Optimization of backwash parameters for hollow fiber membrane filters used for water purification

被引:8
|
作者
Sangrola, Shubham [1 ]
Kumar, Avinash [1 ]
Nivedhitha, S. [2 ]
Chatterjee, Jaideep [3 ]
Subbiah, Senthilmurugan [1 ]
Narayanasamy, Selvaraju [4 ]
机构
[1] Indian Inst Technol Guwahati, Chem Engn Dept, Gauhati, Assam, India
[2] Indian Inst Technol Guwahati, Ctr Environm, Gauhati, Assam, India
[3] BITS Pilani, Dept Chem Engn, Hyderabad Campus, Hyderabad 500078, Telangana, India
[4] Indian Inst Technol Guwahati, Dept Biosci & Bioengn, Gauhati, Assam, India
关键词
hollow fiber membrane; membrane backwash; membrane life; physical cleaning technique; ultrafiltration membrane; PACKING DENSITY; ULTRAFILTRATION; MODEL; IMPACT; MODULE;
D O I
10.2166/aqua.2020.079
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Membrane backwash is one of the most widely used membrane regeneration techniques in large-scale desalination operations and water and wastewater treatment applications. It is necessary in order to enhance membrane life and is critical in managing the cost of pure water. The estimation of optimal backwash conditions is very important for improved hollow fiber membrane (HFM) operations. A unique feature in HFM backwash operations is the lumen side pressure drop, which leads to variation in backwash water flow across the fiber length. In this work, the effect of fiber diameter, membrane structural properties and backwash water pressure and temperature on flow distribution across the membrane length is studied for HFM modules. An analytical model for HFM backwash is developed, and model predictions are compared with measured backwash water flow variation over the fiber length. Experimental results show that the backwash flow variation over the fiber length is minimized by maintaining low backwash water pressure. Simultaneously, minimum backwash flux for effective cleaning may be achieved by increasing backwash water temperature. Homogeneous flow distribution during backwash improves backwash efficiency or forward flow rejuvenation, which can also be achieved by optimizing fiber diameter and membrane permeability. The validated mathematical model may be used for the optimization of backwash operating conditions and HF dimensions to achieve homogeneous backwash flow distribution across the membrane length.
引用
收藏
页码:523 / 537
页数:15
相关论文
共 50 条
  • [1] Purification of lake water using a PES hollow fiber membrane
    Carolyn, K. M. W.
    Junaidi, M. U. M.
    Hashim, N. A.
    Hussain, M. A.
    Zuki, F. Mohamed
    Jan, B. Mohamed
    Nasir, N. A. Abdul
    Ahmad, A. L.
    WATER SUPPLY, 2020, 20 (02) : 529 - 537
  • [2] Tensile deformation of polytetrafluoroethylene hollow fiber membranes used for water purification
    Yonezu, Akio
    Iio, Shouichi
    Itonaga, Takehiro
    Yamamura, Hiroshi
    Chen, Xi
    WATER SCIENCE AND TECHNOLOGY, 2014, 70 (07) : 1244 - 1250
  • [3] Advanced Fouling Resistant PVDF Hollow Fiber Membrane for Water Purification
    Hanakawa, Masayuki
    Minegishi, Shin-Ichi
    SEN-I GAKKAISHI, 2009, 65 (03) : P92 - P96
  • [4] Preparation and characterization of glass hollow fiber membrane for water purification applications
    Siti Nurfatin Nadhirah Mohd Makhtar
    Mukhlis A. Rahman
    Ahmad Fauzi Ismail
    Mohd Hafiz Dzarfan Othman
    Juhana Jaafar
    Environmental Science and Pollution Research, 2017, 24 : 15918 - 15928
  • [5] Preparation and characterization of glass hollow fiber membrane for water purification applications
    Makhtar, Siti Nurfatin Nadhirah Mohd
    Rahman, Mukhlis A.
    Ismail, Ahmad Fauzi
    Othman, Mohd Hafiz Dzarfan
    Jaafar, Juhana
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (19) : 15918 - 15928
  • [6] Fouling in hollow fiber membrane microfilters used for household water treatment
    Murray, Anna
    Goeb, Mario
    Stewart, Barbara
    Hopper, Catherine
    Peck, Jamin
    Meub, Carolyn
    Asatekin, Ayse
    Lantagne, Daniele
    JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2015, 5 (02) : 220 - 228
  • [7] Online Backwash Optimization of Membrane Filtration for Produced Water Treatment
    Jepsen, Kasper L.
    Bram, Mads, V
    Hansen, Leif
    Yang, Zhenyu
    Lauridsen, Steven M. O.
    MEMBRANES, 2019, 9 (06)
  • [8] Giardia and Cryptosporidium in backwash water from rapid sand filters used for drinking water production
    Karanis, P
    Schoenen, D
    Seitz, HM
    ZENTRALBLATT FUR BAKTERIOLOGIE-INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY VIROLOGY PARASITOLOGY AND INFECTIOUS DISEASES, 1996, 284 (01): : 107 - 114
  • [9] DEVELOPMENT OF NEW HOLLOW FIBER MEMBRANE MACROMOLECULAR FILTERS
    KAYASHIMA, K
    SUEOKA, A
    SMITH, JW
    MATSUBARA, S
    ABE, Y
    UENO, M
    SHINAGAWA, S
    KATSUME, C
    MALCHESKY, PS
    NOSE, Y
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 66 - 70
  • [10] Laboratory Efficacy of Locally Available Backwashing Methods at Removing Fouling in Hollow-Fiber Membrane Filters Used for Household Water Treatment
    Heylen, Camille
    Oliveira Aguiar, Alice
    String, Gabrielle
    Domini, Marta
    Goff, Nathaniel
    Murray, Anna
    Asatekin, Ayse
    Lantagne, Daniele
    MEMBRANES, 2021, 11 (05)