Basic research for development of the beam profile monitor based on a Faraday cup array system

被引:0
作者
Park, Mook-Kwang [1 ]
机构
[1] Korea Atom Energy Res Inst, Korea Multipurpose Accelerator Complex, Gyeongju 38180, South Korea
关键词
Beam profile; Faraday cup array; Multiplexer;
D O I
10.3938/jkps.67.1418
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The basic design used to develop a beam profile monitor based on a Faraday cup array (FCA), which has the advantages of high robustness, reliability, and long-term stability, along with the ability to measure the ion current over a wide dynamic range, was developed. The total system is divided into three parts: i.e., a faraday cup, measuring electronics, and a display program part. The FCA was considered to consist of a collimator, suppressor, insulator frame, and 64 (8 x 8 array) tiny Faraday cups (FC). An electronic circuit using a multiplexer was applied to effectively address many signal lines and the printed circuit board (PCB) was designed to be divided into three parts, i.e., an electrode PCB (ELEC PCB), capacitance PCB (CAP PCB), and control PCB (CON PCB).
引用
收藏
页码:1418 / 1421
页数:4
相关论文
共 4 条
[1]  
Darling RB, 2002, SENSOR ACTUAT A-PHYS, V95, P84, DOI 10.1016/S0924-4247(01)00718-X
[2]   Direct high-resolution ion beam-profile imaging using a position-sensitive Faraday cup array [J].
Panitzsch, Lauri ;
Stalder, Michael ;
Wimmer-Schweingruber, Robert F. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (11)
[3]   Development and first experimental tests of Faraday cup array [J].
Prokupek, J. ;
Kaufman, J. ;
Margarone, D. ;
Krus, M. ;
Velyhan, A. ;
Krasa, J. ;
Burris-Mog, T. ;
Busold, S. ;
Deppert, O. ;
Cowan, T. E. ;
Korn, G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01)
[4]   Faraday cup detector array with electronic multiplexing for multichannel mass spectrometry [J].
Scheidemann, AA ;
Darling, RB ;
Schumacher, FJ ;
Isakharov, A .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2002, 20 (03) :597-604