Brandon C. Jones
    Hyunyeol Lee
    Hee Kwon Song
    Chamith S. Rajapakse
    Connor S. Wagner
    Scott P. Bartlett
    Felix W. Wehrli
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2024, 37 : 83 - 92
  • [3] Craniofacial Imaging of Pediatric Patients by Ultrashort Echo-Time Bone- Selective MRI in Comparison to CT
    Kamona, Nada
    Ng, Jinggang J.
    Kim, Yohan
    Vu, Brian-Tinh D.
    Vossough, Arastoo
    Wagner, Connor S.
    Cordray, Holly
    Lee, Hyunyeol
    Villavisanis, Dillan F.
    Rajapakse, Chamith S.
    Bartlett, Scott P.
    Wehrli, Felix W.
    ACADEMIC RADIOLOGY, 2024, 31 (11) : 4629 - 4642
  • [4] Three contrasts in 3 min: Rapid, high-resolution, and bone-selective UTE MRI for craniofacial imaging with automated deep-learning skull segmentation
    Vu, Brian-Tinh Duc
    Kamona, Nada
    Kim, Yohan
    Ng, Jinggang J.
    Jones, Brandon C.
    Wehrli, Felix W.
    Song, Hee Kwon
    Bartlett, Scott P.
    Lee, Hyunyeol
    Rajapakse, Chamith S.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (01) : 245 - 260
  • [5] Zero TE MRI for Craniofacial Bone Imaging
    Lu, A.
    Gorny, K. R.
    Ho, M-L
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (09) : 1562 - 1566
  • [6] “Black Bone” MRI: a potential alternative to CT with three-dimensional reconstruction of the craniofacial skeleton in the diagnosis of craniosynostosis
    Karen A. Eley
    Stephen R. Watt-Smith
    Fintan Sheerin
    Stephen J. Golding
    European Radiology, 2014, 24 : 2417 - 2426
  • [7] "Black Bone" MRI: a potential alternative to CT with three-dimensional reconstruction of the craniofacial skeleton in the diagnosis of craniosynostosis
    Eley, Karen A.
    Watt-Smith, Stephen R.
    Sheerin, Fintan
    Golding, Stephen J.
    EUROPEAN RADIOLOGY, 2014, 24 (10) : 2417 - 2426
  • [8] Cadherin-11 enhances bone-selective metastasis of breast cancer
    Tamura, D
    Hiraga, T
    Myoui, A
    Yoshikawa, H
    Yoneda, T
    CANCER TREATMENT REVIEWS, 2005, 31 : S42 - S43
  • [9] CT imaging of craniofacial malformations
    Caruso, PA
    Harris, GJ
    Padwa, BL
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2003, 13 (03) : 541 - +
  • [10] "Black bone" MRI: a partial flip angle technique for radiation reduction in craniofacial imaging
    Eley, K. A.
    Mcintyre, A. G.
    Watt-Smith, S. R.
    Golding, S. J.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1011): : 272 - 278