Influence of Magnet Imperfections on Torque Pulsation of PM Machines Having Different Pole and Slot Combinations

被引:0
|
作者
Palani, D. [1 ]
Azar, Z. [2 ]
Thomas, A. [2 ]
Zhu, Z. Q. [1 ]
Gladwin, D. [1 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 31D, S Yorkshire, England
[2] Sheffield Siemens Wind Power Res Ctr, Sheffield S3 7HQ, S Yorkshire, England
来源
2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM) | 2016年
关键词
Cogging torque; Finite element method; Magnet imperfections; Permanent magnet (PM); Torque ripple; COGGING TORQUE; INDUCED VIBRATION; MOTORS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the influence of magnet imperfections on the torque pulsation of permanent magnet machines having different pole/slot combinations (2p/Ns), including fractional-slot as well as integer-slot topologies. The magnet imperfections result in changing in the cogging period, which in turn might reduce the effectiveness of skewing, and also introduce new harmonic orders that could lead to more noise and vibrations. It is found that such influence is reduced significantly with the number of structure cyclic symmetry, which is equal to the greatest common divisor between the pole and slot numbers. Hence, the imperfection is more severe in machines having similar numbers of poles and slots, i.e. 2p=N-s +/- 1 followed by 2p=N-s +/- 2, and the influence is relatively smaller in other fractional slot combinations as well as integral-slot machines.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 50 条
  • [21] Influence of stator slot openings on losses and torque in axial flux permanent magnet machines
    Sergeant, Peter
    Vansompel, Hendrik
    Dupre, Luc
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2016, 130 : 22 - 31
  • [22] Influence of Slot and Pole Number Combinations on Voltage Distortion in Surface-Mounted Permanent Magnet Machines With Local Magnetic Saturation
    Wu, D.
    Zhu, Z. Q.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (04) : 1460 - 1471
  • [23] Influence of Slot Openings and Tooth Profile on Cogging Torque in Axial-Flux PM Machines
    Wanjiku, J.
    Khan, M. A.
    Barendse, P. S.
    Pillay, P.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (12) : 7578 - 7589
  • [24] Comparative Study of NVH of Permanent Magnet Machines According to Rotor Eccentricity With Fractional Pole/Slot Combinations
    Bang, Tae-Kyoung
    Shin, Kyung-Hun
    Lee, Young-Geun
    Lee, Jeong-In
    Lee, Hoon-Ki
    Cho, Han-Wook
    Choi, Jang-Young
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (06)
  • [25] Effect of Pole Shaping on Torque Characteristics of Consequent Pole PM Machines
    Qi, J.
    Zhu, Z. Q.
    Yan, L.
    Jewell, G. W.
    Gan, C. W.
    Ren, Y.
    Brockway, S.
    Hilton, C.
    2021 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2021,
  • [26] Effect of Pole Shaping on Torque Characteristics of Consequent Pole PM Machines
    Qi, Ji
    Zhu, Zi-Qiang
    Yan, Luocheng
    Jewell, Geraint Wyn
    Gan, Chengwei
    Ren, Yuan
    Brockway, Simon
    Hilton, Chris
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (03) : 3511 - 3521
  • [27] Expansion of the Feasible Slot/Pole Combinations in the Fractional Slot PM Machines by Applying Three-Slot Pitch Coils
    Jalali, Pezhman
    Boroujeni, Samad Taghipour
    Khoshtarash, Javad
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (02) : 993 - 999
  • [28] Torque Ripple Minimization Technique in Fractional-Slot PM Brushless Machines
    Zolkapli, Z. Z.
    Jamil, M. L. Mohd
    Al-Habshi, S. M.
    Jidin, A.
    Othman, M. N.
    2014 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2014, : 117 - 121
  • [29] Comparison of Axial Flux Permanent Magnet Machines with Fractional and Integral Slot per Pole
    Nguyen, T. D.
    Tseng, K. J.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [30] Influence of design parameters on cogging torque in permanent magnet machines
    Zhu, ZQ
    Howe, D
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (04) : 407 - 412