Levels and health risk assessments of particulate matters (PM2.5 and PM10) in indoor/outdoor air of waterpipe cafes in Tehran, Iran

被引:54
作者
Heydari, Gholamreza [1 ]
Taghizdeh, Farhad [2 ]
Fazlzadeh, Mehdi [3 ,4 ]
Jafari, Ahmad Jonidi [2 ,5 ]
Asadgol, Zahra [2 ]
Mehrizi, Ehsan Abouee [2 ,6 ]
Moradi, Masoud [7 ]
Arfaeinia, Hossein [8 ,9 ]
机构
[1] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis, Tobacco Prevent & Control Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[3] Ardabil Univ Med Sci, Social Determinants Hlth Res Ctr, Ardebil, Iran
[4] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[5] Iran Univ Med Sci, Res Ctr Environm Hlth Technol, Tehran, Iran
[6] Shahid Sadoughi Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Yazd, Iran
[7] Kermanshah Univ Med Sci, Res Ctr Environm Determinants Hlth, Kermanshah, Iran
[8] Bushehr Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Bushehr, Iran
[9] Bushehr Univ Med Sci, Persian Gulf Biomed Sci Res Inst, Syst Environm Hlth & Energy Res Ctr, Bushehr, Iran
关键词
Air quality; PM2.5; PM10; Waterpipe cafes; Risk assessment; Tehran; INDOOR AIR; SMOKING; BTEX; TOBACCO; PIPE;
D O I
10.1007/s11356-019-04202-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine the concentration of particulate matters (PM2.5 and PM10), 36 samples were collected from indoor/outdoor air of hookah cafes (HS), cigarette cafes (CS), both hookah and cigarette (HCS), and no-smoking building (NS) in Tehran City from December 2017 to March 2018. The mean +/- SD of PM10 concentration in the indoor air of the cafes in terms of HS, CS, HCS, and NS sites has been 702.35, 220.20, 1156.60, and 60.12g/m(3), while for PM2.5, the values have been 271.92, 111.80, 619.10, and 22.25g/m(3), respectively. It was also found that the PM concentration inside the cafes was higher during weekend session (with a higher number of active smokers), than during the weekday sessions. Moreover, the PM levels in the indoor air of the cafes were considerably higher than those of the outdoors (p<0.05). Based on path analysis, the number of active smokers had the highest influence on production of PM inside the cafes, followed by the tobacco type. Finally, the mean excess lifetime cancer risk (ELCR) for PM2.5 in the indoor air of cafes was observed in the range of 0.64x10(-5)-14.98x10(-5). Also, the mean of hazard quotient (HQ) for PM2.5 and PM10 was calculated in range of 0.82-18.4 and 0.16-3.28, respectively, which corresponds to an unacceptably high risk for human health. The PM levels in the indoor air of smoking cafes in Tehran are significantly high, such that it can cause serious risks for the health of both the customers and personnel. Thus, it is necessary that suitable controlling strategies be adopted for this public health threat.
引用
收藏
页码:7205 / 7215
页数:11
相关论文
共 50 条
  • [21] The Effect of Meteorological Conditions on PM10 and PM2.5 Pollution of the Air
    Radzka, Elzbieta
    Rymuza, Katarzyna
    ROCZNIK OCHRONA SRODOWISKA, 2019, 21 (01): : 611 - 628
  • [22] Residential indoor PM10 and PM2.5 in Hong kong and the elemental composition
    Chao, CY
    Wong, KK
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (02) : 265 - 277
  • [23] Levels of PM10 and PM2.5 in Taipei Rapid Transit System
    Cheng, Yu-Hsiang
    Lin, Yi-Lun
    Liu, Chia-Chen
    ATMOSPHERIC ENVIRONMENT, 2008, 42 (31) : 7242 - 7249
  • [24] Particulate matter less than 10 μm (PM10) and fine particles less than 2.5 μm (PM2.5):: relationships between indoor, outdoor and personal concentrations
    Monn, C
    Fuchs, A
    Hogger, D
    Junker, M
    Kogelschatz, D
    Roth, N
    Wanner, HU
    SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 208 (1-2) : 15 - 21
  • [25] Measurement of ambient particulate matter (PM1.0, PM2.5 and PM10) in Khulna City of Bangladesh and their implications for human health
    Saju, Jobaer Ahmed
    Bari, Quazi Hamidul
    Mohiuddin, Kazi A. B. M.
    Strezov, Vladimir
    ENVIRONMENTAL SYSTEMS RESEARCH, 2023, 12 (01)
  • [26] Characterization of short- and medium-chain chlorinated paraffins in outdoor/indoor PM10/PM2.5/PM1.0 in Beijing, China
    Huang, Huiting
    Gao, Lirong
    Xia, Dan
    Qiao, Lin
    Wang, Runhua
    Su, Guijin
    Liu, Wenbin
    Liu, Guorui
    Zheng, Minghui
    ENVIRONMENTAL POLLUTION, 2017, 225 : 674 - 680
  • [27] Distribution of PM2.5 and PM10-2.5 in PM10 fraction in ambient air due to vehicular pollution in Kolkata megacity
    Das, Manab
    Maiti, Subodh Kumar
    Mukhopadhyay, Ujjal
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2006, 122 (1-3) : 111 - 123
  • [28] Indoor and outdoor air quality analysis for the city of Nablus in Palestine: seasonal trends of PM10, PM5.0, PM2.5, and PM1.0 of residential homes
    Jodeh, S.
    Hasan, A. R.
    Amarah, J.
    Judeh, Father
    Salghi, R.
    Lgaz, H.
    Jodeh, W.
    AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (02) : 229 - 237
  • [29] Multivariate methods for indoor PM10 and PM2.5 modelling in naturally ventilated schools buildings
    Elbayoumi, Maher
    Ramli, Nor Azam
    Yusof, Noor Faizah Fitri Md
    Bin Yahaya, Ahmad Shukri
    Al Madhoun, Wesam
    Ul-Saufie, Ahmed Zia
    ATMOSPHERIC ENVIRONMENT, 2014, 94 : 11 - 21
  • [30] Statistical Evaluation of Risk Associated With Particulate Matter (PM2.5 and PM10) in Ondo State, Nigeria
    Ediagbonya, Thompson Faraday
    Francis, Sabastine Dekas
    Omotayo-Tomo, Modupe Stella
    Oziegbe, Friday Elumah
    Titiola, Claudius
    ENVIRONMENTAL QUALITY MANAGEMENT, 2025, 34 (04)