A Perturbation Platform and Exoskeleton Simulator for Studying Balance Control of Hip Exoskeleton: Design and Preliminary Validation

被引:1
作者
Feng, Kaixiang [1 ]
Zhang, Ting [1 ]
机构
[1] Soochow Univ, Coll Mech & Elect Engn, Suzhou 215000, Peoples R China
来源
INTELLIGENT ROBOTICS AND APPLICATIONS (ICIRA 2022), PT III | 2022年 / 13457卷
基金
国家重点研发计划;
关键词
Hip exoskeleton; Perturbation platform; Series elastic actuator; Balance recovery;
D O I
10.1007/978-3-031-13835-5_11
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In order to deal with the problem of imbalance of the elderly in the process of walking on level ground, this paper proposes a hip exoskeleton with series elastic actuator (SEA) to assist the wearer to adjust the step width, step length and step frequency in real time during walking to maintain balance walking. Through the built multi-sensor fusion gait perturbation and perception integrated platform, the experimenter's autonomous recovery of balance experiment and exoskeleton-assisted human body's recovery of balance experiment under external wrench state were carried out respectively. The perturbations were applied in four directions to the experimenter while walking, which verified the validity of the balance evaluation model and the assisting effect of the exoskeleton in restoring the balance of human walking. Firstly, according to the established kinematics model, the displacement and velocity of the experimenter's center of mass during walking are calculated, and the system is simplified to a linear inverted pendulum model (LIPM) to evaluate the motion state. Secondly, a balance state evaluation model is established based on the instantaneous capture point (ICP) theory, and the balance state evaluation of the human body is realized by judging the positional relationship between the instantaneous capture point and the support range of the feet. Finally, according to the step strategy in the human body balance strategy, the magnitude of the auxiliary torque when the experimenter is out of balance is calculated through the relative position of the center of mass and the instantaneous capture point. Therefore, it can be shown that the balance evaluation model and exoskeleton control strategy we established can provide the balance restoring torque for the experimenter to swing the leg when the system is about to become unbalanced, which can effectively slow down the unbalanced trend.
引用
收藏
页码:113 / 126
页数:14
相关论文
共 14 条
  • [1] Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles
    del Carmen Sanchez-Villamanan, Maria
    Gonzalez-Vargas, Jose
    Torricelli, Diego
    Moreno, Juan C.
    Pons, Jose L.
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (1)
  • [2] CENTRAL PROGRAMMING OF POSTURAL MOVEMENTS - ADAPTATION TO ALTERED SUPPORT-SURFACE CONFIGURATIONS
    HORAK, FB
    NASHNER, LM
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1986, 55 (06) : 1369 - 1381
  • [3] On the Sensor Design of Torque Controlled Actuators: A Comparison Study of Strain Gauge and Encoder-Based Principles
    Kashiri, Navvab
    Malzahn, Jorn
    Tsagarakis, Nikos G.
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2017, 2 (02): : 1186 - 1194
  • [4] An ecologically-controlled exoskeleton can improve balance recovery after slippage
    Monaco, V.
    Tropea, P.
    Aprigliano, F.
    Martelli, D.
    Parri, A.
    Cortese, M.
    Molino-Lova, R.
    Vitiello, N.
    Micera, S.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [5] Population Division of the Department of Economic and Social Affairs of the United Nations Secretariat, 2019, 2019 REVISION WORLD
  • [6] Capture point: A step toward humanoid push recovery
    Pratt, Jerry
    Carff, John
    Drakunov, Sergey
    Goswami, Ambarish
    [J]. 2006 6TH IEEE-RAS INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS, VOLS 1 AND 2, 2006, : 200 - +
  • [7] Ergonomics of Exoskeletons: Objective Performance Metrics
    Schiele, Andre
    [J]. WORLD HAPTICS 2009: THIRD JOINT EUROHAPTICS CONFERENCE AND SYMPOSIUM ON HAPTIC INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS, PROCEEDINGS, 2009, : 103 - +
  • [8] Design of a Rotational Hydroelastic Actuator for a Powered Exoskeleton for Upper Limb Rehabilitation
    Stienen, Arno H. A.
    Hekman, Edsko E. G.
    ter Braak, Huub
    Aalsma, Arthur M. M.
    van der Helm, Frans C. T.
    van der Kooij, Herman
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (03) : 728 - 735
  • [9] Design and Characterization of an Exoskeleton for Perturbing the Knee During Gait
    Tucker, Michael R.
    Shirota, Camila
    Lambercy, Olivier
    Sulzer, James S.
    Gassert, Roger
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (10) : 2331 - 2343
  • [10] WINTER DA, 1995, GAIT POSTURE, V3, P193