Partial volume effect estimation and correction in the aortic vascular wall in PET imaging

被引:28
作者
Burg, S. [1 ]
Dupas, A. [2 ]
Stute, S. [3 ]
Dieudonne, A. [4 ]
Huet, P. [5 ]
Le Guludec, D. [1 ,2 ,6 ]
Buvat, I. [5 ]
机构
[1] Hop Bichat Claude Bernard, APHP Serv Med Nucl, F-75018 Paris, France
[2] INSERM, U698, F-75018 Paris, France
[3] CEA, Serv Hosp Frederic Joliot, F-91400 Orsay, France
[4] Hop Beaujon, APHP Serv Med Nucl, F-92110 Clichy, France
[5] IMNC, UMR 8165, CNRS, F-91400 Orsay, France
[6] Univ Paris 07, F-75013 Paris, France
关键词
POSITRON-EMISSION-TOMOGRAPHY; NUCLEAR-MEDICINE; ATHEROSCLEROSIS; VALIDATION; SIMULATION; PLAQUE; INFLAMMATION; ROBUSTNESS; PRINCIPLE; ONCOLOGY;
D O I
10.1088/0031-9155/58/21/7527
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We evaluated the impact of partial volume effect (PVE) in the assessment of arterial diseases with (18)FDG PET. An anthropomorphic digital phantom enabling the modeling of aorta related diseases like atherosclerosis and arteritis was used. Based on this phantom, we performed GATE Monte Carlo simulations to produce realistic PET images with a known organ segmentation and ground truth activity values. Images corresponding to 15 different activity-concentration ratios between the aortic wall and the blood and to 7 different wall thicknesses were generated. Using the PET images, we compared the theoretical wall-to-blood activity-concentration ratios (WBRs) with the measured WBRs obtained with five measurement methods: (1) measurement made by a physician (Expert), (2) automated measurement supposed to mimic the physician measurements (Max), (3) simple correction based on a recovery coefficient (Max-RC), (4) measurement based on an ideal VOI segmentation (Mean-VOI) and (5) measurement corrected for PVE using an ideal geometric transfer matrix (GTM) method. We found that Mean-VOI WBRs values were strongly affected by PVE. WBRs obtained by the physician measurement, by the Max method and by the Max-RC method were more accurate than WBRs obtained with the Mean-VOI approach. However Expert, Max and Max-RC WBRs strongly depended on the wall thickness. Only the GTM corrected WBRs did not depend on the wall thickness. Using the GTM method, we obtained more reproducible ratio values that could be compared across wall thickness. Yet, the feasibility of the implementation of a GTM-like method on real data remains to be studied.
引用
收藏
页码:7527 / 7542
页数:16
相关论文
共 29 条
[1]  
[Anonymous], 2011, R LANG ENV STAT COMP
[2]   Is 18F-Fluorodeoxyglucose Positron Emission Tomography Scanning a Reliable Way to Assess Disease Activity in Takayasu Arteritis? [J].
Arnaud, Laurent ;
Haroche, Julien ;
Malek, Zoulikha ;
Archambaud, Frederique ;
Gambotti, Laetitia ;
Grimon, Gilles ;
Kas, Aurelie ;
Costedoat-Chalumeau, Nathalie ;
Cacoub, Patrice ;
Toledano, Dan ;
Cluzel, Philippe ;
Piette, Jean-Charles ;
Amoura, Zahir .
ARTHRITIS AND RHEUMATISM, 2009, 60 (04) :1193-1200
[3]   Radioactive spheres without inactive wall for lesion simulation in PET [J].
Bazanez-Borgert, Marisa ;
Bundschuh, Ralph A. ;
Herz, Michael ;
Martinez, Maria-Jose ;
Schwalger, Markus ;
Ziegler, Sibylle I. .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (01) :37-42
[4]   Preliminary study of the detectability of coronary plaque with PET [J].
Delso, G. ;
Martinez-Moeller, A. ;
Bundschuh, R. A. ;
Nekolla, S. G. ;
Ziegler, S. I. ;
Schwaiger, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07) :2145-2160
[5]   A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology [J].
Erlandsson, Kjell ;
Buvat, Irene ;
Pretorius, P. Hendrik ;
Thomas, Benjamin A. ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :R119-R159
[6]  
Frouin V, 2002, J NUCL MED, V43, P1715
[7]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[8]   RUN-LENGTH ENCODINGS [J].
GOLOMB, SW .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1966, 12 (03) :399-+
[9]   PET FDG STUDIES IN ONCOLOGY [J].
HAWKINS, RA ;
HOH, CK .
NUCLEAR MEDICINE AND BIOLOGY, 1994, 21 (05) :739-747
[10]   GATE:: a simulation toolkit for PET and SPECT [J].
Jan, S ;
Santin, G ;
Strul, D ;
Staelens, S ;
Assié, K ;
Autret, D ;
Avner, S ;
Barbier, R ;
Bardiès, M ;
Bloomfield, PM ;
Brasse, D ;
Breton, V ;
Bruyndonckx, P ;
Buvat, I ;
Chatziioannou, AF ;
Choi, Y ;
Chung, YH ;
Comtat, C ;
Donnarieix, D ;
Ferrer, L ;
Glick, SJ ;
Groiselle, CJ ;
Guez, D ;
Honore, PF ;
Kerhoas-Cavata, S ;
Kirov, AS ;
Kohli, V ;
Koole, M ;
Krieguer, M ;
van der Laan, DJ ;
Lamare, F ;
Largeron, G ;
Lartizien, C ;
Lazaro, D ;
Maas, MC ;
Maigne, L ;
Mayet, F ;
Melot, F ;
Merheb, C ;
Pennacchio, E ;
Perez, J ;
Pietrzyk, U ;
Rannou, FR ;
Rey, M ;
Schaart, DR ;
Schmidtlein, CR ;
Simon, L ;
Song, TY ;
Vieira, JM ;
Visvikis, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4543-4561