Optical biometry of eyes corrected by phakic intraocular lenses

被引:9
作者
Pitault, G [1 ]
Leboeuf, C [1 ]
Jardins, SLL [1 ]
Auclin, F [1 ]
Chong-Sit, D [1 ]
Baudouin, C [1 ]
机构
[1] Ctr Hosp Natl Ophthalmol Quinze Vingts, Serv Ophtalmol 3, F-75012 Paris, France
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2005年 / 28卷 / 10期
关键词
biometry; IOL master; phakic intraocular lens; cataract;
D O I
10.1016/S0181-5512(05)81137-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to determine whether eye length measurements obtained with the IOL Master((R)) (Zeiss Humphrey) before and after phakic IOL implantation would show any changes. Methods: In a prospective study, we used the IOL Master((R)) to measure optical biometry in 25 myopic eyes of 15 patients before and after phakic IOL implantation (PRL(TM), ICL (TM), Artisan (TM)). The differences between both axial length measurements were calculated and compared using a nonparametric Wilcoxon test. Results: The difference between the preoperative and postoperative measurements ranged from -0,16 mm to 0,06 mm and averaged -0,016 mm, which was not statistically significant (p = 0.20). Both measurements correlated in a highly positive manner (r = 0.999; p < 0.0001). The reproducibility of the preoperative and postoperative axial length measurements was very high (coefficient of variation = 0.09% and 0.07%, respectively). The precision was 26 mu m for preoperative measurements and 19 lurn for postoperative measurements. Conclusion: Our results showed that postoperative measurements of axial length are highly comparable to preoperative measurements and that optical biometry can achieve highly precise and reliable axial length measurements in eyes with phakic IOLs. This application becomes clinically relevant in evaluating eyes with phakic IOLs that might require cataract surgery. Hence, accurate axial length measurements in eyes with phakic IOLs will be extremely important when cataract occurs in these eyes and when the preoperative measurements are no longer available.
引用
收藏
页码:1052 / 1057
页数:6
相关论文
共 24 条
  • [1] Bamber JC., 1988, PHYS MED IMAGING, P319
  • [2] Measurements of the posterior structures of the human eye in vivo by partial coherence interferometry using diffractive optics
    Baumgartner, A
    Moller, B
    Hitzenberger, CK
    Drexler, W
    Fercher, AF
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS, PROCEEDINGS OF, 1997, 2981 : 85 - 93
  • [3] B-mode-guided vector-A-mode versus A-mode biometry to determine axial length and intraocular lens power
    Berges, O
    Puech, M
    Assouline, M
    Letenneur, L
    Gastellu-Etchegorry, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (04) : 529 - 535
  • [4] Partial coherence interferometry: A novel approach to biometry in cataract surgery
    Drexler, W
    Findl, O
    Menapace, R
    Rainer, G
    Vass, C
    Hitzenberger, CK
    Fercher, AF
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) : 524 - 534
  • [5] High precision biometry of pseudophakic eyes using partial coherence interferometry
    Findl, O
    Drexler, W
    Menapace, R
    Hitzenberger, CK
    Fercher, AF
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (08) : 1087 - 1093
  • [6] FREUDIGER H, 1984, AM INTRA-OCUL IMPL J, V10, P29
  • [7] Pseudophakic correction factors for optical biometry
    Haigis, W
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (08) : 589 - 598
  • [8] Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    Haigis, W
    Lege, B
    Miller, N
    Schneider, B
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) : 765 - 773
  • [9] HITZENBERGER CK, 1991, INVEST OPHTH VIS SCI, V32, P616
  • [10] HOFFER KJ, 1981, ARCH OPHTHALMOL-CHIC, V99, P1819