Frameless image-guided stereotaxy with real-time visual feedback for brain biopsy

被引:47
作者
Gempt, Jens [1 ]
Buchmann, Niels [1 ]
Ryang, Yu-Mi [1 ]
Krieg, Sandro [1 ]
Kreutzer, Jurgen [1 ]
Meyer, Bernhard [1 ]
Ringel, Florian [1 ]
机构
[1] Tech Univ Munich, Dept Neurosurg, Klinikum Rechts Isar, D-81675 Munich, Germany
关键词
Frameless stereotaxy; Image guidance; Brain biopsy; Brain tumour; TECHNICAL NOTE; REGISTRATION; ACCURACY; ADVANTAGES; MORBIDITY; EFFICACY; SAFETY;
D O I
10.1007/s00701-012-1425-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Frame-based stereotaxy remains the "gold standard" for cerebral biopsies and functional neurosurgery though new frameless stereotactic systems are evolving continually. As the technique of frameless stereotaxy gains increasing acceptance among neurosurgeons, this study assesses the feasibility of a system for frameless image-guided stereotaxy. All patients biopsied for intracranial lesions between February 2007 and August 2010 using the BrainLAB VarioGuide frameless stereotactic system were evaluated prospectively. Prior to surgery, patients underwent magnetic resonance (MR) imaging; additionally, fluoroethyl-tyrosine (FET)-positron emission tomography (PET) images were acquired and fused to MR images in selected cases. Biopsy trajectory length, lesion volume, procedure duration, and diagnostic yield were assessed. Ninety-six diagnostic biopsies in 91 patients were evaluated. Lesion volume ranged from 0.17 to 121.8 cm(3); trajectory length from 25.3 to 101.9 mm. Diagnostic yield was 93.8%. Mean operation time from skin incision to wound closure was 42 min; in the operating room, it was 99 min. Clinical experience indicates VarioGuide to be safe and accurate. Reachable range of lesion localisation appears to be comparable to a frame-based stereotaxy system. Operation times are brief. The unique design of this frameless stereotactic system allows real-time visual feedback of needle positioning.
引用
收藏
页码:1663 / 1667
页数:5
相关论文
共 21 条
[1]   Frameless stereotaxy with scalp-applied fiducial markers for brain biopsy procedures: experience in 218 cases [J].
Barnett, GH ;
Miller, DW ;
Weisenberger, J .
JOURNAL OF NEUROSURGERY, 1999, 91 (04) :569-576
[2]   Safety and efficacy of frameless and frame-based intracranial biopsy techniques [J].
Dammers, R. ;
Haitsma, I. K. ;
Schouten, J. W. ;
Kros, J. M. ;
Avezaat, C. J. J. ;
Vincent, A. J. P. E. .
ACTA NEUROCHIRURGICA, 2008, 150 (01) :23-29
[3]   Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies - Technical note [J].
Dorward, NL ;
Alberti, O ;
Palmer, JD ;
Kitchen, ND ;
Thomas, DGT .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :160-168
[4]   The advantages of frameless stereotactic biopsy over frame-based biopsy [J].
Dorward, NL ;
Paleologos, TS ;
Alberti, O ;
Thomas, DGT .
BRITISH JOURNAL OF NEUROSURGERY, 2002, 16 (02) :110-118
[5]  
Germano I M, 1998, Comput Aided Surg, V3, P33, DOI 10.3109/10929089809148126
[6]   Frame-based and frameless endoscopic: Procedures in the third ventricle [J].
Grunert, P ;
Hopf, N ;
Perneczky, A .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 68 (1-4) :80-89
[7]  
Hall WA, 1998, CANCER, V82, P1749, DOI 10.1002/(SICI)1097-0142(19980501)82:9<1756::AID-CNCR23>3.0.CO
[8]  
2-2
[9]  
Heilbrun MP, 1988, C NEUR SURG STER NEU
[10]   STEREOTAXIC APPARATUS AND OPERATIONS IN RUSSIA IN 19TH CENTURY [J].
KANDEL, EI ;
SCHAVINSKY, YV .
JOURNAL OF NEUROSURGERY, 1972, 37 (04) :407-+