Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations

被引:13
作者
Geith, Markus A. [1 ,2 ]
Nothdurfter, Laurenz [1 ]
Heiml, Manuel [1 ]
Agrafiotis, Emmanouil [1 ]
Gruber, Markus [3 ]
Sommer, Gerhard [1 ]
Schratzenstaller, Thomas G. [4 ]
Holzapfel, Gerhard A. [1 ,5 ]
机构
[1] Graz Univ Technol, Inst Biomech, Stremayrgasse 16-11, A-8010 Graz, Austria
[2] Kings Coll London, Biomed Engn Dept, London, England
[3] SELMO GmbH, Dobl, Austria
[4] Tech Univ Appl Sci Regensburg, Regensburg Ctr Biomed Engn, Med Device Lab, Regensburg, Germany
[5] Norwegian Univ Sci & Technol, Dept Struct Engn, Trondheim, Norway
基金
奥地利科学基金会;
关键词
Percutaneous coronary intervention; Stent; Mechanical properties; Damage mechanism; Vascular injury; Coronary artery; Indentation test; Softening; Second-harmonic generation imaging; Micro-structure; BARE-METAL STENTS; NEOINTIMAL RESPONSE; ELUTING STENT; RESTENOSIS; INJURY; PATHOPHYSIOLOGY; COLLAGEN; STRESS; MODEL;
D O I
10.1016/j.actbio.2020.08.016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device 'LAESIO' that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:285 / 301
页数:17
相关论文
共 48 条
[1]   Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease [J].
Bonaa, K. H. ;
Mannsverk, J. ;
Wiseth, R. ;
Aaberge, L. ;
Myreng, Y. ;
Nygard, O. ;
Nilsen, D. W. ;
Klow, N. -E. ;
Uchto, M. ;
Trovik, T. ;
Bendz, B. ;
Stavnes, S. ;
Bjornerheim, R. ;
Larsen, A. -I. ;
Slette, M. ;
Steigen, T. ;
Jakobsen, O. J. ;
Bleie, O. ;
Fossum, E. ;
Hanssen, T. A. ;
Dahl-Eriksen, O. ;
Njolstad, I. ;
Rasmussen, K. ;
Wilsgaard, T. ;
Nordrehaug, J. E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (13) :1242-1252
[2]   Age-dependent ultrastructural changes of coronary artery in spontaneously hypertensive rats [J].
Cebova, Martina ;
Kristek, Frantisek .
GENERAL PHYSIOLOGY AND BIOPHYSICS, 2011, 30 (04) :364-372
[3]   Microstructure-based biomechanics of coronary arteries in health and disease [J].
Chen, Huan ;
Kassab, Ghassan S. .
JOURNAL OF BIOMECHANICS, 2016, 49 (12) :2548-2559
[4]   Biaxial deformation of collagen and elastin fibers in coronary adventitia [J].
Chen, Huan ;
Slipchenko, Mikhail N. ;
Liu, Yi ;
Zhao, Xuefeng ;
Cheng, Ji-Xin ;
Lanir, Yoram ;
Kassab, Ghassan S. .
JOURNAL OF APPLIED PHYSIOLOGY, 2013, 115 (11) :1683-1693
[5]   The Layered Structure of Coronary Adventitia under Mechanical Load [J].
Chen, Huan ;
Liu, Yi ;
Slipchenko, Mikhail N. ;
Zhao, Xuefeng ;
Cheng, Ji-Xin ;
Kassab, Ghassan S. .
BIOPHYSICAL JOURNAL, 2011, 101 (11) :2555-2562
[6]   Restenosis after carotid artery stenting [J].
Dai, Zhengze ;
Xu, Gelin .
VASCULAR, 2017, 25 (06) :576-586
[7]   Strain Uniformity in Biaxial Specimens is Highly Sensitive to Attachment Details [J].
Eilaghi, Armin ;
Flanagan, John G. ;
Brodland, G. Wayne ;
Ethier, C. Ross .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (09)
[8]   2.3: Biomechanical and Structural Quantification of Vascular Damage: A Unique Investigation of Stent Implantation [J].
Markus A. Geith ;
Gerhard Sommer ;
Thomas Schratzenstaller ;
Gerhard A. Holzapfel .
Artery Research, 2017, 20 (1) :50-50
[9]   On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests [J].
Geith, Markus A. ;
Swidergal, Krzysztof ;
Hochholdinger, Bernd ;
Schratzenstaller, Thomas G. ;
Wagner, Marcus ;
Holzapfel, Gerhard A. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (11)
[10]   Mechanistic evaluation of long-term in-stent restenosis based on models of tissue damage and growth [J].
He, Ran ;
Zhao, Liguo ;
Silberschmidt, Vadim V. ;
Liu, Yang .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) :1425-1446