Transient Instability Prediction Using Decision Tree Technique

被引:140
作者
Amraee, Turaj [1 ]
Ranjbar, Soheil [2 ]
机构
[1] KN Toosi Univ Technol, Dept Elect Engn, Tehran 1431714191, Iran
[2] Islamic Azad Univ, Sci & Res Branch, Tehran, Iran
关键词
Decision tree; out-of-step; power swing; prediction; transient stability; SUPPORT VECTOR MACHINES;
D O I
10.1109/TPWRS.2013.2238684
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a decision tree based method for out-of-step prediction of synchronous generators. For distinguishing between stable and out-of-step conditions, a series of measurements are taken under various fault scenarios including operational and topological disturbances. The data of input features and output target classes are used as the input-output pairs for decision tree induction and deduction. The merit of decision tree based detection of transient instability lies in robust classification of new unseen samples. The performance of the proposed method is verified on two test cases including a 9-bus dynamic network and the practical 1696-bus Iran national grid. The simulation results are presented for various input features and learning parameters.
引用
收藏
页码:3028 / 3037
页数:10
相关论文
共 18 条
[1]   Adaptive protection strategies for detecting power system out-of-step conditions using neural networks [J].
Abdelaziz, AY ;
Irving, MR ;
Mansour, MM ;
El-Arabaty, AM ;
Nosseir, AI .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (04) :387-394
[2]   Transient stability prediction by a hybrid intelligent system [J].
Amjady, Nima ;
Majedi, Seyed Farough .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) :1275-1283
[3]  
[Anonymous], 2002, POWER SYSTEM CONTROL
[4]   An adaptive out-of-step relay [J].
Centeno, V ;
Phadke, AG ;
Edris, A ;
Benton, J ;
Gaudi, M ;
Michel, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :61-71
[5]   A FAST APPROACH TO TRANSIENT STABILITY ESTIMATION USING AN IMPROVED POTENTIAL-ENERGY BOUNDARY SURFACE METHOD [J].
CHUNG, TS ;
FANG, DZ .
ELECTRIC POWER SYSTEMS RESEARCH, 1995, 34 (01) :47-55
[6]   OUT-OF-STEP DETECTION BASED ON PATTERN-RECOGNITION [J].
ELARABATY, AM ;
TALAAT, HA ;
MANSOUR, MM ;
ABDELAZIZ, AY .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1994, 16 (04) :269-275
[7]  
ESPOSITO F, 1993, P EUR C MACH LEARN, P165
[8]   Decision Trees Using Synchronized Phasor Measurements for Wide-Area Response-Based Control [J].
Gao, Qun ;
Rovnyak, Steven M. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (02) :855-861
[9]   Transient security assessment using multivariate polynomial approximation [J].
Jayasekara, B. ;
Annakkkage, U. D. .
ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (5-6) :704-711
[10]  
Kundur P., 1993, Power System Stability And Control