Effect of Device Design on the Aerosolization of a Carrier-Based Dry Powder Inhaler-a Case Study on AerolizerA® ForadileA®

被引:56
作者
Zhou, Qi Tony [1 ]
Tong, Zhenbo [2 ]
Tang, Patricia [1 ]
Citterio, Mauro [3 ]
Yang, Runyu [2 ]
Chan, Hak-Kim [1 ]
机构
[1] Univ Sydney, Fac Pharm, Adv Drug Delivery Grp, Sydney, NSW 2006, Australia
[2] Univ New S Wales, Sch Mat Sci & Engn, Sydney, NSW, Australia
[3] Plastiape SpA, R&D & Industrializat, I-23875 Osnago, Lecco, Italy
基金
澳大利亚研究理事会;
关键词
aerosolization; computational fluid dynamics; device design; discrete element method; dry powder inhalers; COMPUTATIONAL FLUID-DYNAMICS; IN-VITRO; PERFORMANCE; DELIVERY; DRUG; FLOW; FORMULATION; INHALATION; RESISTANCE; SYSTEMS;
D O I
10.1208/s12248-013-9458-6
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The objective of this study is to investigate the effect of device design of the Aerolizer(A (R)) on the aerosolization of a carrier-based dry powder inhaler formulation (Foradile(A (R))). The Aerolizer was modified by reducing the air inlet size and mouthpiece length to 1/3 of the original dimensions, or by increasing the grid voidage. Aerosolization of the powder formulation was assessed on a multi-stage liquid impinger at air flow rates of 30, 60, and 100 L/min. Coupled CFD-DEM simulations were performed to investigate the air flow pattern and particle impaction. There was no significant difference in the aerosolization behavior between the original and 1/3 mouthpiece length devices. Significant increases in FPF total and FPF emitted were demonstrated when the inlet size was reduced, and the results were explained by the increases in air velocity and turbulence from the CFD analysis. No significant differences were shown in FPF total and FPF emitted when the grid voidage was increased, but more drugs were found to deposit in induction port and to a lesser extent, the mouthpiece. This was supported by the CFD-DEM analysis which showed the particle-device collisions mainly occurred in the inhaler chamber, and the cross-grid design increased the particle-device collisions on both mouthpiece and induction port. The air inlet size and grid structure of the Aerolizer(A (R)) were found to impact significantly on the aerosolization of the carrier-based powder.
引用
收藏
页码:511 / 522
页数:12
相关论文
共 22 条
[1]   Calibration at different flow rates of a multistage liquid impinger [J].
Asking, L ;
Olsson, B .
AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (01) :39-49
[2]  
Chan HK, 2006, J AEROSOL MED, V19, P21, DOI 10.1089/jam.2006.19.21
[3]   In vitro aerosol performance and dose uniformity between the Foradile® Aerolizer® and the Oxis® Turbuhaler® [J].
Chew, NYK ;
Chan, HK .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (04) :495-501
[4]   CFD-DEM modelling of multiphase flow in dense medium cyclones [J].
Chu, K. W. ;
Wang, B. ;
Yu, A. B. ;
Vince, A. .
POWDER TECHNOLOGY, 2009, 193 (03) :235-247
[5]   THE RELATIONSHIP BETWEEN POWDER INHALER RESISTANCE AND PEAK INSPIRATORY CONDITIONS IN HEALTHY-VOLUNTEERS - IMPLICATIONS FOR IN-VITRO TESTING [J].
CLARK, AR ;
HOLLINGWORTH, AM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (02) :99-110
[6]   Influence of mouthpiece geometry on the aerosol delivery performance of a dry powder inhaler [J].
Coates, Matthew S. ;
Chan, Hak-Kim ;
Fletcher, David F. ;
Chiou, Herbert .
PHARMACEUTICAL RESEARCH, 2007, 24 (08) :1450-1456
[7]   Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 2: Air inlet size [J].
Coates, Matthew S. ;
Chan, Hak-Kim ;
Fletcher, David F. ;
Raper, Judy A. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 95 (06) :1382-1392
[8]   Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 1: Grid structure and mouthpiece length [J].
Coates, MS ;
Fletcher, DF ;
Chan, HK ;
Raper, JA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (11) :2863-2876
[9]   Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses [J].
Coates, MS ;
Chan, HK ;
Fletcher, DF ;
Raper, JA .
PHARMACEUTICAL RESEARCH, 2005, 22 (09) :1445-1453
[10]   A critical view on lactose-based drug formulation and device studies for dry powder inhalation: Which are relevant and what interactions to expect? [J].
de Boer, A. H. ;
Chan, H. K. ;
Price, R. .
ADVANCED DRUG DELIVERY REVIEWS, 2012, 64 (03) :257-274