New mode for measuring axial length with an optical low-coherence reflectometer in eyes with dense cataract

被引:13
|
作者
Shammas, H. John [1 ,2 ]
Wetterwald, Nicolas [4 ]
Potvin, Richard [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
[2] Shammas Eye Med Ctr, Lynwood, CA USA
[3] Sci Vis, Akron, NY 14001 USA
[4] Augenarztpraxis EYEC, Bern, Switzerland
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2015年 / 41卷 / 07期
关键词
INTRAOCULAR-LENS POWER; BIOMETRY; SURGERY;
D O I
10.1016/j.jcrs.2014.10.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate a new algorithm for measuring eyes with dense cataract using a biometer based on optical low-coherence reflectometry (OLCR). SETTING: Shammas Eye Medical Center, Lynwood, California, USA, and Augenarztpraxis EYEC, Bern, Switzerland. DESIGN: Cross-sectional retrospective study. METHODS: Data were collected from 2 sites where the new Dense Cataract Measurement mode for the OLCR optical biometer (Lenstar LS 900) had been implemented. Related ultrasound (US) data for patients whose eyes could not be measured with optical biometry were also collected where available. The percentage of eyes that were measurable in the new mode that were not measurable in the standard mode was calculated. The quality of the measurements by the new mode was evaluated using postoperative axial length measurements and/or concurrent US measurements, where available. RESULTS: Data for 4791 eyes were available for analysis. Axial length measurement was possible using the standard algorithm in 94.4% of cases. The use of the new mode allowed for measurement of an additional 4.0% of cases, a statistically significant increase (P<.001). Comparisons of AL measurements with concurrent US or postoperative optical biometry showed high correlations, with the 95% limits of agreement of -0.47 to +0.29 mm, similar to results for standard measurements. CONCLUSIONS: The new measurement mode of the OLCR system provided a significant increase in the number of eyes that could be measured with optical biometry. Axial length measurements using the new mode appeared as reliable as those made using the standard measurement mode.
引用
收藏
页码:1365 / 1369
页数:5
相关论文
共 50 条
  • [1] Optical low-coherence reflectometer for measuring WDM components
    NTT Opto-Electronics Laboratories, Tokai, Ibaraki-ken 319-1193, Japan
    不详
    IEEE Photonics Technol Lett, 7 (857-859):
  • [2] Optical low-coherence reflectometer for measuring WDM components
    Mechels, S
    Takada, K
    Okamoto, K
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1999, 11 (07) : 857 - 859
  • [3] Accuracy and feasibility of axial length measurements by a new optical low-coherence reflectometry-based device in eyes with posterior subcapsular cataract
    Einan-Lifshitz, Adi
    Rozenberg, Assaf
    Wang, Li
    Koch, Douglas D.
    Shoshany, Nadav
    Zadok, David
    Avni, Isaac
    Abulafia, Adi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07): : 898 - 901
  • [4] DESIGN OF A PRECISION OPTICAL LOW-COHERENCE REFLECTOMETER
    BOOSTER, DH
    CHOU, H
    HART, MG
    MIFSUD, SJ
    RAWSON, RF
    HEWLETT-PACKARD JOURNAL, 1993, 44 (01): : 39 - &
  • [5] Optical low-coherence reflectometer for differential phase measurement
    Davé, DP
    Milner, TE
    OPTICS LETTERS, 2000, 25 (04) : 227 - 229
  • [6] Repeatability and reproducibility of optical biometry implemented in a new optical coherence tomographer and comparison with a optical low-coherence reflectometer
    Kanclerz, Piotr
    Hoffer, Kenneth J.
    Rozema, Jos J.
    Przewlocka, Katarzyna
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11): : 1619 - 1624
  • [7] Reproducibility of ocular biometry with a new noncontact optical low-coherence reflectometer in children
    Sahin, Afsun
    Gursoy, Huseyin
    Basmak, Hikmet
    Yildirim, Nilgun
    Usalp, Zuhat
    Colak, Ertugrul
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 194 - 198
  • [8] Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer
    Mirjana Bjeloš Rončević
    Mladen Bušić
    Ivan Čima
    Biljana Kuzmanović Elabjer
    Damir Bosnar
    Daliborka Miletić
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 83 - 87
  • [9] Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer
    Roncevic, Mirjana Bjelos
    Busic, Mladen
    Cima, Ivan
    Elabjer, Biljana Kuzmanovic
    Bosnar, Damir
    Miletic, Daliborka
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (01) : 83 - 87
  • [10] Comparison and Evaluation of Ocular Biometry Using a New Noncontact Optical Low-Coherence Reflectometer
    Rohrer, Kaspar
    Frueh, Beatrice E.
    Waelti, Rudolf
    Clemetson, Isabelle A.
    Tappeiner, Christoph
    Goldblum, David
    OPHTHALMOLOGY, 2009, 116 (11) : 2087 - 2092