Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system

被引:152
作者
Widera, G [1 ]
Johnson, J [1 ]
Kim, L [1 ]
Libiran, L [1 ]
Nyam, K [1 ]
Daddona, PE [1 ]
Cormier, M [1 ]
机构
[1] ALZA Corp, Physiol Syst, Mountain View, CA 94039 USA
关键词
ovalbumin; immunization; microneedle array; intracutaneous;
D O I
10.1016/j.vaccine.2005.09.049
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
immunization to the model antigen ovalbumin was investigated using a novel intracutaneous delivery system consisting of antigen-coated microneedle arrays. The influence of the following parameters on the resulting immune responses was investigated: depth of vaccine delivery, dose of vaccine delivered, density of microneedles on the array, and area of application. The immune response was found to be dose dependent, and mostly independent of depth of delivery, density of microneedles, or area of application. Our studies show that the shortest, most tolerable microneedle arrays can be used for achieving consistent and high antibody titers. Overall, the microneedle array proves to be a very versatile delivery technology, allowing easy and reproducible antigen delivery to skin for efficient vaccination without the use of a needle and syringe. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1653 / 1664
页数:12
相关论文
共 32 条
  • [1] AMERI M, Patent No. 20050106209
  • [2] BOSS JD, 1981, SKIN IMMUNE SYSTEM C
  • [3] Bouloc A, 1999, EUR J IMMUNOL, V29, P446, DOI 10.1002/(SICI)1521-4141(199902)29:02<446::AID-IMMU446>3.0.CO
  • [4] 2-A
  • [5] A DOSE-RELATED CURVE OF WOUND TENSILE-STRENGTH FOLLOWING ULTRAVIOLET-IRRADIATION IN THE HAIRLESS GUINEA-PIG
    BRANTLEY, SK
    DAVIDSON, SF
    DAS, SK
    [J]. AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1991, 302 (02) : 75 - 81
  • [6] Accurate DS-CDMA bit-error probability calculation in Rayleigh fading
    Cheng, J
    Beaulieu, NC
    [J]. IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2002, 1 (01) : 3 - 15
  • [7] Transdermal delivery of desmopressin using a coated microneedle array patch system
    Cormier, M
    Johnson, B
    Ameri, M
    Nyam, K
    Libiran, L
    Zhang, DD
    Daddona, P
    [J]. JOURNAL OF CONTROLLED RELEASE, 2004, 97 (03) : 503 - 511
  • [8] CORMIER M, 2003, Patent No. 0914178
  • [9] Cormier M., 2002, MACROFLUX TECHNOLOGY, P589, DOI [10.1201/9780203910337.ch48, DOI 10.1201/9780203910337.CH48]
  • [10] SKIN, A FIRST LEVEL LYMPHOID ORGAN
    FICHTELIUS, KE
    GROTH, O
    LIDEN, S
    [J]. INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1970, 37 (06): : 607 - +