Ultra high molecular weight polyethylene (UHMWPE) wear debris has been shown to be a major cause of long term failure of total joint replacements. Recently, crosslinking has been extensively introduced to reduce the wear of UHMWPE. In this study the wear of non-crosslinked and crosslinked UHMWPE were compared under a range of conditions. The materials examined were UHMWPE GUR 1050, non-crosslinked, moderately crosslinked-5MRad, and highly crosslinked-10MRad. The wear was examined on a multidirectional pin on plate rig. The effect of counterface roughness on wear under different kinematics was examined. The results from the different counterface conditions showed that highly crosslinked UHMWPE had significantly lower wear against both smooth and scratched counterfaces. However the reduction in wear for crosslinked polyethylene was less for scratched counterfaces. The second part of the study showed that all the UHMWPE's produced lower wear rates under lower multidirectionality because of reduced cross shear frictional forces and work. These findings are relevant to the consideration of the use of crosslinked polyethylene in the knee, where the kinematics have lower levels of cross shear and in the hip and knee against roughened metallic counterfaces.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 18 条
[1]  
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[2]   A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[3]  
BARBOUR PSM, 1999, DTIC CAM PROJECT ACC
[4]   The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty [J].
Bennett, D ;
Orr, JF ;
Beverland, DE ;
Baker, R .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) :393-402
[5]   Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses [J].
Endo, M ;
Tipper, JL ;
Barton, DC ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H2) :111-122
[6]  
Endo MM, 2001, BIO-MED MATER ENG, V11, P23
[7]  
Fisher J., 1994, CURR ORTHOPAED, V8, P164, DOI DOI 10.1016/0268-0890(94)90048-5
[8]  
Green TR, 2000, J BIOMED MATER RES, V53, P490, DOI 10.1002/1097-4636(200009)53:5<490::AID-JBM7>3.0.CO
[9]  
2-7
[10]  
MCEWEN HMJ, 2002, THESIS U LEEDS