Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses

被引:121
|
作者
Auerbach, Edward J. [1 ]
Xu, Junqian [1 ]
Yacoub, Essa [1 ]
Moeller, Steen [1 ]
Ugurbil, Kamil [1 ]
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
parallel imaging; multiband; simultaneous multislice; diffusion; fMRI; WHOLE-BRAIN; FMRI; MRI; COLUMNS;
D O I
10.1002/mrm.24719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate an alternative method for generating multibanded radiofrequency (RF) pulses for use in multiband slice-accelerated imaging with slice-GRAPPA unaliasing, substantially reducing the required peak power without bandwidth compromises. This allows much higher accelerations for spin-echo methods such as SE-fMRI and diffusion-weighted MRI where multibanded slice acceleration has been limited by available peak power. Theory and Methods: Multibanded time-shifted RF pulses were generated by inserting temporal shifts between the applications of RF energy for individual bands, avoiding worst-case constructive interferences. Slice profiles and images in phantoms and human subjects were acquired at 3 T. Results: For typical sinc pulses, time-shifted multibanded RF pulses were generated with little increase in required peak power compared to single-banded pulses. Slice profile quality was improved by allowing for higher pulse bandwidths, and image quality was improved by allowing for optimum flip angles to be achieved. Conclusion: A simple approach has been demonstrated that significantly alleviates the restrictions imposed on achievable slice acceleration factors in multiband spin-echo imaging due to the power requirements of multibanded RF pulses. This solution will allow for increased accelerations in diffusion-weighted MRI applications where data acquisition times are normally very long and the ability to accelerate is extremely valuable. Magn Reson Med 69:12611267, 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1261 / 1267
页数:7
相关论文
共 13 条
  • [1] Vessel architecture imaging using multiband gradient-echo/spin-echo EPI
    Zhang, Ke
    Yun, Seong Dae
    Triphan, Simon M. F.
    Sturm, Volker J.
    Buschle, Lukas R.
    Hahn, Artur
    Heiland, Sabine
    Bendszus, Martin
    Schlemmer, Heinz-Peter
    Shah, N. Jon
    Ziener, Christian H.
    Kurz, Felix T.
    PLOS ONE, 2019, 14 (08):
  • [2] Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
    Boujraf, Said
    Summers, Paul
    Belahsen, Faouzi
    Pruessmann, Klaas
    Kollias, Spyros
    JOURNAL OF MEDICAL PHYSICS, 2009, 34 (01) : 37 - 42
  • [3] Accelerated spin-echo functional MRI using multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider) simultaneous multislice echo-planar imaging
    Han, SoHyun
    Liao, Congyu
    Manhard, Mary Kate
    Park, Daniel Joseph
    Bilgic, Berkin
    Fair, Merlin J.
    Wang, Fuyixue
    Blazejewska, Anna, I
    Grissom, William A.
    Polimeni, Jonathan R.
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 206 - 220
  • [4] Susceptibility Compensated fMRI Study Using a Tailored RF Echo Planar Imaging Sequence
    Chung, Jun-Young
    Yoon, Hyo Woon
    Kim, Young-Bo
    Park, Hyun Wook
    Cho, Zang-Hee
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) : 221 - 228
  • [5] Accelerated whole-brain perfusion imaging using a simultaneous multislice spin-echo and gradient-echo sequence with joint virtual coil reconstruction
    Manhard, Mary Kate
    Bilgic, Berkin
    Liao, Congyu
    Han, SoHyun
    Witzel, Thomas
    Yen, Yi-Fen
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 973 - 983
  • [6] MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears
    Kowalchuk, RM
    Kneeland, JB
    Dalinka, MK
    Siegelman, ES
    Dockery, WD
    SKELETAL RADIOLOGY, 2000, 29 (09) : 520 - 524
  • [7] SNR-efficient distortion-free diffusion relaxometry imaging using accelerated echo-train shifted echo-planar time-resolving imaging (ACE-EPTI)
    Dong, Zijing
    Wang, Fuyixue
    Wald, Lawrence
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) : 164 - 179
  • [8] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Takatsu, Yasuo
    Yamamura, Kenichiro
    Yamatani, Yuya
    Takahashi, Daisuke
    Yoshida, Rei
    Asahara, Masaki
    Honda, Michitaka
    Miyati, Tosiaki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 89 - 99
  • [9] Small field of view imaging using wavelet encoding with 2 dimensional RF pulses and gradient echo: phantom results
    Serrai, Hacene
    Young, Richard
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2010, 23 (01) : 45 - 52
  • [10] Diffusion Tensor Echo Planar Imaging Using Surface Coil Transceiver with a Semiadiabatic RF Pulse Sequence at 14.1T
    van de Looij, Yohan
    Kunz, Nicolas
    Hueppi, Petra
    Gruetter, Rolf
    Sizonenko, Stephane
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) : 732 - 737