Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging

被引:94
作者
Betgen, Anja [1 ]
Alderliesten, Tanja [1 ]
Sonke, Jan-Jakob [1 ]
van Vliet-Vroegindeweij, Corine [1 ]
Bartelink, Harry [1 ]
Remeijer, Peter [1 ]
机构
[1] Antoni van Leeuwenhoek Hosp, Dept Radiat Oncol, Netherlands Canc Inst, NL-1066 CX Amsterdam, Netherlands
关键词
IGRT; Breast cancer; Geometrical uncertainties; Breath hold; Surface imaging; RADIATION-THERAPY; ADAPTED RADIOTHERAPY; SYSTEM; REPRODUCIBILITY; REGISTRATION; HEART; IRRADIATION; REDUCTION; ALIGNMENT; ACCURACY;
D O I
10.1016/j.radonc.2012.12.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify set-up uncertainties during voluntary deep inspiration breath hold (DIBH) radiotherapy using 3D-surface imaging in patients with left sided breast cancer. Material and methods: Nineteen patients were included. Cone-beam CT-scan (CBCT) was used for online set-up correction while patients were instructed to perform a voluntary DIBH. The reproducibility of the DIBH during treatment was monitored with 2D-fluoroscopy and portal imaging. Simultaneously, a surface imaging system was used to capture 3D-surfaces throughout CBCT acquisition and delivery of treatment beams. Retrospectively, all captured surfaces were registered to the planning-CT surface. Interfraction, intra-fraction and intra-beam set-up variability were quantified in left-right, cranio-caudal and anterior-posterior direction. Results: Inter-fraction systematic (Sigma) and random (sigma) translational errors (1SD) before and after set-up correction were between 0.20-0.50 cm and 0.09-0.22 cm, respectively, whereas rotational Sigma and sigma errors were between 0.08 and 1.56 degrees. The intra-fraction Sigma and sigma errors were <= 0.14 cm and <= 0.47 degrees. The intra-beam SD variability was <= 0.08 cm and <= 0.28 degrees in all directions. Conclusion: Quantification of 3D set-up variability in DIBH RT showed that patients are able to perform a very stable and reproducible DIBH within a treatment fraction. However, relatively large inter-fraction variability requires online image guided set-up corrections. (C) 2013 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 106 (2013) 225-230
引用
收藏
页码:225 / 230
页数:6
相关论文
共 23 条
[1]  
Alderliesten T, SPIE 2012 P, V8316
[2]   Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy [J].
Alderliesten, Tanja ;
Sonke, Jan-Jakob ;
Betgen, Anja ;
Honnef, Joeri ;
van Vliet-Vroegindeweij, Corine ;
Remeijer, Peter .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02) :536-542
[3]   Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients [J].
Bert, C ;
Metheany, KG ;
Doppke, KP ;
Taghian, AG ;
Powell, SN ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04) :1265-1274
[4]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[5]   CLINICAL RESULTS OF IMAGE-GUIDED DEEP INSPIRATION BREATH HOLD BREAST IRRADIATION [J].
Borst, Gerben R. ;
Sonke, Jan-Jakob ;
den Hollander, Suzanne ;
Betgen, Anja ;
Remeijer, Peter ;
van Giersbergen, Aline ;
Russell, Nicola S. ;
Elkhuizen, Paula H. M. ;
Bartelink, Harry ;
van Vliet-Vroegindeweij, Corine .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05) :1345-1351
[6]   The use of an optical outlining system for weekly on-set verification of patients with carcinoma of the breast [J].
Casebow, MP ;
Harris, RL ;
Jarvis, RJ .
RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) :99-103
[7]   Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapy [J].
Cervino, Laura I. ;
Gupta, Sonia ;
Rose, Mary A. ;
Yashar, Catheryn ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22) :6853-6865
[8]   Long-term risk of cardiovascular disease in 10-year survivors of breast cancer [J].
Hooning, Maartje J. ;
Botma, Akke ;
Aleman, Berthe M. P. ;
Baaijens, Margreet H. A. ;
Bartelink, Harry ;
Klijn, Jan G. M. ;
Taylor, Carolyn W. ;
van Leeuvven, Flora E. .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2007, 99 (05) :365-375
[9]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[10]   Reduction of cardiac and pulmonary complication probabilities after breathing adapted radiotherapy for breast cancer [J].
Korreman, Stine S. ;
Pedersen, Anders N. ;
Aarup, Lasse Rye ;
Nottrup, Trine J. ;
Specht, Lena ;
Nystrom, Hakan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (05) :1375-1380