TPH and PAH concentrations in the subsoil of polyduct segments, oil pipeline pumping stations, and right-of-way pipelines from Central Mexico

被引:8
作者
Iturbe, Rosario [2 ]
Castro, Alejandrina [2 ]
Perez, Guillermina [2 ]
Flores, Carlos [2 ]
Torres, Luis G. [1 ]
机构
[1] UPIBI, Natl Politechn Inst, Bioprocess Dept, Mexico City 07340, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Engn Inst, Dept Environm Engn, Remediat Soils & Aquifers Grp, Mexico City 04510, DF, Mexico
来源
ENVIRONMENTAL GEOLOGY | 2008年 / 55卷 / 08期
关键词
Mexico; PAH; pipelines; polyduct; right of way; TPH;
D O I
10.1007/s00254-007-1129-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For the year 1996, 366 incidents related with clandestine poaching of oil-products were reported in Mexico, 159 in 1997, and 240 in 1998. For the year 2003 (the most recently reported figure), there were 136 events. Petroleos Mexicanos (PEMEX), very concerned with the environmental agenda, has developed programs oriented to diminish contamination levels in all of its oil facilities. This work was aimed at characterizing zones around polyduct segments, pipelines, pumping stations, and right-of-way pipelines located in the center of Mexico. The TPH contaminated sites were, in decreasing order, polyduct km 39 + 150 > polyduct km 25 + 020 > Zoquital > Tepetitlan > Catalina > Venta Prieta > Ceiba. Most of the sampled points showed the presence of more than one of the 16 PAHs considered by USEPA as priority pollutants. Except point TEPE 2A, where no PAHs were detected, all the sampled points showed values from low to medium concentrations; however, values found at the sites did not exceed the limits according to the Mexican or the American legislation. The place with the largest contaminated area corresponded to the polyduct km 39 + 150, with 130 m(2) and 260 m(3) to be treated. The least contaminated area was that around the JUAN 4 point at Juandho station, with 20 m(2) and 22 m(3) of contaminated soil. The total area to be treated is about 230 m(2) and 497 m(3).
引用
收藏
页码:1785 / 1795
页数:11
相关论文
共 22 条
[1]  
*ASTM, 1993, C12893 ASTM
[2]  
CNA, 2002, DET DISP AG AC VALL
[3]  
FAHNESTOCK FM, 1998, BIOPILE DESIGN OPERA
[4]  
GAUGER, 2009, PREUBAS BIOTRATABILI
[5]  
*HIDR, 1970, EST GEOH VALL MEZQ Z
[6]   Cleanup levels at an oil distribution and storage station in eastern central Mexico determined from a health risk assessment [J].
Iturbe, R ;
Flores, RM ;
Flores, C ;
Torres, LG .
INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2006, 26 (1-3) :106-128
[7]   Subsoil TPH and other petroleum fractions-contamination levels in an oil storage and distribution station in north-central Mexico [J].
Iturbe, R ;
Flores, C ;
Flores, RM ;
Torres, LG .
CHEMOSPHERE, 2005, 61 (11) :1618-1631
[8]   TPH-contaminated mexican refinery soil: Health risk assessment and the first year of changes [J].
Iturbe, R ;
Flores, RM ;
Flores, CR ;
Torres, LG .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2004, 91 (1-3) :237-255
[9]   Subsoil contaminated by hydrocarbons in an out-of-service oil distribution and storage station in Zacatecas, Mexico [J].
Iturbe, R ;
Flores, RM ;
Torres, LG .
ENVIRONMENTAL GEOLOGY, 2003, 44 (05) :608-620
[10]   Soil and water contamination levels in an out-of-service oil distribution and storage station in Michoacan, Mexico [J].
Iturbe, R ;
Flores, RM ;
Torres, LG .
WATER AIR AND SOIL POLLUTION, 2003, 146 (1-4) :261-281