Biomechanical comparison of the All-on-4, M-4, and V-4 techniques in an atrophic maxilla: A 3D finite element analysis

被引:15
作者
Ayali, Aysa [1 ]
Altagar, Mazen [1 ]
Ozan, Oguz [2 ]
Kurtulmus-Yilmaz, Sevcan [2 ]
机构
[1] Near East Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Mersin 10, Nicosia Cyprus, Turkey
[2] Near East Univ, Fac Dent, Dept Prosthodont, Mersin 10, Nicosia Cyprus, Turkey
关键词
Dental implant; All-on-four; Angulated implants; Immediate rehabilitation; Primary stability; FEA; DENTAL IMPLANTS; DIAMETER; BONE;
D O I
10.1016/j.compbiomed.2020.103880
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Patients with severely atrophied jaws can be challenging in implantology. The All-on-4 treatment concept eliminates advanced augmentation procedures in highly resorbed ridges by preserving the relevant anatomic structures. In addition, the inclination of the distal implants enables the placement of longer implants. Hence, tilting the anterior implants allows longer implant placement, in line with the distal implants of the All-on-4 concept. This study compared the biomechanical aspects of the standard All-on-4 treatment concept with the M-4 and V-4 techniques. Methods: A three-dimensional model of an edentulous maxilla was created to perform three-dimensional finite element analysis. Three different configurations (All-on-4, M-4, and V-4) were modeled by changing the tilt angle of the anterior implants. In each model, to simulate a foodstuff, a solid spherical material was placed on the midline of the incisors and the right first molar region, separately applying an occlusal load of 100 Newtons. The maximum principal stress and minimum principal stress values were acquired for cortical bone, and von Mises stress values were obtained for ductile materials. Results: According to the present study's findings, although there were no considerable differences among the models, in general, the All-on-4 group demonstrated slightly higher stresses and the M-4 and V-4 group showed lower stresses. Conclusion: M-4 or V-4 configurations may be used in cases of severely atrophied anterior maxillae to achieve better primary stabilization.
引用
收藏
页数:10
相关论文
共 27 条
[1]   Three-Dimensional Finite Element Analysis of Different Plating Techniques for Unfavorable Mandibular Angle Fractures [J].
Ayali, Aysa ;
Erkmen, Erkan .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (03) :603-607
[2]   Biomechanical Evaluation of Different Plating Methods Used in Mandibular Angle Fractures With 3-Dimensional Finite Element Analysis: Favorable Fractures [J].
Ayali, Aysa ;
Erkmen, Erkan .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (07) :1464-1474
[3]   Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis [J].
Ayali, Aysa ;
Bilginaylar, Kani .
HEAD & FACE MEDICINE, 2017, 13
[4]  
Barikani Hamidreza, 2013, J Dent (Tehran), V10, P449
[5]  
Bataineh Anwar B, 2017, J Clin Exp Dent, V9, pe1, DOI 10.4317/jced.53302
[6]   Treatment Planning the Edentulous Mandible. Review of Biomechanical and Clinical Considerations: An Update [J].
Bedrossian, Edmond ;
Bedrossian, E. Armand .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) :E33-E41
[7]   10-YEAR SURVIVAL RATES OF FIXED PROSTHESES ON 4 OR 6 IMPLANTS AD-MODUM BRANEMARK IN FULL EDENTULISM [J].
BRANEMARK, PI ;
SVENSSON, B ;
VANSTEENBERGHE, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :227-231
[8]   Biomechanical effects of implant number and diameter on 0 stress distributions in maxillary implant-supported overdentures [J].
Dimililer, Gizem ;
Kucukkurt, Sercan ;
Cetiner, Sedat .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (02) :244-249
[9]  
Gallucci GO, 2009, INT J ORAL MAX IMPL, V24, P132
[10]   Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study [J].
Gumrukcu, Zeynep ;
Korkmaz, Yavuz Tolga ;
Korkmaz, Fatih Mehmet .
COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 86 :47-54