Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor

被引:33
作者
Ang, Lee Fung [1 ]
Por, Lip Yee [2 ]
Yam, Mun Fei [1 ]
机构
[1] Univ Sains Malaysia, Sch Pharmaceut Sci, Minden, Penang, Malaysia
[2] Univ Malaya, Fac Comp Sci & Informat Technol, Kuala Lumpur, Malaysia
来源
PLOS ONE | 2013年 / 8卷 / 08期
关键词
HORSERADISH-PEROXIDASE; OXIDASE; ELECTRODE; SENSOR; FILMS; NANOPARTICLES;
D O I
10.1371/journal.pone.0070597
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra showed the existence of intermolecular interactions between chitosan and glucose oxidase (GOD). Higher catalytic activities were observed on for GOD-MMCHI than GOD-LMCHI and for those crosslinked with glutaraldehyde than using the adsorption technique. Enzyme loading greater than 0.6 mg decreased the activity. Under optimum conditions (pH 6.0, 35 degrees C and applied potential of 0.6 V) response times of 85 s and 65 s were observed for medium molecular weight chitosan glucose biosensor (GOD-MMCHI/PT) and low molecular weight chitosan glucose biosensor (GOD-LMCHI/PT), respectively. The apparent Michaelis-Menten constant (K-M(app)) was found to be 12.737 mM for GOD-MMCHI/PT and 17.692 mM for GOD-LMCHI/PT. This indicated that GOD-MMCHI/PT had greater affinity for the enzyme. Moreover, GOD-MMCHI/PT showed higher sensitivity (52.3666 nA/mM glucose) when compared with GOD-LMCHI/PT (9.8579 nA/mM glucose) at S/N>3. Better repeatability and reproducibility were achieved with GOD-MMCHI/PT than GOD-LMCHI/PT regarding glucose measurement. GOD-MMCHI/PT was found to give the highest enzymatic activity among the electrodes under investigation. The extent of interference encountered by GOD-MMCHI/PT and GOD-LMCHI/PT was not significantly different. Although the Nafion coated biosensor significantly reduced the signal due to the interferents under study, it also significantly reduced the response to glucose. The performance of the biosensors in the determination of glucose in rat serum was evaluated. Comparatively better accuracy and recovery results were obtained for GOD-MMCHI/PT. Hence, GOD-MMCHI/PT showed a better performance when compared with GOD-LMCHI/PT. In conclusion, chitosan membranes shave the potential to be a suitable matrix for the development of glucose biosensors.
引用
收藏
页数:13
相关论文
共 36 条
[1]   Molecular weight and degree of deacetylation effects on lipase-loaded chitosan bead characteristics [J].
Alsarra, IA ;
Betigeri, SS ;
Zhang, H ;
Evans, BA ;
Neau, SH .
BIOMATERIALS, 2002, 23 (17) :3637-3644
[2]  
BERGMEYER HU, 1974, METHOD ENZYMAT AN, P1205
[3]   Aqueous sol-gel process for protein encapsulation [J].
Bhatia, RB ;
Brinker, CJ ;
Gupta, AK ;
Singh, AK .
CHEMISTRY OF MATERIALS, 2000, 12 (08) :2434-2441
[4]   Immobilization of horseradish peroxidase on chitosan for use in nonaqueous media [J].
Bindhu, LV ;
Abraham, ET .
JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 88 (06) :1456-1464
[5]   A noninterference polypyrrole glucose biosensor [J].
Chen, Cheng ;
Jiang, Yan ;
Kan, Jinqing .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (05) :639-643
[6]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[7]  
Dhanikula AB, 2004, AAPS J, V6
[8]   Utilization of enzyme-substrate interactions in analytical chemistry [J].
Freitag, R .
JOURNAL OF CHROMATOGRAPHY B, 1999, 722 (1-2) :279-301
[9]   VALIDATION OF BIOANALYTICAL METHODS [J].
KARNES, HT ;
SHIU, G ;
SHAH, VP .
PHARMACEUTICAL RESEARCH, 1991, 8 (04) :421-426
[10]   FOURIER SELF-DECONVOLUTION - A METHOD FOR RESOLVING INTRINSICALLY OVERLAPPED BANDS [J].
KAUPPINEN, JK ;
MOFFATT, DJ ;
MANTSCH, HH ;
CAMERON, DG .
APPLIED SPECTROSCOPY, 1981, 35 (03) :271-276